SMC Corporation of America
Elite Part Number Search
Search Results "ANA1-14"

16 14 17 13 14 13 14 MLU 6.5 6.5 5.5 7 8 ML1C 5 5 5 3.5 3.5 D4.5 4.5 4.5 4 4 -X 7 6.5 6.5 6 5 2011 10 10 9 9 4.5 4 4.5 4 4 Data Since this is a guideline including hysteresis, not meant to be guaranteed.

N2 NB NDh8 S SW WH XB ZZ 116 Bore 26 0 0.033 32 40 20 24 42.3 52.3 12 14 37.5 46.5 G1 /8 G1 /4 22 27 36 40 10 12 47 58.5 21 26 30 38 29 38 17 22 34.5 42.5 80 105 17 19 16 16 28 31 M10 x 1.5 9, 14 depth of counter bore 10 32 0 0.039 M12 x 1.75 11, 17.5 depth of counter bore 12.5 145 Rubber cushion: C76RBY Without magnet, Built-in magnet Bore Stroke B S + Stroke ZZ + Stroke (mm) AM 20 24 C

Q ZP T 10 06 31.8 10 6 4.5 08 35.9 14 8 6 20 30 50 40 50 A14 06 19.9 12 6 3 08 24.9 14 8 Width across flats P N N Dimensions Per Vacuum Inlet: Barb Fitting Model N P Fitting part min. hole size Vacuum inlet direction q Pad dia.

0 0.039 M12 x 1.75 11, 17.5 depth of counter bore 12.5 145 Rubber cushion: C76RBY Without magnet, Built-in magnet Bore Stroke B S + Stroke ZZ + Stroke (mm) AM 20 24 NDh8 C 12 14 D 37.5 46.5 EE G 1/8 G 1/4 F 42.4 52.4 FF M6 x 1 depth 11 M8 x 1.25 depth 14 FX 30 36 G1 22 27 H 36 40 K 10 12 KK M10 x 1.5 M12 x 1.75 N1 29 38 N2 17 22 NB 34.5 42.5 S 80 105 SW 17 19 WH 16 16 ZZ 116 145 Bore 26

(mm) DQ HQ HP 4 6 8 10 13 16 20 25 32 40 50 10 16 25 40 6 8 10 13 16 20 25 32 40 50 2.6 4.8 31 12 7 26 10 7 31 12 9 26 10 9 10 10 26 26 2.6 4.8 32 13 7 32 13 9 DQ HQ HP ZP ZC(D)UKD16 ZC(D)UKR16 12 12 31 31 15 12 33 18 16 37 28 20 44 DQ HQ HP 12 18 12 15 36 15 18 20 41 12 16 37 ZC(D)UKD20 ZC(D)UKR20 ZP 12 33 12.5 18.5 33.5 23 14 38 39.5 28 14 38 34 29 53 35 22 27 24 48 DQ HQ HP ZC(D)UKD25

Thread NPT Hex Part Number D1 Weight (grams) Bag/Box Quantity D2 D3 D4 L1 5/32 5/32** 1/4 1/4 1/4 1/4** 3/8 3/8 3/8 3/8 1/2 1/2 1/2 1/2** 5/8 5/8 5/8** 3/4 3/4** 1/8-27 1/4-27 1/8-27 1/4-18 3/8-18 1/2-14 1/8-27 1/4-18 3/8-18 1/2-14 1/4-18 3/8-18 1/2-14 3/4-14 3/8-18 1/2-14 3/4-14 1/2-14 3/4-14 KV2L03-34S KV2L03-35S KV2L07-34S KV2L07-35S KV2L07-36S KV2L07-37S KV2L11-34S KV2L11-35S KV2L11-36S

SOL.a Station 2 14 Station 1 SOL.b 14 1 SOL.a Station 1 1 SOL.a Station 1 SOL.a 1 The common polarity should be the same as the common specifications of the valve to be used.

19 24 26 26 20 22 28 40 40 30 40 50 60 60 12 16 19 24 34 34 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12.5 16.5 23.5 23.5 Bracket Combinations Bracket combination table -Refer to table together with combination drawings.

State (7): AL.14 report since 45 sec has elapsed since the circulating fluid temperature deviated, because it is outside the upper temperature monitoring range. TEMP OUT output ON. State (8): The alarm is reset manually, the temperature monitoring upper and lower limit range is out, so "AL.14", "AL.15" warning continue.

For the applicable auto switch to buffer, refer to page 8-5-14. It requires to order separately.

10 14 MB +0.070 0 0.1 0.3 12 16 24 50 M14 x 1.5 92 20 14 13 +0.070 0 0.1 0.3 12 16 69 22 24 55 M14 x 1.5 15.5 20 Double Knuckle Joint MB1 Y (Max.)

19 24 26 26 20 22 28 40 40 30 40 50 60 60 M10 x 1.25 16 19 24 34 34 M10 x 1.25 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12 M14 x 1.5 M14 x 1.5 12.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 CS1 23.5 23.5 C76 Bracket Combinations C85 Bracket Combinations Available Refer to table together

19 24 26 26 20 22 28 40 40 30 40 50 60 60 M10 x 1.25 16 19 24 34 34 M10 x 1.25 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12 M14 x 1.5 M14 x 1.5 12.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 CS1 23.5 23.5 C76 Bracket Combinations C85 Bracket Combinations Available Refer to table together

14 15 D-B59W 14 14 17 16 18 D-G5NB 35 35 40 40 40 D-G39/K39 D-G39C/K39C 9 9 10 10 11 D-P3DWA 4.5 4.5 5.5 5.5 5.5 D-P4DW 4 4 4.5 4 4.5 * Values which include hysteresis are for guideline purposes only, they are not a guarantee (assuming approximately 30% dispersion) and may change substantially depending on the ambient environment.

30 19 14 Up to 1400 Lube Non-lube Air-hydro 255 232 160 161 128 90 212 112 255 16 M14 x 1.5 98 1/2 M30 x 1.5 110 75 40 133 50 36 59 15 35 47 43 14 31 24 19 20 Up to 1400 0.2 x Stroke 273 252 40 180 182 144 90 236 118 275 18.5 M16 x 1.5 106 3/4 M36 x 1.5 120 75 141 56 40 59 17 39 53 43 36 14 26 19 20 Up to 1400 295 277 45 200 204 162 115 265 132 320 18.5 M18 x 1.5 111 3/4 M40 x 1.5 135 85

N.C.: Gray N.O.: Black B B B B B B B Dimensions Width across flats 14 1/8 Thread type/Rc, G: 10 One-touch fitting Thread type/NPT: 3/8" One-touch fitting Width across flats 14 1/8 M5 x 0.8 Applicable model AC25-B to AC60-B Optional/Semi-standard specifications Metal bowl Metal bowl with drain guide Metal bowl with level gauge Metal bowl with level gauge, with drain guide With drain guide

No.JXC-OMU0004-A (DC24V) / LECP1 Series 1. . 4 2. . 6 2.1 . 6 2.2 . 7 2.3 . 8 2.4 () . 9 1 . 9 2 . 9 3 . 9 4ON . 10 5(). 10 6 . 10 3. . 11 3.1 . 11 3.2 . 12 3.3 . 13 3.4 . 14 1 . 14 2 . 14 3 . 15 4. . 16 4.1 CN1 . 16 4.2 CN2CN3: . 16 4.3 CN4I/O . 16 5. CN . 17 5.1 . 17 5.2 . 17 (1) . 17 (2) . 18 (3) . 18 6.

18 Interface cable 7 9 8 Power cable 14 Power cable b View b View a a Wiring Signal description Cable description Color Pin no.