Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
ZS-35-C X X X X X E ZS-35-D X X ZS-35-F X X X X X + F ZS-35-G X X 1/ 1 ZS-24-A A M35 L,M45 L 2 ZS-24-B B M45 L, 2 ZS-24-D D M35 L,M45 L 2 ZS-35-C (01,N01) ZS-35-D (W1,WF1,M5,C4,C6) ZS-35-F +(01,N01) ZS-35-G +(W1,WF1,M5,C4,C6) -10No.PS-OMM0006CN-E M8(3 ) 01 N M L ISE40A 1/ 2 ISE40A -0.11.000 MPa Y ZSE40A 0.0-101.3 kPa K + T + 1 01 R1/8(M5) N01 NPT1/8(M5) A A D D N NPN1
42/for base mounted type (Port A side ported) How to Order Applicable solenoid valves VKF334Applicable blanking plate assembly VK300-42-1A VV3KF3 05 01 42 Solenoid direction Port size Rc(PT) 1/8 4 cassette 6 cassette 01 C4 C6 Solenoid on side opposite port A Nil Port P: Rc(PT) 1/8 Port R: Rc(PT) 1/8 Port A: Rc(PT) 1/8 Solenoid on same side as port A S Type S42 (solenoid on same side as port
Please contact SMC regarding the supply of digital pressure switch with unit conversion function. 794 Precision Regulator IR1000-A/2000-A/3000-A Series How to Order 0 0 0 IR 1 01 BG r t y u e w q A ARJ Option/Semi-standard: Select one each for a to e. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
PSE56-C01 24 B PSE56-A2 A B Model 8.2 12 9.2 12.2 15.5 9.5 A PSE56-01 PSE56-02 PSE56-N01 PSE56-N02 PSE56-C01 PSE56-A2 PSE56-B2 R 1/8 R 1/4 NPT 1/8 NPT 1/4 Rc 1/8 URJ 1/4 TSJ 1/4 24 B PSE56-B2 A 24 B 16-3-28 7 Series PSE Specific Product Precautions 1 Be sure to read before handling. Pressure Sensor Handling Air Supply Warning Warning ZSE ISE 1.
A A A A A R Y + Stroke R Y + Stroke 2-Rc 1/8 (Both sides) HU Width across flats HT 2-Rc 1/8 (Both sides) HU Hs CL View A-A CL R Y CL HT HU Bore size (mm) 20 25 32 40 50 63 80 100 14 108 49 14 30.7 14 108 54 14 33.2 14 110 64 14 36.5 15 121 77 14 41 16 136 92 17 46.2 16 139 100 17 53.2 23 165 115 23 62.2 23 165 140 26 72.7 Specifications other than above are the same as standard type.
B A HS 056 HS B A B A 075, 106 HS B A B A 150, 200, 250 Note 1) Figures in the table below are references for auto switch mounting positions in the stroke end detection.
Options: V1, Comparator, V2 V1 and V2 can be set to the following values: DirectSet (-32768 to +32767) Analog IN (Input #, 0 10 Volt) FB Value (Setting, Current) The Comparator can be: <, >,<=, >=, =, <> Input: I> (Input) Output: ON/OFF 6.12 The OFFSET Block This block is used to adjust an Analog Input value according to the following equation: Y = A/B*x + C Y = the nal Output value A and
S07B5 4(A) 2(B) 5(R1) 3(R2) 1(P) 5 (R1) 4 (A) 1 (P) 2 (B) 3 (R2) y t N.O. + N.O. Component Parts S07C5 2(B) No.
SYA w (B) 2 (A) 4 (A) 4 (B) 2 w y SYJA 1 (P) (EB)3 5(EA) VFA3000 VFA5000 VZA t (A)4 2(B) 3 (EB) 5 (EA) 1 (P) 5 (EA) 3 (EB) 1 (P) VFA VFA r y 1 (P) (EA)5 3(EB) VFRA 2 position double VPA4 Symbol 2 position double SYJA r t q q VFA1000 (B)2 4(A) w w (A) 4 (B) 2 (A) 4 (B) 2 VZA 5(EA) 1 (P) (EB)3 VTA VFA3000 VFA5000 2(B) (A)4 VGA 3 (EB) 5 (EA) 1 (P) 1 (P) 5 (EA) 3 (EB) t r (EA)5 1 (P) 3(EB) VPA
Double acting Enter together in order counting from station 1 on the left side, with the A (OUT) ports in front. Dimensions LLCA--C Stations 4-Mounting hole for W Y A K D L3 L2 L1 (Max.
Y . u , E 37 | 1/2" NPT M6 0 t 02 03 04 M 6 x 1 . 0 PT1/8 Pr1/4 PT3V8 PT1/2 a a a a a o a a a a a a a a a a a o a a a a a a a a a a a o a a a a a a a a a a a r a a a a a a a r a a a a a a a a o a r a o a a a The use of compact spacer with bracket reduces the total assembled space.
1wo e t i y u !4 !5 !2 q o !7 r !3 o r !0 w u t y !2 !3 !1 q i !4 e Meter-in type Meter-in type AS ASP ASN AQ ASV AK ASS ASR ASF Component Parts: Elbow Type Component Parts: Universal Type No. Description Material Note Body A Handle Body B Needle Gasket Seat ring Lock nut U seal Cassette Seal O-ring O-ring O-ring No.
AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500
B A B A B A B A A A PWR 93.5 COM (35) 64.4 43.2 66 75 (40) series EX500 2 9 SI unit 4 x M4 mounting hole 8 7 6 5 4 3 2 1 n D side Stations U side C8 [3(R) EXH port] C8: 8 One-touch fitting M12 8-pin socket DIN rail clamp screw R R 0 62.5 3 3 60 1 X X 40.5 B B B B B B B B 12 12 22.2 P P 25 1 1 A A A A A A A A 18.5 7.5 9.5 (12) (7.5) M12 8-pin plug C8 [1(P) SUP port] C8: 8 One-touch fitting
(L4) (L3) L2 L1 27 P = 10.5 8.8 28 (5.25) Applicable connector: Flat ribbon cable connector (20P) (Complies with MIL-C-83503) 23.5 63.5 13 (12) Indicator light Manual override 1.5 4.8 66 (5.5) (35) A A A B A B A B A B A 93.5 t y p e 40.5 4 x M4 mounting hole 35 2 52 D side U side Stations 8 7 6 5 4 3 2 1 n 61.5 C8 [3(R) EXH port] C8: 8 One-touch fitting DIN rail clamp screw R R 40.7 B X
(L4) (L3) L2 L1 27 P = 10.5 8.8 28 (5.25) Applicable connector: Flat ribbon cable connector (20P) (Complies with MIL-C-83503) 23.5 63.5 13 (12) Indicator light Manual override 1.5 4.8 66 (5.5) (35) A A A B A B A B A B A 93.5 t y p e 40.5 4 x M4 mounting hole 35 2 52 D side U side Stations 8 7 6 5 4 3 2 1 n 61.5 C8 [3(R) EXH port] C8: 8 One-touch fitting DIN rail clamp screw R R 40.7 B X
-ASD330F-01-08 10-ASD230F-M5-06 2.