AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.

VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil no. PVT317-001GBPVT317-G PVT317-001GB-L06 PVT317-G-06 PVT317-001CBPVT317-C Coil assembly with terminal part no.

When the zero cut-off function is set to 0, the flow rate display value starts from 0 L/min., but in conditions other than horizontal installation and supply pressure of 0.35 MPa, the output may not be 0 L/min. 13 E F G PF2M701/02/05 /10/50/11/21(-L) PF2M725(-L) Voltage output (0 to 10 V)*1 0 V 0.10 V 0.12 V 10 V Output Output C G D H B F A E 0 0 Min. value of Flow Zero cut-off Max. value

Description POM Valve 19033 19014 19024 e Stainless steel Spring 19037 19015 19025 r NBR O-ring 20 x 17 x 1.5 t NBR Ring 19016 19026 y Brass, NBR Seat ring 19013 19023 u Dimensions Model Port size L1 H B AK2000-01/02 22 25 1/8, 1/4 50 AK4000-02/03/04 36 36 1/4, 3/8, 1/2 67 AK6000-06/10 50 50 3/4, 1 95 Caution Be sure to read before handling.

COMP.T H No.9 Display in the range of 0 to 1,000,000 screen Accumulated operation time of fan FAN.T H No.10 Display in the range of 0 to 1,000,000 screen Used time of dust filter 1 FLTR.T H No.11 Display in the range of 0 to 1,000,000 screen Used time of DI filter 2 DI.T H No.12 Display in the range of 0 to 1,000,000 screen Instantaneous power failureoccurrence count POW.F No.13 Display

COMP.T H No.9 Display in the range of 0 to 1,000,000 screen Accumulated operation time of fan FAN.T H No.10 Display in the range of 0 to 1,000,000 screen Used time of dust filter 1 FLTR.T H No.11 Display in the range of 0 to 1,000,000 screen Used time of DI filter 2 DI.T H No.12 Display in the range of 0 to 1,000,000 screen Instantaneous power failureoccurrence count POW.F No.13 Display

: 01) EVS1-02 (Size: 02) 100 80 1000 l/min (ANR) 400 l/min (ANR) Accommodates enclosure IP65 Dust/Splashproof type Lightweight Size 01 (3 position): 0.26 kg Size 02 (3 position): 0.18 kg 3-11-11 12 ISO Standard Solenoid Valve Size 1,2/Single Unit Series EVS1-01/1-02 How to Order FG S EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 Courtesy of Steven Engineering, Inc

ECO F RUN MPa ALM PSI WRN LPM GPM Lighting up RUN MPa ALM M RMT WRN LPM H RUN EXT SEC RMT H AT SEC MENU RUN/ MENU RUN/ STOP STOP ENT Press and hold for approximately 1second.

AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 Adjustment of Cushion Effect (Smooth Start-up, Soft Stop) Caution Since the external slider and piston slider are directional for size 10, refer to the drawings below when performing disassembly or maintenance.

AI Inlel pressure 0.7MPa /71 kgf/cm21 , outlel pressure 0.2MPa 1 2.0kgflcm21. flow rale 20 / min (ANR) AR2001-02 AR2001-02 0.25 -r-=:: lf~1 ~ "'" ~ :'.. ::;; 0.2 ~r. " 5 OJ> ~ o . 3k-1-j.-:=.

F Symbol 02 Note Stations 2 stations NKE Corp.: Fieldbus H System H Double wiring Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 outputs) 08 02 J1 8 stations SUP/EXH block fitting type 2 stations Specified layout Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 outputs) Nil L B Straight J2 (Up to 16 solenoids possible.)

-R -W N L ZZ + Stroke LS + Stroke N L CBM2G Bore size Stroke A Head flange: * -H -R -W Rod flange: CBM2F Bore size Stroke A * -H -R -W N L Z + Stroke Single clevis: CBM2C Bore size Stroke A -H -R -W N L Double clevis: CBM2D Bore size Stroke A -H -R -W N L ZZ + Stroke Z + Stroke + 1.2 0 + 1.2 0 ZZ + Stroke Z + Stroke + 1.2 0 + 1.2 0 CBM2U Bore size Stroke A Rod trunnion: * -H -R -W N

2 position double: VQ525 3 position closed center: VQ535 3 position exhaust center: VQ545 3 position pressure center: VQ555 3 position double check: VQ565 0 1 0 1 0 1 0 1 G H G H G H G H 194.5 (200) 121.3 53 73.2 (78.7) Indicator light 213 121.3 91.5 13.5 (Port B) 59.5 53 (Port A)17.5 13.5 (Port B) 59.5 (Port A) 17.5 Indicator light SMC 2 4 2 4 SMC A B A B 53 40 66 162 50 41 37 31.5 18 53

Nil R Internal pilot External pilot R U S Z NS NZ For K and H, mounting screws do not fall out from the valve.

Press the SET button while pressing the H button. The display holds the value accumulated up to now and stops. To start further accumulation from this point, press the SET button while pressing the H button. The display can be cleared by pressing the G button and the H button simultaneously for 2 seconds or more.

Use tap water that conforms to the standards shown below (including water used for dilution of ethylene glycol aqueous solution). 4 h HEA 2 h 1 h 30 min 20 min 14 min 10 min IDH 6 min 4 min Tap Water (as Circulating Fluid) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water 2 min Operating

Conversion factor: kcal/h to kW : 860 [(cal/h)/W] HRSE * Refer to the following for the typical physical property values by circulating fluid.