(L4) (L3) (5.25) L2 Top entry port Not machined 27 L1 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A
(L4) (L3) (5.25) L2 Top entry port Not machined 27 L1 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A
A A A A A Note) For details of the applicable tubing sizes, refer to page 945.
2 A A-A' Piston rod section A' !1 !3 !4 Component Parts Note Description Material No.
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
Power Valve: Economy Valve Series VEX5 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. Standard Specifications Model VEX5504 06 10 VEX5710 12 VEX5914 20 The conventional valve combination circuit has been condensed into a single valve.
Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006
B-1 2 L A A-1 1 B (B-2) 6 1 1.5m B (A-2) 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m (3) Shiel d Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 S B (B-6) 9 B (A-6) 8 3 (14.2) (2 ) 2 1 (8) (1 ) B1 A1 (14) (18) (17.7) 6 5 (3 ) 2 1 B6 A6 15 16 (11) (30.7) 15.2 [820m] (1) (2) -L A B-1 2 A A-1 1 B (B-2) 6 8 8m* B (A-2) 5 COM-A/COM B-3 3 A 10m* COM-B/ A-3 4 B 15m* (3) Shield
PB B A B A B A N.C. N.O. Double acting Double acting With flow rate adjustment PA PA N.C. B A PB B A Double acting N.C. Double acting With by-pass PA PA N.C. PB B A B A Double acting N.C. Double acting With flow rate adjustment & by-pass PA PA N.C. PB B A B A Double acting N.C.
AN120-M5 AS3001F-06 AN110-01 SY3120-C6 SY3140-01 T0604 x 1 m T0806 x 1 m AS3001F-06 T0604 x 1 m T0806 x 1 m AS3001F-08 AS3001F-06 SY5120-01 SY5140-02 AS3001F-08 AN101-01 AN101-01 T1075 x 1 m T0604 x 1 m T0604 x 1 m T1209 x 1 m T1075 x 1 m AS4001F-10 SY7120-02 SY7140-03 AS3001F-06 AS4001F-10 AS3001F-06 AN110-01 AN200-02 T0604 x 1 m T1075 x 1 m T1209 x 1 m T0604 x 1 m T1075 x 1 m T1209 x 1
RE A B Model Recommended Speed Controller REC Model Elbow type Straight type In-line type CX REC20 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REC25 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 CY REC32 AS2201F-01-06-X214 AS2301F-01-06-X214 AS3001F-08-X214 REC40 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way
Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.
ANm0m0-KMmm 5.2-4 40dB(A): High Noise Reduction Silencer Series ANA1 A high noice reduction style silencer keeps the noise level inside a plant below 85dB(A).
Symbol 0 A square plug set is normally used for the drain unit.
Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid
AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 AS-31B AS-32B AS-33B AS-34B AS-35B AS-36B AS-37B AS-38B AS-41B AS-42B AS-43B AS-44B AS-45B AS-46B AS-47B AS-48B AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11
A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
Symbol 0 A square plug set is normally used for the drain unit.
10 M6 x 1 Depth 7.5 39 50 0 77 74 59 155 128 143 3/4, 1 74 46 06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 5 Soft Start-up Valve AV2000/3000/4000/5000 Modular F.R.L.
A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12