Dimensions for Mounting of Auto Switch D-Z7/Z8 (Reed switch) D-Y5, D-Y6, D-Y7 (Solid state switch) A Dimension Bore size (mm) Auto switch model 10 15 20 25 32 6 A D-Y59A/Y7P/Y59B D-Y69A/Y7PV/Y69B D-Y7NWV/Y7PWV/Y7BWV D-Y7NW/Y7PW/Y7BW D-Y7BAL D-Z7, D-Z8 0.2 0.7 6.0 0.7 6.5 1.2 Mounting of Auto Switch When mounting and securing auto switches, they should be inserted into the cylinders switch
Basic style: CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G RE A B REC CX D E CY H1 MQQ M AL B1 K A N F N B C M S + Stroke H RHC ZZ + Stroke MK(2) RS Q G (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 RS H A B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92
500 Up to 600 Up to 600 Up to 700 Up to 700 RS H A B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22
(same side) D-Z73, Z76, Z80 Reed switch 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 60 D-Y59A(B), Y69A(B) Y7P(V) 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 70 D-Y7NW(V), Y7PW(V) Y7BW(V) Solid state switch 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
width across flats) AS-D AS-T ASP ASN AQ ASV AK Metric Size Inch Size VCHC Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) D3 L4 Max.
SD0 SDA1 SDA2 Serial kit without SI unit Serial kit for Remote I/O 1 to 8 stations (16 stations) FD0 FD1 FD2 FD3 D-sub connector kit (25P) without cable Serial unit: EX126 D-sub connector kit (25P) with 1.5 m cable 1 to 12 stations (24 stations) Serial kit for DeviceNet/PROFIBUS-DP/CC-LINK D-sub connector kit (25P) with 3.0 m cable P SDVB Serial kit for CC-LINK 1 to 8 stations (16 stations
for AC, since a rectifier prevents surge voltage generation. 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz)[115 VAC (50/60 Hz)] 4 220 VAC (50/60 Hz)[230 VAC (50/60 Hz)] 5 24 VDC 6 12 VDC Electrical entry D DIN terminal (Type D) With connector DO Without connector * DC specification of type D and DO is only available with 12 and 24 VDC.
CE2 ML2B ML1C Mounting Position (Stroke End)/Reed Switch Mounting Position (Stroke End)/Solid State Switch D-E73A (L), D-E76A (L), D-E80A (L) D-M5B (L), D-M5N (L), D-M5P (L) D-M5BW (L), D-M5NW (L), D-M5PW (L) D-M5NTL, D-M5PTL REA REC RHC MTS CC Lead wire clamp/Lead wire cap (option) Series Lead wire clamp Lead wire cap ML1C LC-01 LP-01 Unit: mm Lead wire clamp/Lead wire cap (option) 25 32
/M5W/M5TL D-E7A/E80A 25 6 4 32 6 4 D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
Range (mm) No. of auto switches mounted Applicable auto switch Bore size (mm) 25 6 4 D-M5, D-M5W, D-M5T D-E7A, D-E80A Auto switch model 40 6 4 D-M5, M5W, M5T D-E7A, E80A 32 6 4 10 15 5 10 1 pc. 2 pcs.
/M5W/M5TL D-E7A/E80A D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
Dimensions (mm) A B C D E F G K L M N P Model IDFA100F IDFA125F Port size R2 670 460 335 107 700 1120 1276 267 1375 20 712 752 R2 1/2 700 655 350 78 935 IDFA150F E D B 10 note) A G F C N M L K Note) In addition to the overall length of the body, the filter mounting part (bracket) projects 10 mm.
Two mounting styles Table traveling accuracy C D Bottom mount Top mount Model Traveling accuracy C side against A side D side against B side LG1H 0.1 or less 0.1 or less A B Variations Mounting orientation Lead screw type Motor type Guide type Motor/Screw connection Series Standard motor [Tamagawa Seiki Co., Ltd.]
Description (The gure shows the HRS-150-A-20.) q Hose (I.D.: 0.6 in [15 mm], Length: 27.5 in [700 mm]) Relief valve set pressure: 46 psi [0.32 MPa] (The relief valve starts to open when the circulating fluid discharge pressure reaches 46 psi [0.32 MPa] .)
HED q Hose (I.D.: 15 mm, Length: 700 mm) w Outlet piping assembly (With globe valve) Relief valve set pressure: 0.32 MPa (The relief valve starts to open when the circulating fluid discharge pressure reaches 0.32 MPa.)
Obtain the correction factors A to D suitable for your operating condition from the table on the next page.
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
3 Port Air Operated Valve VPA300/500/700 Series RoHS SYA SYJA VZA VFA VFRA VPA4 SYJA VZA VTA VGA VPA VPA VPA3 1555 VPA300/500/700 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm3/(sbar)] Type of actuation Port size Voltage Light/surge voltage suppressor Manual override Electrical entry VPA300 N.C. 2(A) 1/8 1/4 4.2 (P)1 3(R) VPA500
Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.
Nil M5 x 0.8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 TN NPT1/8 NPT1/8 NPT1/8 NPT1/4 TF G1/8 G1/8 G1/8 G1/4 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 d b C H B H 4 8 8 10 d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 B 14 26 32 41 C 16.2 30 37 47.3 Part number SNJ-016B SN-020B SN-032B SN-040B Applicable bore size (mm) 15 20 25, 32 40 161 Specific Product Precautions Be sure to read before handling.