SMC Corporation of America
Elite Part Number Search
Search Results "CXSJM10-50-M9N"

-CG1RN25 11-CG1RN32 11-CG1RN40 11-CG1RN50 11-CG1RN63 50 63 20 25 32 40 50 63 1/4 Non-lube Double acting, 25, 50, 75, 100, 125, 150 Single rod 25, 50, 75, 100, 125, 150, 200 1/8 25, 50, 75, 100, 125, 150, 200, 250, 300 1/4 Specifications Suction Flow Rate of Vacuum Suction Type (Reference values) Bore size (mm) Item 20 25 32 40 50 63 Size Suction flow rate L/min (ANR) 20/25/32/40 50/63 1.5

P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 10-4-7 8 Series CQ2Y Dimensions/63 to

26 28.5 33.5 M18 x 1.5 -X (mm) Without auto switch With auto switch A B A B 20U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5

J C A B DFull stroke -X 20Data eEntire stroke extension by pressurizing A, B and C ports. 10-10-1 2 3 Position Cylinder Series RZQ 32, 40, 50, 63 How to Order RZQ 32 200 100 A M9N Mounting style Number of auto switches A B L F G D Nil Both ends tapped 2 pcs.

50 63 14 14 14 17 17 20 50 50 56 63 63 71 47 47 53 60 60 67 1/4 1/4 1/4 3/8 3/8 1/2 17 17 20 23 25 30 36 36 40 45 50 60 59 59 59 70 74 86 43 43 43 48 48 60 15 15 17 20 20 25 31 31 36 41 46 56 19 19 22 26 26 30 145 75 18 110 136 115 25 90 90 90 115 115 140 16 107 58 110 M14 x 1.5 65 Up to 1000 3 5 30 46 +0.084 0 +0.100 0 0.1 0.3 161 78 18 110 146 128 28 16 114 64 110 M14 x 1.5 75 Up to

SU) S SF A AA YB effective depth YC 2 YA View (mm) AA A AU AV AW AX AY BA BB BC BD BE CA CB D DD DE DF DG FA FB FC FD H J JA JB Size 10 20 30 50 55.4 50 6.6 20 15.5 12 4 9.5 34.5 27.8 60 27 4.5 28.5 45h9 46h9 20H9 6 15H9 8 4 3 4.5 13 6.8 11 6.5 70.8 65 7.6 27.5 16 14 5 12 46 30 76 34 6 30.5 60h9 61h9 28H9 9 17H9 10 6 2.5 6.5 17 8.6 14 8.5 75.4 70 7.6 29 18.5 14 5 12 50 32 84 37 6.5 33.5 65h9

mm 190 30 MIS12-30D 30, 50 mm 300 10 MIS20-10D 20MIS 5 15 355 20 MIS20-20D Data 410 30 MIS20-30D 800 30 MIS25-30D 10 15 1000 50 MIS25-50D 1350 30 MIS32-30D 18 50 1650 50 MIS32-50D 10-11-9 9 Series MIW/MIS Construction: Double Finger Type (MIW) 8 12, 20 w i !

mm 190 30 MIS12-30D 30, 50 mm 300 10 MIS20-10D 20MIS 5 15 355 20 MIS20-20D Data 410 30 MIS20-30D 800 30 MIS25-30D 10 15 1000 50 MIS25-50D 1350 30 MIS32-30D 18 50 1650 50 MIS32-50D 10-11-9 9 Series MIW/MIS Construction: Double Finger Type (MIW) 8 12, 20 q y r !

71 43 19 14 190 230 15 M14x1.5,15 13 0125 Up to 1000 50 47 143 145 17 15 27 171 27 . t3 128 20 212 112 255 '15 'UpJo.1 QOO 50 47 157 1060 32 19 15 43 M14n.. ?

S Bore size Auto switch 20 20 mm Nil Without auto switch 25 25 mm For the applicable auto switch model, refer to the table below. 32 32 mm 40 40 mm 50 50 mm Action D Double acting Finger option Nil: Flat type fingers (Standard) 1: Right angle type fingers tapped mounting Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 0.5 40 8 0.5 Gripping force (N) Gripping force (N) 0.4 30 6 0.4 0.3 0.3 20 4 0.2 0.2 10 2 0.1 0.1 0 20 30 50 60 Gripping point L (mm) 40 0 30 40 60 70 Gripping point L (mm) 50 80 MHY2-16D MHY2-25D F F F F 35 100 Pressure 0.6 MPa Pressure 0.6 MPa 30 0.5 0.5 80 Gripping force (N) Gripping force (N) 25 External grip 0.4 0.4

+ 45 (n 2) (n = 2, 3, 4, 5) 10 15 50 D(n = 2, 4, 6) Note 3) 15 + 50 (n 2) 2 65 + 50 (n 2) (n = 2, 3, 4, 5) 10 15 65 15 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) 10 15 75 (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is an odd number, an even number that is one larger than this odd number is used for the calculation

(mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.

1 0 lo 1 00 Double rcd o12,o16/5llj30 o20 to o40l5 to 50 o50, 06311 0 to 50 Standaid Double acting Slngle rcd o12. 01615 to 30 o2Oa /5lo50 o32. s4015 lo lOO o50 to o 100/10 to 100 Double rod o i 2 , o 1 6 1 5 t o 3 0 a2O, o25l5Io 50 a32,64015lo lOO o50 to 010C/10to 100 Singleacting Sp ng retum/extend o 1 2 I o s 4 \ l 5 , 1 Q aslt1O.20 @eooy options @Auto switcn See catal N320 for avaibble

(mm) 50 63 80 / 1.5MPa 1.0MPa -1060() () 1.4 0 (Rc,NPT,G) 1/8 1/4 1/4 1-2. (N) 50 63 80 40.3 78.5 88.2 139.5 174.6 217.3 1-3. (mm) 50 30 63 30 80 40 1-4. (mm) (Kg) 50 1.70 / 63 2.78 80 4.96 4 - RS1H 1. mA 2. V(m/min) (Kg) 3.

L L H Holding point Holding point H MHF2-12D MHF2-8D 80 50 Pressure 0.2MPa 40 60 0.5MPa 0.5MPa Pressure 0.2MPa 0.6MPa 0.6MPa Overhang Hmm Overhang Hmm 0.7MPa 30 0.7MPa 0.3MPa 0.3MPa 40 0.4MPa 0.4MPa 20 20 10 40 20 80 60 40 20 0 0 50 30 10 Gripping point L mm Gripping point L mm MHF2-16D MHF2-20D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MHF2-12D 72.8 52 25 50 The low profile design saves space and reduces bending moments.

15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) D-H7m/H7mW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) D-C73C D-C80C D-H7C 10 15 65 15 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 27.5 (n 2) (n = 2, 3, 4, 5) D-M9mV 5 5 10 + 10 (n 2) (n = 4, 6) Note 4) D-A9mV 5 10 10 + 15 (n 2) (n = 4, 6) Note 4) D-M9m D-A9m 10