AS2002FS-06 When connecting 4 pcs. and mounting L-brackets on both sides AS-20A Speed controller AS2002FS-06 4 pcs. 3 111 2 L-bracket AS-20L 2 pcs.
port) One-touch fitting (A, B port) Applicable tubing O.D.: 4, 5/32" 1 (Pitch) P = 12.5 19.5 5 B B 15 1 A A 5 B B 15 20 A A L1 L2 4 Manual override + + + + 10 10 3.2 63.3 [65.5] 15.3 32 111.5 [115.9] 17 7.5 (4.4) 12.5 1 98.6[103] 16 A A A A A A R P R P 31.2 31.5 64.1 [66.3] 36.5 B B B B B B 65.3 17 50.5 70.3 2-4.5 (For mounting) + + + + + + Triangle mark 1/8 (P, R port) (Pitch) P = 12.5 18.5
ON-flow 0.04 40 B p ipe pe 3/4 B p pi 3B 30 1 0.03 2B, pipe 20 0.02 , 5B , 4B pe 1/4 1 B pi 10 Max.
Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I
, 07 01, 23, 03, 04, 06, 07 AS-F 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 TMH 400 200 06, 07 02 01, 23 ASD 300 50 03, 04 100 200 AS 01, 23 100 AS-FE 0 0 0 KE 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations AS-FG AS-FG Note) -U10/32 has the same specification as M5.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: H [Fiber (Honeycomb), Cotton Material], Nominal Filtration Accuracy: X50 (0.5 μm), Element Seal Material: Vessel Replacement or Fiber Element Types Only, Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 10 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 10 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 50 μm, Element Seal Material: Vessel Replacement or Fiber Element Types Only, Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 70 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: H [Fiber (Honeycomb), Cotton Material], Nominal Filtration Accuracy: 1 μm, Element Seal Material: Vessel Replacement or Fiber Element Types Only, Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 5 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: S (Sintered Metal, Stainless Steel Material), Nominal Filtration Accuracy: 100 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 10 μm, Element Seal Material: Vessel Replacement or Fiber Element Types Only, Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 50 μm, Element Seal Material: Vessel Replacement or Fiber Element Types Only, Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 03 (3/8 Rc), Element Type: T [Fiber (Honeycomb), Polypropylene Material], Nominal Filtration Accuracy: 100 μm, Element Seal Material: Vessel Replacement or Fiber Element Types Only, Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 2 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 70 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)