AQ340F-06 04 06 06 4.3-3 4.0-2 Precautions Be sure to read before handling.
141.1 99.2 99.2 19 42.9 (Lead wire length) 19 42.9 Polarity indication 13.6 13.6 A B A B B A A COM B + A B A B A B A Manual override (Push and turn for locking type) 42 31.4 Manual override (Press and turn for the locking type) 42 31.4 84.9 B: Green A: Orange 2-4.2 84.9 B: Green A: Orange 2-4.2 2-One-touch fittings (Mounting holes for manifold) (A, B port) (A, B port) 2-One-touch fittings
Universal type (throttle valve) 10-AS2301F-01-06-X214 10-AS1301F-M5-06-X214 10-AS2301F-01-06-X214 1.
-03 AMD150-03 1.5 0.2 HAA7-06 HAW2-04 AT6C-04 AFF2B-03 IDF2D-1 AM150-03 AMD150-03 2.2 0.3 HAA7-06 HAW7-06 AT6C-04 AFF2B-03 IDF3DAM150-03 AMD250-03 3.7 0.5 HAA7-06 HAW7-06 AT6C-04 AFF4B-03 IDF4DAM250-03 AMD250-03 5.5 0.7 HAA7-06 HAW7-06 AT6C-04 AFF4B-04 IDF6DAM250-04 AMD350-04 7.5 1.0 HAA15-10 HAW22-14 AT11C-06 AFF8B-04 IDF8DAM350-04 AMD350-04 11 1.5 HAA15-10 HAW22-14 AT11C-06 AFF8B-06 IDF11CAM350
, 07, 08, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 400 200 06, 07 TMH 02 01, 23 300 50 03, 04 ASD 200 100 01, 23 AS 100 AS-FE 0 0 0 5 0 10 5 0 10 5 0 10 KE Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
Twist selector (3 position) VM131-01-35 (R, B, G, Y) A VM151-01-35 (R, B, G, Y) A Panel mounting hole ON 45 T.T.
VH421-02 to 06 VH431-02 to 06 3 (Exhaust center) Rc 3/4: 58 2 position 3 position 3 4 2 1 Flow direction 4(B) 90 45 45 Flow direction 2 (A) Flow direction 4(B) Flow direction 2 (A) VH422-02 to 06 VH432-02 to 06 2 (Position) N Rc 3/4: 185 1 2 VH6 VH600-06/10 9.7 3 (Exhaust center) 3/4, 1 Rc 1: 194 3 4 5-8-7 2 Series VH How to Order VH 2 0 1 02 1(P) port location Hand valve R L 1(P) port 180
B All Ports: One-touch Fitting Model D1 D2 D3 d1 d2 d3 M1 M2 M3 L1 L21 L3 L4 A B C E F G1 J1 K1 N1 P1 Q1 ZH05DA-06-06-06 10.4 10.4 10.4 6 6 6 13.3 13.3 13.3 51.8 34.9 19.4 18.4 11 14 6 3.2 5.5 20 17 4.2 3.2 28 9.6 ZH07DA-06-06-06 55 ZH10DA-06-06-08 13.2 8 14.2 61.7 ZH13DA-08-10-10 13.2 15.9 15.9 8 10 10 14.2 15.6 15.6 71.8 43.9 22.4 24.4 17 20 9 4.3 7.8 27 22 4.2 35 12 ZH15DA-08-10-10 83.6
A B 2-P C L L C A B A B LVA10 2-F B B K LVA60 LVA20 With flow rate adjustment With indicator (Max.
, 07, 08, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 200 400 06, 07 TMH 02 01, 23 300 50 03, 04 ASD 100 200 01, 23 AS 100 AS-FE 0 0 0 5 0 10 5 0 10 5 0 10 KE Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
L E T U B E OD 6 A P P L I C A B L E T U B E OD 6 Courtesy of Steven Engineering, Inc. !
Parts (b) Lever Description Note C4: A, B port One-touch fitting for 4 C6: A, B port One-touch fitting for 6 No.
Set pressure range [MPa] 0.1 to 1.7 Ambient and fluid temperature [C] 5 to 60 (with no freezing) Applicable Model Applicable Model Model AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Model AR20-B AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Port size 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 r BG AR B B X430 30 03 BG q 30 AR
VH422-02 to 06 VH432-02 to 06 N Flow direction 2(A) Flow direction 4(B) Flow direction 2(A) Flow direction 4(B) 90 45 45 Rc3/4: 185(10.2) 1 2 9.7 VH6 VH600-06, 10 3 (Closed center) 3/4, 1 Rc1: 194(10.5) 3 4 3.6-6 Series VH How to Order VH 2 0 1 02 1(P) port location Hand valve R Standard (Opposite to handle side) Handle side Body size (Base size) Port size (nominal size) 2 3 4 6 1/4 base
3 position pressure center Note) (A) 4 (B) 2 5 B C A 5 (R1) 1 (P) 3 (R2) A C B Note) Except VQZ1000 and metal seal type.
SI unit output No. 0 1 2 3 4 5 6 7 8 9 SI unit output No. 0 1 2 3 4 5 6 7 A B A B B A Void A Void A A B A B B A A A SY Double Double Double Double Double SI unit SI unit Single Single Single Single Single SYJ Stations 1 2 3 4 5 Stations 1 2 3 4 5 Single/Double mixed wiring (Option) Double wiring (Standard) SX SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link
10 1/4 01 02 03 04 06 10 1/8 3/8 1/4 1/2 3/8 3/4 1/2 1 3/4 Option Note 1) 1 Symbol Nil B G Note 2) Applicable model AR25 to 60 AR25 to 60 AR25 to 40 Description With bracket With round pressure gauge (with limit indicator) With set nut (for panel mount) Option Note 1) Symbol Nil B G Note 2) Applicable model AR20 to 60 AR20 to 60 AR20 to 40 Description With bracket With round pressure
ASD Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS AS-FE 2 F A 1 AS 1 M5 06 0 E Body size 1 KE AS-FG F A 1 AS 2 01 06 2 0 S Body size 2/3/4 AS-FP AS-FM Body size Made to Order Refer to page 562 for details.
B B B B (4.4) 32 15.3 7.5 17 16 A A A A A 1 (Station n) (Station 1) L1 L2 (Pitch) P = 10.5 4.5 (Light/surge voltage suppressor) 15.5 15.5 (Station n) (Station 1) + + (Light/surge voltage suppressor) A A 20 48.5 [55.5] 15 5 B B + + 16 1.5 One-touch fitting (A, B port) Applicable tubing O.D.: 4, 5/32" (Pitch) P = 10.5 33.1 A A 20 15 B B 1 (Pitch) P = 10.5 5 M5 x 0.8 (A, B port) 16.5 L plug