Type: Line Filter, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 1 1/4B, Nominal filtration(μm): 40, Differential pressure display: Differential pressure display switch, Relief valve: N/A, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 3.5, Element: Micro-mesh, Flow Direction: IN left, Made-to-order
Type: -, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 3/4B, Nominal filtration(μm): 40, Differential pressure display: Differential pressure display switch, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 3.5, Element: Micro-mesh, Flow Direction: IN left,
Type: -, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 1B, Nominal filtration(μm): 40, Differential pressure display: Differential pressure display switch, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 7, Element: Micro-mesh, Flow Direction: IN left, Made-to-order
Type: -, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 1 1/4B, Nominal filtration(μm): 40, Differential pressure display: Differential pressure indicator, Relief valve: N/A, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 7, Element: Micro-mesh, Flow Direction: IN left, Made-to-order specifications
Type: -, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 1 1/4B, Nominal filtration(μm): 40, Differential pressure display: Differential pressure display switch, Relief valve: N/A, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 7, Element: Micro-mesh, Flow Direction: IN left, Made-to-order
Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 03 (3/8 Threaded), Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 10 [1 1/4 Threaded, 32 (1 1/4) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 1 (None), Fluid: 2 (Phosphoric Ester), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 1 (None), Fluid: 2 (Phosphoric Ester), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 4 (Differential Press. Indicator, Construction 42 Only), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 10 [1 1/4 Threaded, 32 (1 1/4) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 5 (Differential Press. Indication Switch, Construction 42 Only), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 10 [1 1/4 Threaded, 32 (1 1/4) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 10 [1 1/4 Threaded, 32 (1 1/4) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.