The cushion effect (smooth start-up, soft stop) is not available an intermediate stop or return from an intermediate stop using an external stopper, etc. When using an intermediate stop with the above information taken into account, implement measures to prevent particulate generation and set the operating pressure to no more than 0.3 MPa.
2.5 to 6 6 to 20 20 to 40 40 to 63 63 to 100 AS13l1F AS13l1F AS23l1F AS33l1F AS43l1F / 1 8, / 1 4 / 1 4, / 3 8 / 1 2 Elbow (Metal Body) M5 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 AS12l1 AS22l1 AS22l1 AS32l1 AS42l1 / 1 8 4.1-7 / 1 4 / 3 8 / 1 2 In-line 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 AS1001F AS2001F AS2051F AS3001F AS4001F 4.1-9 Dual Speed Controller 6 to 20 20 to 32 20
Variations Dimensions mm Weight g Tip color Applicable tubing Model D1 D2 L TKS-06 16 Orange TRB0604, TRBU0604 58 45 D2 D1 TKS-08 18 Yellow TRB0806, TRBU0805 35 TKS-10 Blue 20 TRB1075, TRBU1065 62 50 TKS-12 Green 22 TRB1209, TRBU1208 Inner tubing material/TRB: Nylon, TRBU: Polyurethane L 9.7 (3/8")
www.stevenengineering.com I 7.24 INSTRUMENTATION ELECTRO-PNEUMATIC REGULATOR D I M E N S I O N S S E R I E S VY140 0 102 03 04 D I M E N S I O N S S E R I E S VY150 0 102 03 04 D I M E N S I O N S S E R I E S VY170 0 110 12 D I M E N S I O N S S E R I E S VY190 0 114 20 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 !
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.
DI Sensor for HRL100/200/300-A*-20/40, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Thermistor Sensor HRL100/200/300-A-20/40, HRS090 AND LARGER CAPACITIES, O88, 10 lb
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Universal mounting Model Model Size (Nominal x Height) Piece Metric size Inch size TMH-23J TMH-04J TMH-06J TMH-06 TMH-01J TMH-03J TMH-05 TMH-07 TMH-09 TMH-11 TMH-13 M3 x 15 M3 x 20 1 M4 x 25 TMH-08 TMH-10 TMH-12 The holder can be used to secure an individual part.
Universal mounting Model Model Size (Nominal x Height) Piece Metric size Inch size TMH-23J TMH-04J TMH-06J TMH-06 TMH-01J TMH-03J TMH-05 TMH-07 TMH-09 TMH-11 TMH-13 M3 x 15 M3 x 20 1 M4 x 25 TMH-08 TMH-10 TMH-12 The holder can be used to secure an individual part.
When system performance declines due to filter element clogging, worn vacuum pads, piping leakage, etc., the switch can detect and indicate an oncoming problem before failure occurs.
In-line type AS1001F AS2001F AS2051F AS3001F AS4001F 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 Dual speed controller ASD230F ASD330F ASD430F ASD530F ASD530F ASD630F 6 to 20 20 to 32 20 to 40 20 to 40 40 to 63 63 to 100 M5 1/8 1/4 1/4 3/8 1/2 Applicable cylinder bore size (mm) Piping side port size Cylinder side port size Model AS1200 AS2200 AS3200 AS4200 M5 1 2 1/8 1/4 3/8 1/2 3/4 1 1
-02 KPGT06-M5 KPGT06-01 KPGT06-02 KPGT08-01 KPGT08-02 KPGT10-02 KPGT10-03 KPGT12-03 KPGT12-04 M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 8 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 6 13 19 7 14 20 14 22 29 39 41 38 17 21 25 18.5 23.5 27.5 26 30 33 34.5 37 39.5 4 4 4 D1 18 10.4 20.7 10 D1 8 A L2 6 10 10 19.5 12.8 22.8 D2 H Connection threads 10 (R) 8 26 18 15.2 21.5 26.3 12
D1 A2 T T Inch sizes L4 L5 A1 A2 M1 Max.
Weight (g) d L4 Model L3 T D1 H D2 D3 L1 L2 Max. Min.