Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Earth Leakage Breaker
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: w/Earth Leakage Breaker
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: With earth leakage circuit breaker
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 200 (20.5 kW), Thread: F (G, w/Rc-G Conversion Fitting), Option: B (w/Earth Leakage Breaker)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: B (w/Earth Leakage Breaker)
Cooling Capacity: 040 (Cooling Capacity: 3800W/4200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)
8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
are used 200 200 When 20 units are used 77% reduction Current model IR3000 Series 91% reduction 38000 yen reduction 150 150 117000 yen reduction Current model IR1000 Series IR2000 Series 100 100 IR1000-A Series IR2000-A Series IR3000-A Series 50 50 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Units used Units used Released into atmosphere IR Special bleeding structure No fixed throttle in the new
Description Qty 1 Rod cover 1 2 Head cover 1 3 Cylinder tube 1 4 Piston rod 1 5 Piston 1 6 Cushion ring 1 7 Cushion ring B 1 8 Bushing 1 9 Cushion valve 2 10 Tie-rod 4 11 Retaining ring 2 12 Spring washer 8 13 Tie-rod nut 8 14 Wear ring 1 15 Cushion seal 2 16 Rod seal 1 17 Piston seal 1 18 Cushion valve seal 2 19 Cylinder tube gasket 2 20 Piston gasket 1 21 Rod end nut 1 22 Magnet (1) 25
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Table 4 20 25 32 40 Rod seal CM20Z-PS CM25Z-PS CM32Z-PS CM40Z-PS The rod seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year.
Bracket (Option) AV R 1/8, 1/4 Dedicated mounting screw AU 22 14 (Hex. width across flats) (M4 x 0.7) M5 x 0.8 38 AF 2 26 2-4.5 600 8 AR (Lead wire length) 19 3 25 IR 5 9 8 5 VEX 36 1 3 22 22 AMR 3.2 ITV IC M5 type PT type 40 VBA VE SMC DIGITAL PRESSURE SENSOR ALM. SET 20 VY1 + G P.SET PPA AL 14-11-19
SET 20 VY1 + G P.SET PPA AL 14-11-19
SUP (SUP air) IN (SIG air) qInput chamber uDiaphragm A iDiaphragm B oSpool wFeedback spring EX OUT2 EX OUT1 eInput diaphragm yNozzle rConnecting rod tCylinder rod 152 Cylinder Positioner IP200 Series Dimensions 20 20 25 SIG OUT1 OUT2 20 25 2 x 6.6 OUT1 OUT2 IN side Rc1/4 38 60 50 SUP 31 35 135 + Stroke IP IP IW 97 1301 40 SUP AW 37 Rc1/4 M8 x 1.25 depth 15 IL1 66 62 + Stroke 80 IL2 Precautions