In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc.
If an accurate stopping position is required at the stroke end or midstroke, use an external stopper to secure accurate positioning.
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Fluid Fill Port, Manual Fill
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Fluid Fill Port, Manual
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: K (w/Fluid Fill Port, Manual Fill)
/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.
Note 1) This cylinder cannot perform an intermediate stop using an air pressure circuit in vertical operation. In this case, an intermediate stop can be performed only by using an external stopper, etc. Note 2) Made-to-order products should be considered, too, depending on an operating environment, etc.
J 70C Nylon tarpaulin K 110C* Neoprene cloth * Maximum ambient temperature for the rod boot only. Mounting Bracket Part No.
When disassembling a cylinder with a bore of 20 to 40, use a vise or the like to hold the wrench flats portion of the tube cover or the rod cover on one side, while placing a wrench or an adjustable wrench on the other side to loosen and remove the cover. To replace, tighten it an additional 28 from the installed position.
Description Body class Symbol Bracket assembly LQ-GBL J K 1, 2 J type K type 1, 2, 3, 4, 5, 6 L M L type M type (for short piping) Table 1 Tubing size symbols Replacement parts Tubing O.D. Metric sizes Tubing outside diameter Part No.
An approximate plate-end deflection X without a load is shown in the graph below.
Refer to page 120 for an order example.
If there is no buffer mechanism, an excessive impact force is generated. As a result, the tensile compression force of the floating joint may exceed its maximum level.
The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount switches in locations where there is no vibration greater than 98 m/s2, or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.
AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.
Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.
Never use in an atmosphere of explosive gases. 6. Do not use in an environment where there is excessive impact shock. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.