Note 6) Product other than the option R is not equipped with an earth leakage breaker. Please purchase an appropriate earth leakage breaker separately.
3 m 5 m None Solid state switches marked with are produced upon receipt of order.
Lead wire length symbols: 0.5 m Nil (Example) Y69A 3 m L (Example) Y69AL 5 m Z (Example) Y69AZ Since there are applicable auto switches other than the listed above, refer to page 9-11-29.
Bore size 20, 25/MLGPM20/25 (Slide bearing) Operating Range as Stopper for MLGPM20/25 100 25 l = 50 mm l = 50 mm Weight of transferred object: m (kg) m m 20 5 10 10 20 30 40 50 Transfer speed: (m/min) Bore size 32 to 100/MLGPM32 to 100 (Slide bearing) Operating Range as Stopper for MLGPM32 to 100 1000 Weight of transferred object: m (kg) l = 50 mm l = 50 mm 100 m m 80 63 50 40 32 100
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
plug connector (M) M8 connector (WO) Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.7 [60.9] 48.9 [51.1] 57.8 50.4 43.9 Refer to page 646 for dimensions with connector cable.
JS20, 32, 40, 63 Center of sphere M M U U D J F B E G P A R H (mm) Max. thread depth P Center of sphere R Allowable eccentricity U Max. operating tension and compression force (N) Weight (kg) M A B C D E F G H J Model JS10-4-070 JS16-5-080 8.5 0.5 17 0.01 14.4 M4 x 0.7 9.5 12 4 7 4.7 80 4 1.5 26 12 0.5 23 19 0.02 M5 x 0.8 13.5 16 6 10 5.8 210 5 2 34.5 JS20-8-125 JS32-10-125 15.5 0.5 29.9
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state switches marked with are produced upon receipt of order. Since there are other applicable auto switches than listed above, refer to the Best Pneumatics No. 2 for details.
52 46 55 63 69 S 33 36 40 46 50 52 Z 46 52 56 65 73 79 6 10 16 20 25 32 7 9 12 16 20 24 6 depth 4.8 6 depth 5 7.6 depth 6.5 9.3 depth 8 9.3 depth 9 11 depth 11.5 5 7 Free Mount Cylinder Double Acting, Single Rod Series CU Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-A9 D-M9 D-F9W 22 (24.5) ( ): Denotes the values of D-A93.
(The switch will stay ON all the time.) 1) For an auto switch without a connect protection circuit, use a contact protection box when the wire length is 5 m or longer. 2) Even if an auto switch has a built-in contact protection circuit, when the wiring is more than 30 m long, it is not able to adequately absorb the rush current and its life may be reduced.
Symbol Specifications -X12 Lubricant: Vaseline -X21 Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X214 Restrictor (Without check valve) 10Clean Series 565 A AS Series Needle Valve/Flow Rate Characteristics AS2201F-G02-m, AS2211F-G02-m AS2301F-G02-m, AS2311F-G02-m AS2201F-02-mPA, AS2211F-02-mPA AS2201F-G01-m, AS2211F-G01-m AS2301F-G01-m, AS2311F-G01-m AS2201F-01-mPA
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J Kit J Kit F Kit F L S The valve is equipped with an indicator light/surge voltage suppressor, and the voltage is 24 VDC. kit (Serial transmission unit) kit (Lead wire cable) The dust-protected type SI unit is applicable
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude For the product operation at an altitude of 1800 meters, the cooling capacity at an altitude of 1800 meters = Cooling capacity 8.4 x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
The drawing shows with an auto switch. Eliminate the unnecessary parts.
Air Piping Compressor Air Delivery Caution Caution HAA HAW IDFA55E, 75E Compressed air inlet Compressed air outlet Use an air compressor with an air delivery of 100 L/min or larger with the IDFA3E to 75E series.
Mounting orientation and static moment Mounting orientation Static load Horizontal mounting Ceiling mounting Wall mounting Vertical mounting Bore size (mm) A [mm] 6 10 15 20 25 32 40 m m x g x x m x g x y 19 21 25 27 33 40 49 m x g x x m x g x y m x g x (z + A) m x g x x m x g x (z + A) m x g x y M1 M2 M3 Static moment A: Distance between the center of the guide shaft and the upper surface
L dimension 1.5 m 3 m 5 m Part no. L dimension 1.5 m 3 m 5 m AXT100-MC26-015 AXT100-DS25-015 AXT100-MC26-030 AXT100-DS25-030 AXT100-MC26-050 AXT100-DS25-050 When a commercially available connector is required, use a 25 pin female connector conforming to MIL-C-24308. L L (60) 44 Approx. 10 8 16 14 25 1 13 47.04 55 Multi-core vinyl cable 0.3 mm 2 x 25C 2 x M2.6 x 0.45 Terminal no.