Bore sizes 10, 20, 30, 40, 50 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75, 100 Standard strokes (mm) 6 10, 15 20, 25, 32 Applicable auto switches: Refer to pages 40 through 49 for detailed auto switch specifications.
4-MM thread depth J L 0 0.1 H B 2-P (Piping port) G E G NN ( I ) D X NA R Mounting nut N W K N S + Stroke F F ZZ + Stroke H B E G Mounting nut NN NA F N CY3B15 (mm) Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 B 35 36 46 60 70 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 D 16.6 21.6 26.4 33.6 41.6 ZZ 103 132 137 156 182 E 3 2 2 2 3 N 11 18 18.5 20 26
) Stroke range Width across flats Effective thread length 32 40 50 63 80 100 B C A E F G H MA MB J MM N V W M6 x 1.0 M6 x 1.0 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 4 4 5 5 5 5 12.2 14.2 19 19 23 27 47 51 58 58 72 72 M10 x 1.25 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 27 27 31.5 31.5 38 38 135 139 156 156 190 190 30 35 40 45 45 55 22 30 35 35 40 40 19.5 27 32 32 37 37 32.5 38 46.5
40 20.5 166 8 97.5 55 20 25 6.8 28 142.5 3.2 40 47 24.5 175 8 102.5 55 20 CEP1 CE1 Rod side flange style: MQMLF 6 CE2 20 ML2B 2.3 C J G5-S 33 42 27.5 2-5.5 66 + Stroke 93.5 + Stroke CV MVGQ 10, 16, 20, 25 CC RB FY J FT FX FZ H 2-FC S + Stroke ZZ + Stroke D-X 20Bore size (mm) FC FT FX FY FZ H ZZ S Data 10 5.5 2.3 33 20 42 28 101 65 16 5.5 2.3 42 24 54 30 114 74 20 7 4 60 34 75 40.5 151 97.5
28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.
/Angle type C D L2 (KF flange) Fn Fc C (Fc) L1 (CF flange) J H B G A A (mm) Model A 110 120 171 B 38 48 66 C 1 1 2 D 30 40 55 Fn 34 70 Fc 17 26 41 G 40 39 63 H J P.C.D L1 6 x 4.4 6 x 6.6 L2 XMC-16 XMC-25 XMC-40 40 50 65 26 28 36 P.C.D 27 P.C.D 58.7 XMC-50 to 80/Angle type C L2 D Fd Fc L1 (KF flange) Fn C (K flange) (CF flange) H J K B G A A (mm) Model A 183 209 250 B 80 100 117 C 31 39
Refer to page 120 for an order example.
D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV ( ) MY1CW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 63 50 40 32 25 Mounting position 40 32 25 Mounting position 25 Mounting position 32 40 50 63 A 323.5 278.5 157.5 127.5 97.5 157.5 127.5 97.5 97.5 127.5 157.5 278.5 323.5 A A B 136.5 121.5
0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRR010-W-20 [50 Hz] [60 Hz] 400 400 35C Heating capacity [W] Heating capacity [W] 35C 300 300 25C 25C 200 200 5C 5C 100 100 Facility water temperature Facility water temperature Facility water temperature Facility water temperature 0 0 10 15 25 20 30 40 35 10 15 25 20 30 40 35
Kit J Kit F Kit F L S The valve is equipped with an indicator light/surge voltage suppressor, and the voltage is 24 VDC. kit (Serial transmission unit) kit (Lead wire cable) The dust-protected type SI unit is applicable, too.
14 30 27.6 21 3 56.5 42 30 158 146 CG-E020SUS 2032 10 141 7 11 4 22 40 38.4 29 4 70.5 56 40 170 152 CG-E032SUS 40 10 159 7 11 4 22 40 38.4 29 4 70.5 56 40 188 170 CG-E032SUS Data 50 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 63 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 80 22 234 14 23 6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 100 22 235 14 23
14 30 27.6 21 3 56.5 42 30 158 146 CG-E020SUS 2032 10 141 7 11 4 22 40 38.4 29 4 70.5 56 40 170 152 CG-E032SUS 40 10 159 7 11 4 22 40 38.4 29 4 70.5 56 40 188 170 CG-E032SUS Data 50 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 63 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 80 22 234 14 23 6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 100 22 235 14 23
-16 XMC-25 XMC-40 XMC-50 XMC-63 XMC-80 40 50 65 70 88 90 26 28 36 38 45 56 P.C.D 27 P.C.D 58.7 P.C.D 92.1 XYC/In-line type C D G Fd C (K flange) B J H 45 E A Fn (KF flange) (mm) Model A 85 115 129 158 189 B 48 66 79 100 117 C 1 2 2 3 3 D 23.5 38 53 61 80 E 40 55 75 87 114 Fn 95 110 Fd 26 41 52 70 83 G 64 84 95 118 142 H J XYC-25 XYC-40 XYC-50 XYC-63 XYC-80 100.2 130 178 209 268 28 36 38
MHL2-16DZ 40 45 60 28 68 98 128 26 98 MHL2-16D1Z 70 75 90 58 110 170 200 50 152 MHL2-16D2Z 90 95 110 78 130 210 240 70 192 J dimension is at fully closed.
An EXH block base ass'y is used in the blocking position when ordering an EXH spacer incorporated with a manifold No. However, do not order an EXH block base ass'y because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base ass'y because it is not attached to the spacer.
MVGQM, MVGQL Common Dimensions ML2B Applicable solenoid valve B C DA G GA H J K L MM ML NN Q R S T V W X YY YL Z Bore size (mm) Standard stroke (mm) TA TB U Over 10 st 10 st C J G5-S 12 6 29 50 13 18 58 39 22 56 2 5 36 40 14 7 12 29 5 48 20 30 16 M4 x 0.7 10 M4 x 0.7 M4 x 0.7 10, 20, 30, 40, 50, 75, 100 16 CV 8 33 54 64 15 22 43 25 62 2.5 5.5 38 42 16 8 13 33 7 52 23 30 18 M5 x 0.8 13 M5
3) Body size With bracket B AFM20 to 40 Port size C With bowl guard AFM20 Thread type Symbol 20 30 40 J Note 5) Float type auto drain (N.C.)
If an accurate stopping position is required at the stroke end or midstroke, use an external stopper to secure accurate positioning.
4-MM thread depth J L 0 0.1 H B 2-P (Piping port) G E G NN ( I ) D X NA R Mounting nut N W K N S + Stroke F F ZZ + Stroke H B E G Mounting nut NN NA F N CY3B15 (mm) Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 B 35 36 46 60 70 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 D 16.6 21.6 26.4 33.6 41.6 ZZ 103 132 137 156 182 E 3 2 2 2 3 N 11 18 18.5 20 26
(Lm/2) 190 40 10 40 10 10 35 10 190 35 Most sensitive position Operating range of single auto switch Lm Rotation range m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.