Flange size XMD Symbol Nil D C Type KF (NW) K (DN) CF Applicable flange size 25, 40, 50, 63, 80 63, 80 40 (070), 63 (114) XYD V V V V V XMD V V V V V Size 25 40 50 63 80 XYD Nil D KF (NW) K (DN) 25, 40, 50, 63, 80 63, 80 3.
MGP MGPA12-150 MGP MGPA12-100 MGPA -200 32 40 MGPA -150 32 40 MGPA -100 32 40 MGPA -200 32 32 40 40 0.2 0.4 MGP MGPA12-75 MGPA12-75 MGPA -150 32 32 40 40 0.15 0.3 MGPA -100 32 32 40 40 0.1 0.2 MGPA12-50 MGPA12-50 MGPA -50 32 40 MGPA -50 32 32 40 40 0.05 0.1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area
5 K 14 10 8 6 KA 1 2 23 0<23> 0 0 40 32 25 20 30 22 22 18 10 0 0 0 27 27 32 38 20 20 30 32 2 2 14<12> 14<12> 58 58 218 218 80 40 37 32 50 25 40 3 20<17> 71 13 89 M10 x 1.5 depth 22 10 22 M22 x 1.5 80 3/8 10 122 10 20 264 100 40 37 41 60 30 50 3 20<17> 71 16 110 M12 x 1.75 depth 22 10 26 M26 x 1.5 100 1/2 10 122 10 20 264 50 35 32 63 35 32 11 11 58 72 10 10 23 20 M18 x 1.5 M18 x 1.5 55 69
Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 40 30 20 20 30 40 50 3. Select the bore size and type of magnet holding force (types H, L) from Lo and Fn based on data K A .
When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.
D Lever type models Caution RS (D) 32/40/50-L RS (D) 32/40/50-B RS (D) 32/40/50-C RS (D) 32/40/50-D RS (D) 32/40/50-E Mounting base 1. Do not allow a pallet to collide with the cylinder when the lever is upright.
40 HRS090 Standard type 0.5 5 to 35 Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option)
Never use in an atmosphere of explosive gases. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized.
In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc. Two or four sensor inputs can be accommodated by one input block, and the common can be matched to the sensor by an NPN/PNP switch.
LER MH LEH ML + Stroke MA MC MD Section XX LEY -X5 Section XX details 11LEFS XB 11LEJS XA H9 XA 25A[mm] Size Stroke range [mm] C D EH EV H J K L M O1 R S T U B V LEC 25 15 to 100 13 20 44 45.5 M8 x 1.25 24 17 14.5 34 M5 x 0.8 8 45 46.5 1.5 136.5 40 105 to 400 161.5 LEC S 32 20 to 100 13 25 51 56.5 M8 x 1.25 31 22 18.5 40 M6 x 1.0 10 60 61 1 156 60 105 to 500 186 LEC SS-T 63 50 to 200 21 40
10 8 6 8.5 8 13 17.5 21.5 25 25 25 152 40 60 40 40 10 9 6 8 13 17.5 10.5 24.5 32 32 32 154 40 60 40 40 10 9 6 8 13 17.5 11.5 27 40 40 40 188 44.5 77 53 53 11 10 8 11 16 21.5 15 32.5 6-4-34 35 Series CDM2W Air Cylinder: Standard Type Double Acting, Double Rod Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height Reed switch Solid state switch D-H7/H7W/H7NF
AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.
AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.
Values) Horizontal load Note: 1N = 0.2248 lbf 1in = 25.4mm Displacement MGPA32, 40 MGPA12 0.4 0.8 MGPA -400 32 40 32 40 MGPA12-250 MGPA12-250 MGPA -400 0.35 0.7 Plate displacement mm Plate displacement mm 0.3 0.6 MGPA -300 32 40 MGPA -300 32 40 0.25 0.5 MGPA12-150 MGPA12-150 MGPA12-100 MGPA -200 32 40 MGPA12-100 MGPA -200 32 40 0.2 0.4 MGPA12-75 MGPA12-75 MGPA -150 32 40 MGPA -100 32 40
AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR50(K) AR40(K)-06 AR60(K) No.
AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR50(K) AR40(K)-06 AR60(K) No.
Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.
(Lm/2) 190 40 10 40 10 10 35 10 190 35 Most sensitive position Operating range of single auto switch Lm Rotation range m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.
with an are the same as standard.
TEMPERATURE -40 to 200 F (-40 to 93 C) RECOMMENDED FILTRATION 5 Micron PANEL MOUNT Thru hole = 5/16" (0.132) diameter Max. Panel Thickness = 0.15" NV-30FITTING SIZE ADJUSTMENT STYLE 2 = 1/16" BARB 4 = 1/8" BARB S = SCREWDRIVER K = KNOB NV-30 SERIES NV-30 FLOW DATA PRESSURE ACROSS NEEDLE VALVE Back to Top .