The IZF21/31 fans offer market-leading performance, functionality, size and accessories. Treat an area up to 2' x 8', neutralizing static as rapidly as 0.5s while achieving a ±5V balance. 8 emitters provide high ion output, and reverse polarity each time power is supplied, increasing durability.
The IZF21/31 fans offer market-leading performance, functionality, size and accessories. Treat an area up to 2' x 8', neutralizing static as rapidly as 0.5s while achieving a ±5V balance. 8 emitters provide high ion output, and reverse polarity each time power is supplied, increasing durability.
And for the IZF21/31, the excess current on output circuit, incorrect high voltage, power supply failure, fan motor failure, CPU failure, maintenance warning, emitter cartridge mounting failure, and automatic cleaning failure alarms cannot be checked.
However, for IZF21/31 series ionizers, the power cable connector cannot be ordered individually.
Instead, replace the power cable as a whole with the part number “IZS41-CP□.”
IZF21/31 series ionizers are marked with “ADJUST” on the front of the product.
For details on adjusting the offset voltage, refer to the operation manual.
The IZF series operation manual can be found here.
Ionizer with flow rate adjustment function that enables extensive, rapid static neutralization.Features · Covers an extensive static neutralization area with adjustable louver.· Stable static neutralization performance and easier maintenance.· 7 types of alarm functions as standard.· LED indicator can be checked from 2 directions.· Filter prevents ingress of lint and foreign matter, etc.
When the NDL LED is blinking red, this indicates an emitter cartridge mounting failure. Check whether the emitter cartridge is installed properly.