LJ1H303NDStroke -F-X70 LJ1H303SEStroke -F-X70 LJ1H303PAStroke K-F-X70 LJ1H303NAStroke K-F-X70 Combinations other than the above cannot be manufactured.
1/8 81 M24 x 1.5 13 28 19 15 143 32 Up to 800 21 M14 x 1.5 24 22 38 16 19 12 8 53 8 9 40 31 f8 7.5 1/8 87 M30 x 1.5 13 36 19 15 159 40 Up to 800 21 M33 x 2 M16 x 1.5 24 24 41 18 21 14 11 54 10 11 48 34 f8 7.5 1/4 108 19 44 24 21 183 Axial foot type: CHML Width across flats B2 H N GA F N GB F Rc P Rc P 2 x NN Width across flats B1 Effective thread H2 H1 D I 4 x LD LH MM A K NC Width across
Parts list No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No.
Parts list No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No.
Double wiring specification specification 12 13 12 13 12 stations 12 stations 13 stations 13 stations Specified wiring Note 2) Specified wiring (up to 25 solenoids possible) ... ... ... ...
Specifications Positive COM AXT661-14A-F Single (2 wire) VQ4 Negative COM AXT661-14AN-F Positive COM AXT661-13A-F VQZ Double (latching) (3 wire) Negative COM AXT661-13AN-F VQD Note) Lead wire length: 300mm Note) The parts numbers above are applicable to VQ0/1000 (2 to 16 stations) and 13 14 VQ2000 (2 to 10 stations). VQ2000 (11 to 16 stations) uses AXT661 A (N)F425. VZS VFS 3.
F_Source/Destination_Address (F-Address) F-Source F-destination F-Address F-Address F_WD_Time F_WD_Time PROFIsafe ms F_SIL SIL F_iPar_CRC i-Prameters F_Par_CRC F-Parameters CRCF-Parameters F-CPU Failsafe controller, safe controller F_Destination_Address F-Parameter (F-Parameter) F-I/O device Failsafe I/O I/O 100 No.EX##-OMY0006CN F-Slave Failsafe slave F_Source_Address F-Parameter
CB CD DD E F FL LR M MR R NCA1-P150 3/4 1/2 13/32 2 1/2 3/8 1 1/8 3/4 1/2 9/16 1.63 NCA1-P325 1 1/4 3/4 17/32 3 1/2 5/8 1 7/8 1 1/4 3/4 7/8 2.56 CD dia. DD dia. Clevis Bracket AA 2.3 3.6 1 5/8 2 9/16 0.785 1.265 1/2 3/4 1/2 5/8 3/8 -24 1/2 -20 2 1/2 3 1/2 3/8 5/8 1 1/8 1 7/8 1/2 1 1/16 1/2 3/4 9/16 1 1/16 Part no. BA CB CD CW DD E F FL LR M MR NCA1-CB150 NCA1-CB325 DD dia.
CB CD DD E F FL LR M MR R NCA1-P150 3/4 1/2 13/32 2 1/2 3/8 1 1/8 3/4 1/2 9/16 1.63 NCA1-P325 1 1/4 3/4 17/32 3 1/2 5/8 1 7/8 1 1/4 3/4 7/8 2.56 CD dia. DD dia. Clevis Bracket AA 2.3 3.6 1 5/8 2 9/16 0.785 1.265 1/2 3/4 1/2 5/8 3/8 -24 1/2 -20 2 1/2 3 1/2 3/8 5/8 1 1/8 1 7/8 1/2 1 1/16 1/2 3/4 9/16 1 1/16 Part no. BA CB CD CW DD E F FL LR M MR NCA1-CB150 NCA1-CB325 DD dia. CD dia.
VQ1000 (VV5Q13)-Plug-in Unit, Flip Type (F, P, J, L, S kit) . VQ0 (VV5Q04)-Plug Lead Unit, Flip Type (F, P, T, S kit) . VQ1000 (VV5Q14)-Plug Lead Unit, Flip Type (F, P, T, S kit) . VQ2000 (VV5Q24)-Plug Lead Unit, Flip Type (F, P, T, S kit) .
Seal kits consist of items 12, 13, 14 and 16 contained in one kit, and can be ordered using the order number for each respective tube bore size. 13 Series MB1W Standard Type MM MM G VW 2-Rc(PT)P G Cushion valve Port Basic type/(B) E D D E e MB Effective thread Effective thread 13 f 16 h 9 2 x 4-J N F l H + Stroke A K ZZ + 2 strokes S + Stroke H A K F N C B With rod boot MM 2-Rc(PT)P G G
9.5.1 HRR012-A/W-10-,HRR018-A/W-10-. 9-13 9.5.2 HRR012-A/W-20,HRR018-A/W-20 . 9-13 9.5.3 HRR024-A/W-20,HRR030-A/W-20 . 9-13 9.6 Pump capacity. 9-14 9.6.1 HRR012/018/024/030-A/W. 9-14 9.6.2 HRR012/018-A/W-10-T/MT . 9-14 9.6.3 HRR012/018/024/030-A/W-20-T . 9-15 9.6.4 HRR012/018/024/030-A/W-20-MT . 9-15 9.6.5 HRR012/018/024/030-A/W-20-T1 . 9-16 9.7 Required facility water flow (for water-cooled
+ Stroke ZZ + Stroke NA I 3 (mm) Effective thread length (mm) IA (tolerance) Bore size (mm) Stroke range (mm) A B1 B2 D F GA GB H H1 H2 I K MM P S NN N NA NB NC ZZ -0.020 -0.053 -0.020 -0.053 -0.025 -0.064 -0.025 -0.064 20 18 13 26 10 16 12 8 41 5 8 30 5 M8 x 1.25 1/8 81 M22 x 1.5 13 26 19 15 138 23 f8 15.5 to 800 25 22 17 32 12 16 12 8 46 6 8 32 5.5 M10 x 1.25 1/8 81 M24 x 1.5 13 28 19
l h h + L8 + H + 2 x Stroke With rod boot at both ends d d e e L8 + Stroke h f l l + Stroke f 2 x h + L8 + 2 x Stroke h + Stroke A B d11 D EE PL RT L12 KK SW G BG L8 VD WA WB WH ZY Bore size (mm) Stroke range (mm) L2 L9 32 40 50 63 80 100 125 190 26 7 4 4 94 16 32 10 M10 x 1.25 6 M6 x 1 13 G 1/8 4 12 15 30 Up to 1000 22 213 30 9 5 4 105 16 37.5 13 M12 x 1.25 6.5 M6 x 1 14 G 1/4 4 16 17 35
If disassembly is required, please contact SMC.) 368 CG3 Series Air Cylinder Short Type Standard: Double Acting, Single Rod Dimensions Basic: CG3BN Bore size Stroke With rubber bumper 2 x P GA GB F Width across flats KA Female Rod End R0.5 (mm) CJ1 H1 Bore size (mm) Standard stroke A1 MM D H MM ZZ CJP 20 25 32 40 50 63 80 100 0 E 0.05 13 14 14 15 16 16 19 22 Up to 200 8 8 12 13 18 18 21 25
Dimensions [mm] Size Stroke range [mm] A B C D EH EV H J K L M O1 R S S2 T T2 U CV V X2 Y Without lock With lock 25 15 to 100 136.2 121.7 13 20 44 45.5 M8 x 1.25 24 17 14.5 34 M5 x 0.8 8 46 58.1 115 113.6 1 66.3 57.8 144 184 32.2 101 to 400 161.2 146.7 32 20 to 100 153.6 135.1 13 25 51 56.5 M8 x 1.25 31 22 18.5 40 M6 x 1 10 60 70.8 142 140.3 2 83.5 69.8 144 189 39.1 101 to 500 183.6 165.1
I H1 MM D NB ND NE C Effective thread E E NF 10 N JD N JC 10 A K F NA S + Stroke F H WH B ZZ + Stroke (mm) A B C D E F GA GB H H1 H2 I Bore size (mm) Stroke range (mm) Effective thread length 26 8 5 44 47.5 53.5 16 14.5 10 18 40.5 32 15.5 200 to 700 20 31 8 6 48 49.5 56.5 16 18 12 22 45.5 36 19.5 200 to 700 25 38 9 6 51 51.5 55 19 18 12 22 51.5 44 19.5 200 to 1000 32 47 11 8 54.5 51.5 56
Electrical entry F: Plug-in type Option Port size Nil 01 Without sub-plate Rc 1 8 50 01 F Z VZS2 1 2 Plug-in 5 G 50 VZS2 Non plug-in 2 01 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil rated voltage Symbol Thread type 1 2 3 2 position single 100 VAC, 50/
ExampleRod end nut for JS40 CV MVGQ CC RB J D-X 20Data 10-19-13 14 Series JS Dimensions JS10, 16 Center of sphere M M U D J U F B G H C E P Use the precision spanner for clock 4 mm in the case of mounting male thread of JS10.
ExampleRod end nut for JS40 CV MVGQ CC RB J D-X 20Data 10-19-13 14 Series JS Dimensions JS10, 16 Center of sphere M M U D J U F B G H C E P Use the precision spanner for clock 4 mm in the case of mounting male thread of JS10.