resistance [m/s2] Note 3)Actuation typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 4)Standby power consumption when operating [W] Note 5)Max. instantaneous power consumption [W] Note 6)Type Note 7)Holding force [N]Power consumption [W] Note 8)HorizontalVerticalLEFS16A100, 200, 300
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 7.49571 lb, Stroke Model1002003004005006007008009001000Manufacturable stroke range [mm]LEFS25??????????100 to 600
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 13.6907 lb
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, PNP, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 2.09438 lb, Stroke Model1002003004005006007008009001000Manufacturable stroke range [mm]LEFS40??????????200 to 1000
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.? Through the combination of parallel I/O inputs, 14 points of positioning are available.? The speed and acceleration of the positioning can be set by the switch for each operating direction.? A single signal sent to a dedicated terminal returns an actuator to
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 14.33004 lb
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length
Bearing Type: Ball Bushing Bearing, Stroke: 300mm, Motor Option: w/Motor Cover, Actuator Cable Type: R [Robotic Cable (Flexible Cable)], Actuator Cable Length, m: 1.5, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 1.5, Communication Plug Connector: None, Controller Mounting: DIN Rail Mounting, DIN Rail not Included, Made to Order: -
Size: 10, Motor Size: Compact Type, Lead Screw Type, mm: LEPS6: 4; LEPS10: 5, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: R [Robotic Cable (Flexible Cable)], Actuator Cable Length, m: 1.5, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 1.5, Communication Plug Connector: None, Controller Mounting: DIN Rail Mounting, DIN Rail not Included
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEPS6: 4; LEPS10: 5, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: R [Robotic Cable (Flexible Cable)], Actuator Cable Length, m: 1.5, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 1.5, Communication Plug Connector: None, Controller Mounting: DIN Rail Mounting, DIN Rail not Included
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEPS6: 8; LEPS10: 10, Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: R [Robotic Cable (Flexible Cable)], Actuator Cable Length, m: 1.5, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 1.5, Communication Plug Connector: None, Controller Mounting: DIN Rail Mounting, DIN Rail not Included
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEPS6: 4; LEPS10: 5, Stroke: 25mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: R [Robotic Cable (Flexible Cable)], Actuator Cable Length, m: 1.5, Controller Type: LECP6, Step Data Input Type, PNP, I/O Cable Length, m: 1.5, Communication Plug Connector: None, Controller Mounting: DIN Rail Mounting, DIN Rail not Included