Series CU comparison Allowable kinetic energy (J) : with air cushion Noise reduction of more than 11dB is possible (compared to Series CU20 with rubber bumper). : with rubber bumper 3 Interchangeable mounting Mounting dimensions (J, K, R, and E) are the same as the rubber bumper type Series CU. 2 1 0.70 0.44 0.11 0.28 0.29 0. 18 R 20 25 32 E Bore size (mm) Improved repeatability K J When
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com WA Z Bottom view Section XX Z WA L 4-MM depth ML Section XX HA: T-slot for hexagon bolt 4-NN through 4-OA through 4-OB counterbore depth OL X 0.02 X 0.02 DA VB VA R U T X H PW DB XA depth 6 H7 XA depth 6 H7 2-P (Rc, NPT, G) GA 2-P PB (Rc, NPT, G) J K
The weight will increase by 1kg when option J [Automatic fluid filling] is selected.
1 Escapements Series MIW/MIS 8, 12, 20, 25, 32 RE A B REC CX CY MQQ M RHC MK(2) RS Q G RS H A RZQ MI W S CEP1 CE1 CE2 ML2B C J G5-S CV MVGQ CC RB J Ideal for separating and feeding individual parts from vibratory feeders, magazines, and hoppers.
.: J (NPT thread: K inch) Purge air for dehumidification Purge air for dehumidification (Maintenance space 100mm or more) Option: P Port size L A B C D E Model F G J H K 97 224 8 119 [126] 5/16 114 249 10 147 [154] 3/8 83 187 53 165 62 113 212 54 190 82 IDG10, IDG10H IDG20, IDG20H Values inside [ ] are for NPT threads 1/4, 3/8 15 Membrane Air Dryer Series IDG Dimensions (mm) 1in = 25.4mm
MGPM, MGPL Common dimensions (mm) Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB H HA J K L MM ML NN OA OB OL P PA PB PW 42 29 11 7.5 8 8.5 9 M4 x 0.7 10 12 13 15 M4 x 0.7 4.3 4.3 5.6 5.6 M5 x 0.8 6 8 10 12 58 64 83 93 8 8 9.5 9.5 13 8 8 10 10 M4 M4 M5 M5 4.5 4.5 5.5 5.5 8 5 5 6 6 13 15 18 21 18 26 30 36 42 13 15 18 21 18 22 24 30 12 16 20 25 10, 20, 30, 40, 50, 75, 100 125, 150
G5-S 20 is socket set screw CV MVGQ CC 20, 32 only RB J Replacement Parts: Shock Absorber Replacement Parts: Seal Kit DKit no.
.: J (NPT thread: K inch) Purge air for dehumidification Purge air for dehumidification (Maintenance space 100 mm or more) Option: P Port size L A B C D E Model F G J H K 97 224 8 119 [126] 5/16 114 249 10 147 [154] 3/8 IDG10/10H IDG20/20H Values inside [ ] are for NPT threads. 83 187 53 165 62 113 212 54 190 82 1/4, 3/8 14-19-30 27 Series IDG Membrane Air Dryer Single Unit Type IDG30/50
0.4 J 0.65 J 1.2 J JIS Symbol Double acting, Single rod CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB Standard Stroke Maximum stroke (mm) Standard stroke (mm) Note) Bore size (mm) MB1 20 1000 CA2 25 1500 25, 50, 75, 100, 125, 150 200, 250, 300 32 CS1 2000
Symbol Material -XC14 Change of trunnion bracket mounting position J 70C Nylon tarpaulin -XC15 Change of tie-rod length Bore size (mm) Cylinder stroke (mm) 110C K Heat resistant tarpaulin -XC18 NPT finish piping port 180 1,569 Maximum ambient temperature for the rod boot itself.
Fluid supply 9 Overflow port (Option J) Tank drain port To wastewater collection pit 5 No.
J Nylon tarpaulin 70C K Heat resistant tarpaulin 110C* * Max. ambient temperature for rod boot itself. Water Resistant Air Cylinder Mounting Brackets/Part No.
Unit AC10A to 40A Dimensions AC10A, 20A A N F E P K C G G IN OUT Q B Pressure gauge (Option) K H OUT Pressure gauge port size Square embedded type pressure gauge (Option) J L Port size Lubricator M Drain Min. clearance for maintenance Filter regulator D A N F AC30A, 40A E P K C G G OUT IN Q B Pressure gauge (Option) K OUT Pressure gauge port size J L Square embedded type pressure gauge (
Q F Z Stroke 32 40 50 RSQB -DZ (Double acting) Bore size: 32, 40, 50 M E J 2 x P (Rc, NPT, G) T 0 0.1 D Q F Z Stroke M E J T 0 0.1 D Width across flats K A + 2 stroke B + Stroke V H + Stroke 2 x P (Rc, NPT, G) E M 4 x N through 8 x O counterbore Q F Z Stroke T 0 0.1 Width across flats K A + 2 stroke B + Stroke V H + Stroke D M E J E M 4 x N through 8 x O counterbore Width across flats K A
steel L LQ-GP 2 J 07 Tubing size symbol (Refer to Table 1) Body class (Refer to Table 1) Insert pin (Single) Insert pin material (J/K type only) Type Nil S Resin Stainless steel LQ-GH J 07 Holder (Single) Tubing size symbol (Refer to Table 1) Type Note1) Replacement part type J shows the parts for LQ-GJ and LQ-GK.
Stainless steel L LQ-GP 2 J 07 Tubing size symbol (Refer to Table 1) Body class (Refer to Table 1) Insert pin (single) Insert pin material (J/K type only) Type Nil S Resin Stainless steel LQ-GH J 07 Holder (single) Tubing size symbol (Refer to Table 1) Type Note1) Replacement part type J shows the parts for LQ-GJ and LQ-GK.
n d a d j u s t m e n t i s p o s s i b l e w i t h o u t d i s a s s e m b l y o f the manifold H O W T O O R D E R NZM V A C U U M E J E C T O R M A N I F O L D (N)ZZM B NUMBER OF STATIONS 01 ... 1 Station 02 ... 2 Stations to 10 ... 10 Stations EXHAUST PORT 04 ... 1/2 06 ... 3/4 PORT THREAD Nil ...PT* Remove (N) when ordering T .NPTF Fitted with an Optional Silencer Series NAN: see section
Series LVQ is a 2 port chemical valve with a non-metallic exterior. A high density PVDF housing offers increased chemical resistance and the special diaphragm construction insures gentle opening and closing preventing the formation of micro-bubbles. The LVQ guide ring eliminates lateral motion of the poppet, which reduces internal leakage.2 port chemical valve, Viper series (standard type
H J K P.C.D L1 8 x 8.4 L2 XMC-50 XMC-63 XMC-80 70 88 90 29 36 44 P.C.D 92.1 10.5 9 9 486 Stainless steel High Vacuum Angle/In-line Valve XMC, XYC Series Dimensions XYC-25, 40/In-line type C D G C B J H 45 E A Fn (KF flange) (mm) Model A 85 115 B 48 66 C 1 2 D 23.5 38 E 40 55 Fn G 64 84 H J XYC-25 XYC-40 100.2 130 26 41 28 36 XYC-50 to 80/In-line type C D G Fd XLA C XL (K flange) XLQ