SMC Corporation of America
Elite Part Number Search
Search Results "MGPL63TF-25AZ"

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: A96V, Lead Wire Length(m): 3, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: A96V, Lead Wire Length(m): 3, The number of the switches:

Bearing Type: L (Ball Bushing), Bore Size: 63mm, Thread Type: TF (G), Stroke: 50mm, Stroke Adjustment: A (0 to 10), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC8 (Adjustable Stroke, Extension Type)

Bearing Type: L (Ball Bushing), Bore Size: 63mm, Thread Type: TF (G), Stroke: 50mm, Stroke Adjustment: A (0 to 10), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC9 (Adjustable Stroke, Retraction Type)

Bearing Type: L (Ball Bushing), Bore Size: 63mm, Thread Type: TF (G), Stroke: 50mm, Stroke Adjustment: B (0 to 25), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC8 (Adjustable Stroke, Extension Type)

Bearing Type: L (Ball Bushing), Bore Size: 63mm, Thread Type: TF (G), Stroke: 50mm, Stroke Adjustment: B (0 to 25), Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC9 (Adjustable Stroke, Retraction Type)

Bearing Type: L (Ball Bushing), Bore Size: 63mm, Port Thread: TF (G), Stroke: 100mm, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scraper), Suffix: W (XC4, XC35: w/Scrapper Both Ends)

Bearing Type: Ball Bushing, Bore Size: 63mm, Port Thread: G, Stroke: 100mm, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: w/Heavy Duty Scraper, Suffix: XC4, XC35: w/Scrapper Both Ends

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: A96V, Lead Wire Length(m): 3, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: A96V, Lead Wire Length(m): 3, The number of the switches:

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: G, Auto Switches: M9P, Lead

Bearing Type: Ball Bushing, Bore Size: 63mm, Thread Type: G, Stroke: 50mm, Stroke Adjustment: 0 to 25, Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Stroke, Extension Type

Bearing Type: Ball Bushing, Bore Size: 63mm, Thread Type: G, Stroke: 50mm, Stroke Adjustment: 0 to 25, Auto Switch: A96V--Reed, DC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Stroke, Retraction Type

Magnet: D (Built-in), Type: Pneumatic, Mounting: D (Double Clevis), Bore: 20mm, Port Thread: Rc, Stroke: 25mm, Cushion: A (Air Cushion), Rod End Thread: Male Rod End, Rod Boot: None

Magnet: D (Built-in), Type: Pneumatic, Mounting: D (Double Clevis), Bore: 32mm, Port Thread: Rc, Stroke: 25mm, Cushion: A (Air Cushion), Rod End Thread: Male Rod End, Rod Boot: None

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead