Fixed end At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%. Max.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
in the users equipment: 25 kW Power supply: 200 V 60 Hz Circulating fluid flow: 125 L/min@0.5 MPa External piping: Bypass piping + Heat load 21 Conditions 20 19 25 kW load Heat load fluctuation (0 kW 25 kW) 0 kW load 0 10 20 30 40 50 Time [Minute] Applicable to an ambient temperature of 20C.
Safety standards CE marking, UL (NRTL) standards *1 Conditions: Circulating fluid set temperature 20C, Flow rate 3 L/min, Facility water temperature 20C, Flow rate 10 L/min, Ambient temperature 25C *2 The indicated values are with a stable load without turbulence in the operating conditions.
(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.
Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa 2 mounting types Ambient and fluid temperature Without auto switch: 20C to 80C (No freezing) With auto switch: 10C to 60C (No freezing) Front side mounting and bottom side mounting available to suit your applications.
After 15 minutes, cool 32C down to 20C.
Bore Size: 8mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Function: Standard, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bore Size: 8mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: Standard, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
65 65 Vertical 145 175 175 Standby power consumption when operating [W] Note 10) Horizontal 2 2 2 Vertical 8 8 8 Electric specications Max. instantaneous power consumption [W] Note 11) 445 724 724 Type Note 12) Non-magnetizing lock Holding force lbf [N] 29 [131] 57 [255] 109 [485] 35 [157] 69 [308] 132 [588] 44 [197] 87 [385] 165 [736] Lock unit specications Power consumption [W] at 68F (20C
of 20%, V 1120 [W] x 1.2 = 1344 [W] After 15 minutes, cool 32C down to 20C.
0.7 MPa Pressure 0.7 MPa 50 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 400 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 0.6 MPa 0.6 MPa 0.6 MPa 0.5 MPa 0.5 MPa 40 300 0.5 MPa 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 0.4 MPa 0.4 MPa 0.3 MPa 0.3 MPa 200 20 0.3 MPa 0.3 MPa 0.25 MPa 0.25 MPa 100 10 0 10 20 30 40 50 60 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) MHZ2-20C
20C (68F) bend the tubing into a U shape.
Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.
factor of 20%, 7.0 [kW] x 1.2 = 8.4 [kW] V After 15 minutes, cool 32C down to 20C.
After 15 minutes, cool 32C down to 20C.
O When the ambient temperature is 20C 5C and rated voltage is applied. P Coil change from AC to DC or DC to AC is impossible because the iron core shapes are different.
(at 20C) Data 10-12-9 9 Series CEP1 Proper Auto Switch Mounting Position Weight (Without mounting bracket/connector) (kg) Regarding dimensions for the proper auto switch mounting position (at stroke end), refer to page 1012-16.
After 15 minutes, cool 32C down to 20C. HRL200-A Precautions on Cooling Capacity Calculation 1. Heating capacity When the circulating fluid temperature is set above room temperature, it needs to be heated by the thermo-chiller. The heating capacity depends on the circulating fluid temperature.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) For details, please contact SMC.