SMC Corporation of America
Elite Part Number Search
Search Results "NCDGBN25-0100-XB13"

thread) Vertical mounting (Body thread) OUT Lateral mounting (Body thread) OUT port (On both sides) IN port (On both sides) IN port Application Example Useful when long stroke/travel is required Action MXH Workpiece Pitch moment Series Variations Standard stroke (mm) Model Made to Order 5 10 15 20 25 30 40 50 60 MXH6 -XC79 : Machining tapped hole, drilled hole and pin hole additionally -XB13

Low Speed Cylinder Heat Resistant Cylinder (150C) 2 1 MGG M XB13 Standard part number from page 1 MGG XB6 Standard part number from page 1 Heat resistant cylinder Low speed cylinder Slide bearing This is an air cylinder with seal and grease materials modified to allow operation at high ambient temperatures up to 150C.

The MGPM/L-XB13 is a compact body actuator integrated with internal guide shafts with the ability to operate smoothly at low speeds (5 to 50mm/s).

Double acting, single rod w/XB13, XC8, XC9, XC10 or XC11; Double acting double rod w/XC10; XB13 capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke with 3 positions (single rod type); Bore sizes (mm): 20

Note 2) Consult with SMC when units are used at a low speed (10 mm/s or faster) (when intermediate stops are not required) since -XB13 (Low speed specification) is available. Note 3) When using the air-hydro type, use the double side hydro unit.

Double acting, single rod w/XB13, XC8, XC9, XC10 or XC11; Double acting double rod w/XC10; XB13 capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke with 3 positions (single rod type); Bore sizes (mm): 20

Double acting, single rod w/XB13, XC8, XC9, XC10 or XC11; Double acting double rod w/XC10; XB13 capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke with 3 positions (single rod type); Bore sizes (mm): 20

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Example: Part Number *NVSA 4114-52AM =A |NVSA 4114.00A vatve mounled on *ISPA 0112 subplate with a #SPA 0100 Interlace Spaed Control between.

[PA04] = 0100. Set the "PA04" to "0100" in the "Basic" tab. Click on the "Single Axis Write" button. Turn the power OFF and ON again. Parameter is enabled. -24- 6.3.6 Absolute position detection system *If you use the absolute position detection system, set parameter: [PA03]=0001. Refer to "LECSS Operation Manual, chapter 12 for details.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com