This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 1.10231 lb, ModelApplicable fluidDetection methodRated flow rangeDisplay flow rangeSet flow rangeMinimum setting unitConversion of accumulated pulseFluid temperatureDisplay unitAccuracyRepeatabilityTemperature
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, IFW/PFW NO SIZE ALL OTHER, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 1.10231 lb, ModelApplicable fluidDetection methodRated flow rangeDisplay flow rangeSet flow rangeMinimum setting unitConversion of accumulated pulseFluid temperatureDisplay unitAccuracyRepeatabilityTemperature
.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C)
.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C)
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 06 (3/4), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket
.: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: -
.: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor , Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor , Temperature Sensor: Temperature Sensor, Lead Wire: w/M12-M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 1.87993 lb, ModelApplicable fluidDetection methodRated flow rangeDisplay flow rangeSet flow rangeMinimum setting unitConversion of accumulated pulseFluid temperatureDisplay unitAccuracyRepeatabilityTemperature characteristicsOperating
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .00000 lb, ModelApplicable fluidDetection methodRated flow rangeDisplay flow rangeSet flow rangeMinimum setting unitConversion of accumulated pulseFluid temperatureDisplay unitAccuracyRepeatabilityTemperature characteristicsOperating
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC