Valve Stations: 4 Stations, Port Size: N11 (ø3/8" One-touch Fitting), Thread: T (NPT/NPTF), SI Unit: WS (Wireless Remote Unit), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)
Stations: 08 Stations, Port Size: C6 (w/ø6 One-touch Fitting), SI Unit: WS (Wireless Remote), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM)
Valve Stations: 8 Stations, Port Size: 03 (3/8), Thread: Rc, SI Unit: WS (Wireless Remote Unit), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)
Valve Stations: 11 Stations, Port Size: 03 (3/8), Thread: N (NPT), SI Unit: WS (Wireless Remote Unit), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A)
Valve Stations: 4 Stations, Port Size: 03 (3/8), Thread: T (NPT/NPTF), SI Unit: WS (Wireless Remote Unit), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)
Stations: 04 Stations, Port Size: N7 (w/ø1/4" One-touch Fitting), SI Unit: WS (Wireless Remote), End Plate: 3 [Power Supply w/7/8" Connector (Max. Supplied Current 8 A)], SI Unit Common: N (-COM)
D-F7BV D-F7BAL, D-J79W D.A72,D-A72H B i r w n l 8 t u w n (Black) D.F7PW D-E80A D-E73A (Black) o Reed swil.h o e Beed swltch Brue :Ei*" lblack) ked) D.A76H. D-E75A (+) E | 'FesisLort Black ;fi-+4--lrl" (-) o Series NCX2 6.14 10.14 Aub sr.
1 Output RoHS 3-Screen Display High-Precision Digital Pressure Switch IP40 ZSE20(F)/ISE20 Series How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range e Unit specification w Output specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description N NPN open collector 1
Simple Setting Mode Press the and buttons 1 second or longer to recover from error. Try copy function after checking wiring, product model etc. NOTE Copy error Fail to operate copy function. (1) Press and hold the button between 1 and 3 seconds in measurement mode. [SEt] is displayed on the main display.
Simple Setting Mode Press the and buttons 1 second or longer to recover from error. Try copy function after checking wiring, product model etc. NOTE Copy error Fail to operate copy function. (1) Press and hold the button between 1 and 3 seconds in measurement mode. [SEt] is displayed on the main display.
Zero-clear function In measurement mode, when the and buttons are pressed for 1 second or Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.
Set value P_1 Hysteresis H_1 Piping Tightening the connection thread For connecting to the body (piping specification: -M5) After hand tightening, apply a spanner of the correct size to the spanner flats of the piping body, and tighten with a 1/6 to 1/4 rotation. As a reference, the tightening torque is 1 to 1.5 Nm.
This is a legacy product, and replaced byAS2201F-N01-07S, INVALID P/N (SGL P/N SYST *LQA, AIRLINE EQUIPMENT, AS***F 1/8INCSTANDARD (NPT), .03968 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air tube, 3 cores
1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?
1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?
Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: T (w/o Operation Manual, Calibration Certificate)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)