9 16 MXP16-PS 8-8-13 13 Series MXP Dimensions: MXPJ6 4-M3 x 0.5, depth 3 7 5 H 3 18 1 0.05 D B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3.5 16.5 14 13 20 6 F 6 6 5 Piping port 2-M4 x 0.7 13.5 Bottom hole diameter 3.3 2-M3 x 0.5 17 0.05 (Plug: M-3P) Mounting
X m3 x g m2 x g Vertical mounting Mounting orientation Horizontal mounting Ceiling mounting Wall mounting Vertical mounting M3 Static load (m) m1 m2 m3 m4 Note) M1 Static moment M1 m1 x g x X m2 x g x X m4 x g x Z z y M2 m1 x g x Y m2 x g x Y m3 x g x Z Y Z M3 m3 x g x X m4 x g x Y m4 x g Note) m4 is a mass movable by thrust.
x 0.93 x 1 x 0.88) = 0.51 m3/min 3 Selecting a model According to the corrected air flow capacity of 0.43 m3/min, IDF4E will be selected which air flow capacity is 0.52 m3/min at 50 Hz.
Bore size NTJ-010A NTJ-006A 8 6 M3 x 0.5 2.4 5.5 6.4 5.5 6.5 M3 x 0.5 6 12.5 M4 x 0.7 3.2 7 8.1 7 8.5 M4 x 0.7 8 14.5 NTJ-015A 10 M5 x 0.8 4 8 9.2 10.5 M5 x 0.8 16.5 10 9 (mm) Standard C D E F B A J K L M N O P G H I Bore size 8 6 M2.5 x 0.45 13 7 7 10 9 19 3 5 4 9 3.5 8 7 5.3 24 M3 x 0.5 13 7 8 11 10 21 3 6 5 11 4.5 10 8 5.3 25 10 13.5 M3 x 0.5 7 8.5 11.5 10.5 22 3.2 6 6 12 5 11 8.5 5.6
ALARM 24 Alarm output NO. 3 13 NO. 4 4 COM 12, 25 Common The output terminal common.
x 0.5 thread depth 4 (Mounting thread) 15 3H9 depth 3 +0.025 0 13H9 depth 1.5 +0.043 0 2-M3 x 0.5 thread depth 6 (Mounting thread) 4-M4 x 0.7 thread depth 8 (Mounting thread) Bottom hole 3.4 through (Mounting hole) 0 0.1 5 Open 13 +1.2 0 4 8 10 0.02 32.6 28 34 22 20 0 0.2 Closed 9 22 3H9 depth 3 +0.025 0 15 31 13 63 20 0.05 Auto Switch Mounting Groove Dimensions 4-M3 x 0.5 (Thread for
17.5 M3 x 0.5 (Finger opening port) MHKL2-12: Long stroke type 9 2-M3 x 0.5 thread depth 5 (Mounting thread) 20 3H9 depth 3 +0.025 0 13H9 depth 1.5 +0.043 0 2-M3 x 0.5 thread depth 6 (Mounting thread) 4-M4 x 0.7 thread depth 8 (Mounting thread) Bottom hole 3.4 through (Mounting hole) 0 0.1 5 Open 20 +1.2 0 4 8 10 0.02 41.6 30 20 3 22 43 0 0.2 Closed 9 26 3H9 depth 3 +0.025 0 15 36 13 57
X 0.5 thread 4 deep 15 3H9 3 deep +0.030 0 2-M3 X 0.5 thread 6 deep 13H9 1.5 deep +0.043 0 4-M4 X 0.7 thread 8 deep Bottom hole dia. 3.4 through-hole 0 -0.1 5 Open 13 +1.2 0 4 8 10 0.02 32.6 28 34 22 20 0 -0.2 Closed 9 22 3H9 3 deep +0.030 0 15 31 13 63 20 0.05 Groove position for auto switch mounting 4-M3 X 0.5 (Attachment mounting thread) M3 X 0.5 (Finger closing port) Groove position
10.4 4.5 24.5 M A L H 8 1/8 KQ2H08-01GS 14 12.4 13 22.5 19.4 14.2 26.1 18 6 11.9 1/4 KQ2H08-02GS 14 12.4 13 22 17.3 14.2 26.1 18 6 13.9 3/8 KQ2H08-03GS 17 17 13 18.1 13 14.2 26.1 18 6 21 Connection thread (With sealant) 1/8 KQ2H10-01GS 17 14.8 15.6 23.8 20.7 15.6 26.1 26.1 6 16.9 1/4 KQ2H10-02GS 17 14.8 15.6 27.3 22.6 15.6 41.5 29.5 7.5 22.1 3/8 KQ2H10-03GS 17 14.8 15.6 23.5 18.4 15.6
L Dimension n: Stations L n 2 135.5 125 102.6 16.5 63 3 148 137.5 113.1 17.5 73.5 4 148 137.5 123.6 12 84 5 160.5 150 134.1 13 94.5 6 173 162.5 144.6 14 105 7 185.5 175 155.1 15 115.5 8 198 187.5 165.6 16 126 9 210.5 200 176.1 17 136.5 10 210.5 200 186.6 12 147 11 223 212.5 197.1 13 157.5 12 235.5 225 207.6 14 168 13 248 237.5 218.1 15 178.5 14 260.5 250 228.6 16 189 15 273 262.5 239.1 17
M2 M3 m1 m2 m3 16 25 40 16 25 40 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 100 120 100 38 35 35 MY2HT 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
) 17 11-4 () () ONOFF 11-5 1-1 IDU Series 11-4 11 2 IDX-OM-W023 12.S 12 S 12-1 IDU8E15E1-10 IDU Series 12-1 IDX-OM-W023 12.S 12-2 L N PE M3 6.5mm 2 1.25mm 12-3 1-1 IDU Series 12-2 IDX-OM-W023 13 T 13 T 13-1 IEC 13-2 AC200V / 2A DC24V / 2A ( 20V / 5mA) 13-3 ON 3 () 5 /1 () IDU Series 13-1 13 1 IDX-OM-W023 13 T 13-4 1 PE L N 3 2 L,N: PE: LN PE M3 (0.63Nm) 6.5mm
MHY MHW Option JIS Symbol Double acting MRHQ Body Option/End Boss Type Type of piping port MHCA2-6 M3 x 0.5 M3 x 0.5 With 4 one-touch fitting With 4 hose nipple M3 x 0.5 Symbol Piping port location Applicable model Misc.
MHY MHW Option JIS Symbol Double acting MRHQ Body Option/End Boss Type Type of piping port MHCA2-6 M3 x 0.5 M3 x 0.5 With 4 one-touch fitting With 4 hose nipple M3 x 0.5 Symbol Piping port location Applicable model Misc.
S) (mm) Dimensions (mm) Dimensions W W Model LVA20 LVA30 LVA40 LVA50 LVA60 S Model LVA2 LVA3 LVA4 LVA5 LVA6 66.5 11.5 89.5 24 110 29 A B A B 140.5 34.5 148 36 Dimensions (mm) A B Q R P C E F G H K L N Model LVA1 20 33 49.5 10 M5 x 0.8 27.5 11 13 27.5 4.2 Rc 1/8, 1/4 NPT 1/8, 1/4 M5 x 0.8 LVA2 30 33 57 10 M5 x 0.8 31 13 22 22 26 M3 x 0.5 Rc 1/4, 3/8 NPT 1/4, 3/8 LVA3 36 47 13 M6 x 1.0 42.5
Drain 13 Compressed Air Preparation Filter AFF/AM/AMD Series Construction: AFF, AM, AMD Bowl Assembly/Part Nos.
) 12-4 () () ONOFF 12-5 1-1 IDF Series 12-4 12 2 IDX-OM-W011 13.S 13 S 13-1 IDF1E15E1-10 IDF Series 13-1 13-1 IDX-OM-W011 13.S 13-2 IDF1EIDF3E L N PE M3 6.5mm 2 1.25mm IDF4E15E1 L N PE M3 6.5mm 2 1.25mm 13-3 1-1 IDF Series 13-2 13-2 I D XO M W 011 14 T 14 T I D F4E/6E/8E/11E/15E1 141 I EC 142 AC200V / 2A D C24V / 2A ( 20V / 5m A) 143 O N 3 ( ) 5 /1 ( )
1/8" 7.2 17.2 21.7 16.9 5 AS121F-M3-03A-X790 5/32" 8.2 M3 x 0.5 8 9.4 26.5 25.4 23.5 22.4 1 Reference dimensions 2 Reference dimensions of threads after installation 13 JMGP Series Specific Product Precautions 1 Be sure to read this before handling the products.
0 2H9 depth 3 4-M3 x 0.5 thread depth 5.5 (mounting thread) 0.02 5.2 Prepared hole dia. 2.6 through (mounting hole) Note) +2.2 0 0 -0.1 4 16 29 23 18 7.6 0.02 11H9 depth 2 +0.043 0 0 -0.7 23 12 When closed 11.2 When open 15.2 16.4 0.05 37.8 6 12 2-M3 x 0.5 thread depth 6 (mounting thread) 57 M3 x 0.5 4-M2.5 x 0.45 (finger closing port) (attachment mounting thread) M3 x 0.5 (finger opening