SMC Corporation of America
Elite Part Number Search
Search Results "VHS5510-10A-S-X1"

M8 Connector 3 5 Polar type (Standard) With surge voltage suppressor (S) 3 5 Polarity protection diode (There is no S option, because the generation of surge voltage is prevented by a rectifier.)

-5 VVQZ200-10A-5 VVQZ300-10A-5 Use to reserve a valve mounting space on the manifold for furture use.

Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.

Other dimensions are the same as the grommet type. 3-7-12 13 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series VZS2000 Non Plug-in 2 position double, 3 position closed center/exhaust center/pressure center Grommet 2 position double: VZS2250-G H(S)-01 3 position closed center: VZS2350-G H(S)-01 3 position exhaust center: VZS2450-G H(S)-01 3 position pressure center

Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58

ground Power supply {24 V 0 V The above is the example of using dedicated S-LINK flat ribbon cable SL-RCMl00.

Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58

Refer to the table (3) for the available combinations between each electrical option (S, L, Z) and rated voltage.

VNA1A -6A, 8A, 10A VNA2 -10A, 15A VNA3 -20A VNA4 -25A VNA5 -32A VNA6 -40A VNA7 -50A No.

Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.

DENMARK SMC Pneumatik A/S FINLAND SMC Pneumatiikka OY FRANCE SMC Pneumatique SA GERMANY SMC Pneumatik GmbH HUNGARY SMC Hungary Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. NETHERLANDS SMC Pnuematics BV. NORWAY SMC Pneumatics Norway A/S ROMANIA SMC Romania s.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Slovakia s.r.o. SLOVENIA SMC Slovenia d.o.o.

Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.

Note 3) 200 to 240VAC is "S" specification standard. Note 4) Combinations of M and H, H and M, R and S, S and T, L and M are not available.

-5 (VQZ1000) VVQZ2000-10A-5 (VQZ2000) VVQZ3000-10A-5 (VQZ3000) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.

) 1 8 2 x (Back side 10(P2)) VNA P1 4 x P S VNB F U D E SGC Bracket (Option) A B 15 SGH VNC 1(A) (Back side 2(B)) Main port T C Port size: refer to table below A B VNH VND VND Main port 1(A), 2(B) A B C D E F G M N P Q R S T U Model VCC VND20D-10A VND20D-15A VND30D-20A VND40D-25A 3 8 1 2 3 4 1 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 TQ 80 90 50 60 35 44 17.5 22 85 101 93 109 5

(value under the prescribed conditions) 2 1/4 ( 8A) 1/4 ( 8A) VCW (for water) 2 port solenoid valve NBR (FKM) (EPDM) (PTFE) 3 3/8 (10A) Brass (Stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is N.C. (normally closed) only. OUT OUT IN IN N.C. N.O. 100 Electrical Terminology 1.

Electrical option Nil S L Z VDW None With surge voltage suppressor With indicator light With light/surge voltage suppressor VQ Body size 3 4 5 6 7 8 9 10A 15A 20A 25A 32A 40A 50A VX2 Refer to the table (2) given below for availability.

(value under the prescribed conditions) 2 1/4 ( 8A) 1/4 ( 8A) VCW (for water) 2 port solenoid valve NBR (FKM) (EPDM) (PTFE) 3 3/8 (10A) Brass (Stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is N.C. (normally closed) only. OUT OUT IN IN N.C. N.O. 100 Electrical Terminology 1.

34 LVQ D LQ LVN U 25 R C 44 TI/ TIL C R G1/2 PA E E G1/2 PAX B B 2-P Port size A A D 2-P Port size (S) PB Port size G1/2 Compatible heavy-duty cord Cable O.D. 6 to 12 L L K 2-M Thread depth 6 K 2-M Thread depth 6 (mm) Electrical entry P Port size B Model A C D E F K L M Grommet: G Conduit: C DIN terminal: D Conduit terminal: T S 68 71 74 74 U 81 91.5 101 103.5 S 51 54 57 57 Q 98 101 104 104

R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.