This is a legacy product, and replaced byVF3343-5DZ1
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The series may be used as either a selector valve, or a divider valve. It is vacuum applicable up to –101.2kPa. Series VP3145/3165/3185 is a large size, 3 port solenoid valve with a rubber seal. It is possible to use the series in vacuum
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Connection L2 M d A Effective area (mm2) Weight (g) L1 thread R Model 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
The load ratio is obtained by the following formula: ((Load mass x 9.8)/Theoretical output) x 100% Conditions MB, CA2 series CS1, CS2 series Series Condition 10A x 1 m SGP (Steel pipe) dia. x Length VQ4100--03 VQ4101--03 AS420-03 Speed controller AN30-03 Silencer 10A x 1 m SGP (Steel pipe) dia. x Length VQ5100--04 VQ5101--04 AS420-04 Speed controller AN40-04 Silencer 448 INDEX Page 446 Base
less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Leakage current 100 A or less at 24 VDC 0.8 mA or less Indicator light Red LED illuminates when turned ON.
D2 L1 L2 L3 P Q1 Q2 A MB MA tube O.D.
Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 kW = 6 V Example: Load impedance is 3 kW. Leakage current from auto switch is 1 mA.
Load current 5 to 40 mA 40 mA or less 80 mA or less Operating Precautions 1.5 V or less (0.8 V or less at 10 mA load current Internal voltage drop 4 V or less 0.8 V or less Do not use anything other than the mounting screws attached to the auto switch body to secure the switch.
How to order lead wire length (Example) L D-F9P Specifications Nil Lead wire length 0.5 m 3 m 5 m L Z CD-P11 CD-P12 24 VDC 50 mA 200 VAC 12.5 mA 100 VAC or less 25 mA Part no.
28 VDC or less 40 mA or less 2.5 to 40 mA Load current 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating position .
12-6 6 85 55 44 8 12 11.5 22.5 35.5 24 34.5 15.5 14.7 18.5 22 9 KM11-08-12-10 10 116 86 62 L5 FB N L1 L2 L3 L4 L6 P Q1 Q2 MA MB FA B Port Min Weight Model Inside Dia (g) (Inch Size) 19.5 6 10.6 5/16 65 10 18 29.5 27 40 12 16 18.5 5/32 6 22 KM11-03-09-6 19.5 5/16 10 86 10 18 29.5 27 10.6 61.5 12 16 18.5 5/32 6 30 KM11-03-09-10 21.5 3/8 6 77.8 10 19.5 31.5 30.5 13.3 48 13 17 21 1/4 7 32 KM11
Load voltage 24 VDC, 100 VAC 24 VDC, 100 VAC, 200 VAC 24 VDC (10 to 28 VDC) 24 VDC (10 to 28 VDC) 28 VDC or less 28 VDC or less Load current range Indicator light Type Auto switch model D-C73 D-B54 D-H7B D-K59 D-H7A1 D-G59 Application Relay, PLC Relay, PLC 24 VDC relay, PLC 5 to 40 mA, 5 to 20 mA Reed switch 5 to 50 mA, 5 to 25 mA, 5 to 12.5 mA 5 to 40 mA 5 to 40 mA 40 mA or less 40 mA or