<br><br>Meter-in control is a control method in which the speed of the cylinder is controlled using the cylinder supply flow rate.<br>With meter-in control, the exhaust conditions do not affect operation, and the piston can start moving quickly. (Cylinder lurching can be prevented.)
<br>Note) The accuracy will decline if IN side piping deviating from the recommended straight piping length or bore size is used.<br><br>
<br>The VX3 series catalog can be found here.<br><br>
<br>Be sure to check the specifications and precautions listed in the catalog of each type of tubing and fitting. <br>Note that LQ series piping requires a special tool. <br><br><br><br>Fittings and tubing catalogs can be found here.
<br>In this case, use the bypass piping set (optional accessory) to secure the flow rate. <br>Note) The temperature stability is as follows: ±2.0℃ for the HRSE, ±0.5℃ for the HRS090, and ±1.0℃ HRS100/150/200.<br><br>
<br>First, refer to the “Transport and Setting Up” section in the HRS series operation manual. <br>Wiring examples are shown in the “Wiring of remote operation signal input” and “Wiring of run/stop signal input・Remote signal input” sections. <br>Next, to enable remote signal input, change the communication mode from “LOCAL” to “DIO” mode.
<br>Please check the figure below. If the product is equipped with a control power supply, this control power supply circuit is provided. <br>If the operating power supply voltage is energized while the valve is open, it is acceptable not to drop it to the holding voltage.<br><br>
Manifold specifications Model SS5Z3-60 Manifold type Non-plug-in type P(SUP), R(EXH) system Common SUP, EXH Valve stations 2 to 20 stations Location Valve A, B port piping specifications Direction Lateral C8 P, EA, EB ports Port size C4, C6, M5 A/B ports PA/B 3.4 (0.19) C4 A/BR 3.2 (0.18) Valve effective area mm (Cv value) PA/B 3.7 (0.21) C6 A/BR 3.9 (0.22) PA/B 3.4 (0.19) M5 A/BR 3.2 (0.18
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: DIN Terminal w/Connector, Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Push-turn Locking Lever Type, Port Size: 3/8, Thread: NPT, Made to Order: -, CE Approval:
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: DIN Terminal w/Connector, Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Push-turn Locking Lever Type, Port Size: 3/8, Thread: -, Made to Order: -, CE Approval: -
Function: 2 Position Single, Piping: Body Ported, Exhaust: Individual, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: DIN Terminal w/Connector, Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Push-turn Locking Lever Type, Port Size: 3/8, Thread: NPT, Made to Order: -, CE Approval:
Function: 2 Position Single, Piping: Body Ported, Exhaust: Individual, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: DIN Terminal w/Connector, Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Push-turn Locking Lever Type, Port Size: 1/4, Thread: NPTF, Made to Order: -, CE Approval:
Function: 2 Position Single, Piping: Body Ported, Exhaust: Individual, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: DIN Terminal w/Connector, Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Push-turn Locking Lever Type, Port Size: 1/4, Thread: NPT, Made to Order: -, CE Approval:
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: E (Push-turn Locking Lever Type), A, B Port Size: 02 (1
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: E (Push-turn Locking Lever Type), A, B Port Size: 02 (
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: E (Push-turn Locking Lever Type), A, B Port Size: 02 (1
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: E (Push-turn Locking Lever Type), Port Size: 03 (3/8), Thread: N (NPT)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: E (Push-turn Locking Lever Type), Port Size: 03 (3/8)