03 C10 02 03 C12 Enter only when using for a 2 position single or double.
KPGU10-02 KPGU10-03 KPGU12-03 KPGU12-04 KPQU04-M5 KPQU04-01 KPQU04-02 KPQU06-M5 KPQU06-01 KPQU06-02 KPQU08-01 KPQU08-02 KPQU10-02 KPQU10-03 KPQU12-03 KPQU12-04 40.7 42.3 46.7 43.9 45.5 49.9 53.6 59.1 62.3 59.2 64.9 69.5 10 11 20 12 11 21 15 23 30 40 40 65 11 37 4 17 4 4 10.4 10.4 KDM 14 41 M 13 40.5 6 18.5 10 10 12.8 12.8 KB 8 A L 14 44.5 48.5 53.5 57 54 59.5 62.5 4.2 8 17 15.2 20.5 26 18
Note 9 Gray Black 22 Pink Red Station 9 SOL.B 1.5 m 3 m 5 m AXT100-DS25-015 AXT100-DS25-030 AXT100-DS25-050 SOL.A 10 White Black Cable 0.3 mm2 x 25 cores Station 10 SOL.B 23 Gray Red 11 White Red SOL.A Station 11 When using a standard commercial connector, use a type 25P female connector conforming to MIL-C-24308. Cannot be used for transfer wiring.
(This is not applicable to VHS40) Body Size Symbol Port Size Body Size 20 30 40 02 03 04 1/4 3/8 1/2 Effective area (mm2) 5 5 Model VHS20 VHS30 Note: Other sizes, thread forms, options, etc. may be possible, please contact SMC for availability.
3 i Meter-in type Meter-in type AS3211F-02 AS3311F-02 AS ASP ASN AQ ASV AK ASS ASR Component Parts Component Parts No. Description Material Note No.
Delivery pressure Code 1 to 30 psig (0.007 to 0.2 MPa) 2 to 60 psig (0.014 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) 5 to 150 psig (0.034 to 1.0 MPa) 02 06 10 15 Bonnet Standard Panel Installation 3) Bonnet port (NPT 1/8 inch) Code No code P BP Material 3) Panel mounting hole: dia.39.6 mm.
Valve mounting direction ( ) 02 2 stations Single solenoid coil is located on the opposite side of the A, B port. -: : Single solenoid coil is located on same side as the A, B port.
Series SV2000 for EX120 Dedicated Output Serial Wiring. 6 7 8 10 10 10 10 10 10 10 11 11 11 11 11 11 12 12 13 13 13 15 16 16 17 19 20 21 21 23 23 24 24 24 24 24 25 26 27 27 30 30 31 32 33 34 35 36 37 37 39 40 40 41 42 44 45 45 50 50 51 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
terminal (D): SYJ5220-D-M5 M8 connector (W0): SYJ5220-W0-M5 Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 Max. 10 28.1 [35.1] 60.9 53.4 12.7 M8 x 1 32.6 42.1 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 20 20 20 20 107 [111.4] 3 3 3 3 87.4 [91.8] 105.2 125.2 90.4 77.4 45.4 127 11 11 11 11 23 2-2.6 (For mounting) 2-2.6 (For mounting) 2-2.6 (For mounting) 23 23 23 27
2 stations N SD Note 2) SU Note 2) 11 11 stations W Note 1) Add 1 station for terminal block box mounting.
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
type GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS Pressure gauge G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02 Round G46-2-02 G46-2-02 0.2MPa Note 4) Square embedded type GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.
M1 M2 Weight (g) ASV310F-01-06S ASV310F-01-08S ASV310F-02-06S ASV310F-02-08S ASV410F-01-08S ASV410F-01-10S ASV410F-02-08S ASV410F-02-10S ASV410F-03-08S ASV410F-03-10S ASV510F-02-10S ASV510F-02-12S ASV510F-03-10S ASV510F-03-12S ASV510F-04-10S ASV510F-04-12S 71.9 73.8 71.9 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.8 90.2 91.8 90.2 91.8 16.8 19.3 16.8 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3
)VXA2130-02 4.1-59 VXA21/22 Dimensions (Orifice size 3 mm, 4.5 mm, 6 mm) VXA212m, VXA213m, VXA223m, VXA224m Model Port size P Rc(PT) A B C D E F With bracket G H I J VXA21 VXA22 , , 18 21 9 10.5 40 45 21 27 55 62 64 71 11 13 36 46 46 56 1 4 3 8 10 1 8 1 4 VX 11.5 VNl Dimensions (Orifice size 8mm, 10mm) VXA225m, VXA226m VQ Thread fixed: (VXA226 2 0 -04 0nly) Bracket E Port size Rc(PT) Model
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge temp. drop 4 High circulating fluid return temp. 5 High circulating
VFRA3111-03 VFRA3211-02 VFRA3211-03 VFRA3311-02 VFRA3311-03 VFRA3411-02 VFRA3411-03 VFRA3511-02 VFRA3511-03 1/4 3/8 1/4 3/8 1/4 3/8 1/4 3/8 1/4 3/8 0.38 0.39 0.41 0.36 0.40 0.39 0.42 0.42 0.33 (0.48) 0.34 (0.47) 1.9 2.2 1.9 2.0 1.8 1.9 1.7 1.8 1.9 (0.69) 2.2 (0.69) 0.61 Single 1/8 2 position 0.71 Double 1/8 Body ported Closed center 0.72 1/8 Exhaust center 0.72 1/8 3 position Pressure center
1/4, 1/8 port (A port) 25 12 12 G: Approx. 300 H: Approx. 600 (Lead wire length) 48.5 70.7 [72.9] A 18 20 27 34 R P Manual override 2-4.5 (For mounting) 40 4 (Light/surge voltage suppressor) M5 x 0.8 (SYJ714R: X port) + 58 [65] 54.5 42.6 26 20 X 1/4, 1/8 (P, R port) 23 15 48 L plug connector (L): SYJ74-LM plug connector (M): SYJ74-M01 02 01 02 DIN terminal (D): SYJ74-D01 02 M8 connector
15 (Bracket) VR VH 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 VHS 10 9 36 7.1 2-M3 x 0.5 (Pilot port) 10 1.8 4 A B (For mounting) 2-3.2 1.5 1.5 22 7 8.2 2.5 (For manifold mounting) 2-1.8 2-M3 x 0.5 (Pilot port) A B 11 1.5 17.5 (For mounting) 2-3.2 equivalent (18.5) A B Manual override 14 36 (18.5) (21) Manual override 41.6 13.5 15 41.6 28.5 21 R2 P R1 13 R P R (11)
--X693 PFM7S-01/02--X693 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 36.3 C6 6 10.3 8.3 C8 8(5/16) 12 37 C8 8(5/16) 12 10 N7 1/4 10.3 36.3 N7 1/4 10.3 8.3 PFM7-01/02--X694 PFM7S-01/02--X694 A B
Common exhaust: VV3P3-41Stations 1-02 (G) (E) (T) (D, Y) N.C. N.O.