Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 Adjustment of Cushion Effect (Smooth Start-up, Soft Stop) Caution Since the external slider and piston slider are directional for size 10, refer to the drawings below when performing disassembly or maintenance.
AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
(mm) Rod Flange Symbol F GB B A AL B1 C D FT FX FD ZZ E GA H H2 H1 I J MM KA NA P S Bore size (mm) 20 25 32 40 50 63 80 100 12 15 15 20.5 26 26 32.5 32.5 14.5 17.5 17.5 23.5 29 29 35.5 35.5 8 10 12 14 18 18 22 26 12 14 18 25 30 32 40 50 5 6 6 8 11 11 13 16 79 85 87 93 121 121 151 152 40 44 53 61 76 92 104 128 13 17 17 19 27 27 32 41 14 16.5 20 26 32 38 50 60 2 2 2 2 2 2 3 3 28 32 38 46 58
(Only for EX510-S 02 ) : Only mounting direction of the SI unit to the mounting bracket is different between EX510-S A and EX510-S B. Mounting direction can be changed from horizontal to vertical by changing the screws which construct the mounting bracket.
E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)
RCSK-o15 RCSK-02 RCSK-03 RCSK-04 BCSK-05 RCSK-O5 RCSK-08 RCSK-10 Double Hod clevi6 w/ oin(1). retainina rinos{2) RCDK-015RCDK.02 RCDK{3 RCDK-04 RCDK.OS RCDK.05 RCDK-08 RCDK.lO 'Jah nul sold separatly 'For accessory parl dimensions see cat.
For driver of 200 to 7kW, built-in regenerative resistor is used. 02: LEC-MR-RB-032 03: LEC-MR-RB-12 12 10 12. OPTIONS AND AUXILIARY EQUIPMENT (4) Connection of the regenerative option POINT For the sizes of wires used for wiring, refer to section 12.6. The regenerative option will cause a temperature rise of 100 relative to the ambient temperature.
Type 20 (5 Port/Body ported) How to Order Applicable solenoid valve M5 C4 C6 M5 C4 C6 SS5YJ520 05 SYJ520-A, B port M5 x 0.8 SYJ523-Applicable blanking plate assembly SYJ5000-21-1A Applicable individual EXH spacer assembly SYJ5000-17-1A P, R port thread type Number of stations -+ -+ P port 1/8 02 2 stations R R P Nil 00F 00N 00T Rc G NPT NPTF : : 20 20 stations R port 1/8 Type 40 (5 Port/
A A1 MM U1 L1 RR1 A1 L1 E1 MM RR1 U1 0.4 0.2 + 0.2 + 0 0.2 0.4 0.2 0.4 10 12 16 20 +0.002 0 5 6.4 8 10 0.2 0.4 0.1 0.3 0.2 0.4 0.2 0.4 +0.002 0 5 6.5 8 10 #8-32UNC 10 12 16 20 12 16 20 25 10 12 16 20 14.6 16.6 21 25.6 RCS-01 RCS-015 RCS-02 RCS-025 RCD-01 RCD-015 RCD-02 RCD-025 21.5 32 34 41 6 6 6 8 16 25 25 30 #8-32UNC #8-32UNC #10-32UNF 1/4-28UNF 6.3 12 10.3 18 7 14 11.5 14
RCSK-o15 RCSK-02 RCSK-03 RCSK-04 BCSK-05 RCSK-O5 RCSK-08 RCSK-10 Double Hod clevi6 w/ oin(1). retainina rinos{2) RCDK-015RCDK.02 RCDK{3 RCDK-04 RCDK.OS RCDK.05 RCDK-08 RCDK.lO 'Jah nul sold separatly 'For accessory parl dimensions see cat.
Valve mounting direction ( ) 02 2 stations Single solenoid coil is located on the opposite side of the A, B port. -: : Single solenoid coil is located on same side as the A, B port.
Sub-plate Nil Without sub-plate 02 With sub-plate (port size: 1/4) Sub-plate single type VQ2000 PW 02 Dimensions 4 2-4.5 mounting hole 89.4 Manual override Indicator light VQ210 --02 37 45 5 121 (DC) 130.1 (AC) 22.4 (86.3) (AC) 15.5 (77.1) (DC) Clamp screw M5 x 0.8 External pilot port 78.5 (AC) 72.6 (DC) 70.7 25 25 25 15.4 12 5 2.5 14.5 19.5 G 3/8 Electrical entry 43.8 39.1 53.6 IP65
Fluorine free series Construction and Parts (N)CQ2 Compact Cylinder type page series Standard Double acting Large bore Long stroke Non-rotating rod Single acting (N)CQ2(K) 2 (N)CQ2 31 S T Double Rod Standard Non-rotating rod (N)CQ2W (N)CQ2KW 49 67 Axial Piping Double acting Single acting CQP2 CQP2 77 83 S T CQ2 91 Water Resistant R V CQ2wS 103 High Lateral Load CBQ2 113 End Lock 10-CwQ2 121
Regarding the long stroke which exceeds the stroke range, refer to page 7-6-121 for the long stroke type of either CQ2 or CQS. Note 4) When ordering foot bracket, order 2 pieces per cylinder. Note 5) Parts belonging to each bracket are as follows.
Applicable bore size (mm) Dd9 d H B C m t d L l 12 16 20 25 32, 40 50, 63 80 100 IY-G012 IY-J015 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 Type C5 for axis Type C5 for axis Type C8 for axis Type C10 for axis Type C10 for axis Type C14 for axis Type C18 for axis Type C22 for axis NTJ-015A NT-015A NT-02 NT-03 NT-04 NT-05 NT-08 NT-10 12 16 20 25 32, 40 50, 63 80 100 0.030 0.060 0.030 0.060 0.040
Bus off detection Check the terminating resistor (121 ) is installed at both ends of the trunk line. Install the terminating resistor (121 ) properly. Keep noise sources away from DeviceNet cables and power cables. Check that there is no noise source or high voltage line around the DeviceNet cables and power cables.
YES NO NO 2 YES YES NO NO YES 10 2-2 (CEU2) (AC100V,15) (24V10,0.4A) (0.3MPa0.5MPa) 3) () (CE1-R**) (CE2**) 11 2-3 40 VFS240R VFS210 AR425 8/6 AN200-02 AS4000-02 50 VFS240R VFS210 AR425 10/7.5 AN200-02 AS4000-02 63 VFS340R VFS210 AR425 12/9 AN300-03 AS4000-03 80 VFS440R VFS310 AR425 12/9 AN300-03 AS420-03 100 VFS440R VFS310 AR425 12/9 AN400-04 AS420-04 12 * 3. 3-1 () 40 50 63 80
IDG60S to IDG100S IDG3 to IDG50 IDG3H to IDG50H IDG30L/ IDG50L Port size With separator regulator Symbol Bore Size 3 5 10 20 30 50 60 75 100 V IDG60 to IDG100 IDG60H to IDG100H IDG60L to IDG100L 01 1/8 02 1/4 IDG60S to IDG100S Note) Note) 03 3/8 04 1/2 Note 1) Specifications with element service indicator are also available. See the order made section on page 33.
In the case of pad direct mounting In the case of rod end male ZPT U N 02 B4 ZP U N 04 X11 Vacuum entry (Mounting thread diameter) Pad dia. (mm) Pad dia. (mm) Thread dia.