SMC Corporation of America
Elite Part Number Search
Search Results "ZSE10-N01-B-P"

10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)1 to 5 V ?

10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)0.6 to 5 V ?

10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)1 to 5 V ?

Next, mount part (b) to the body from the rear and insert it until (b) comes into contact with the panel for fixing.

Next, mount part (b) to the body from the rear and insert it until (b) comes into contact with the panel for fixing. Panel mount adapter (Part No.: ZS-46-B) Panel mount adapter + Front protective cover (Part No.: ZS-46-D) [F 2] Setting of OUT2 Same setting as [F 1] OUT1.

Next, mount part (b) to the body from the rear and insert it until (b) comes into contact with the panel for fixing. Panel mount adapter (Part No.: ZS-46-B) Panel mount adapter + Front protective cover (Part No.: ZS-46-D) [F 2] Setting of OUT2 Same setting as [F 1] OUT1.

Next, mount part (b) to the body from the rear and insert it until (b) comes into contact with the panel for fixing. Panel mount adapter (Part No.: ZS-46-B) Panel mount adapter + Front protective cover (Part No.: ZS-46-D) Hysteresis "Nil" or M kPa ZSE20(F) : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter), Option 3: T (w/o Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A2 (Bracket B, Horizontal Mounting)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: B (Panel Mount Adapter)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A2 (Bracket B, Horizontal Mounting)