, D-C8 A 8.5 D-H7, D-H7W, D-H7F 8.5 A Hs B Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting Minimum strokes are as follows based on the space required for mounting auto switches.
CDRBU2W10-D CDRBU2W15, 20, 30-D (Figures below show size 20 actuators.) 2 x M3 x 0.5 through 2 x 3.5 through 2 x 3.5 through 17 2 x S2 2 x S1 10.5 B port A port 0.5 9 2 x S1 2 x S1 3 2 x M5 x 0.8 (Connection port) 10.5 2 x 3.5 through A port B port 2 x R D-90 ,D-S99 D-90A ,D-T99 3 D-97 D-93A (3m) 0.5m 18.5 2 2 15 20.5 CDRBU2W15-D (Approx. 26.5 for connector type) CDRBU2W20/30-D 1.
D-C80C D-H7 D-H7W D-H7BAL D-H7NF D-A73C D-A80C D-H7C D-A79W D-F7 D-F7W D-J79 D-J79W D-F7BAL D-F79F D-J79C Auto Switch Mounting Position (mm) D-A7H/A80H/A72 D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C/F7BAL D-F79F D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-A73 D-A80 D-A79W Bore B A B A B A B A B A 32 8 (6) 7 (5) 8.5 (6.5) 14.5 (11.5) 9 (7) 8 (6) 7 (5) 6 (4) 6 (5) 12 (9) 40 10 (
D-H7NF D-C7 D-C80 D-C73C D-C80C D-A73 D-A80 D-A79W Bore B A B A B A B A B A 32 8 (6) 7 (5) 8.5 (6.5) 14.5 (11.5) 9 (7) 8 (6) 7 (5) 6 (4) 6 (5) 12 (9) 40 10 (11) 12 (9) 7.5 (5.5) 12.5 (9.5) 15 (12) 13 (10) 13 (10) 11 (8) 5 (3) 11 (7) Aim at this number ( ) For air cushion type Auto Switch Mounting Height (mm) D-F7/J79 D-F7W D-J79W D-F7BAL D-F79F D-C7/C80 D-H7 D-H7W D-H7BAL D-H7NF D-A7 D-A80
D-side How to order applicable valves VQC 4 0 5 E B 0 Y 1 Series VQC4000 F E D A C B Stations are numbered in ascending order from the D-side.
connector: D-sub connector (25P) (Conforming to MIL-C-24308) e d i s U e d i s D Stations 1 2 3 4 5 6 7 8 n 10 One-touch fitting [3(R), 1(P) port] Applicable tubing O.D.: 10 For top ported R 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 39.4 (58.1) 62.1 41.7 25.7 20.9 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B P 1 P=17.5 63.3 44.5 7.5 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4 : 6 : 8 L n Formula
Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.
Side 4(A), 2(B) D side 1 16 VS4 16 stations Max. 16 stations.
Auto Switches/Proper Mounting Position for Stroke End Detection B A (mm) Dimension A Dimension B Auto switch model D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-F7W/J79W D-F7WV D-F7LF Note 2) D-F7W/J79W D-F7WV D-F7LF Note 2) D-A73/A80 D-A73/A80 D-F7NTL D-F7NTL D-F79F D-F7BAL D-F79F D-F7BAL Bore size (mm) 6 23 23.5 45 44.5 27.5 40.5
A1 B 150 0400 N 0200 R XC10 CA2 Auto switch Stroke B Dual operation Double rod Mounting Bore size CS1 Stroke A C76 Cushion Both ends N W/o cushions H Head end R Rod end Dimensions C85 C95 CP95 P + stroke A 4-EE (NPTF) P + stroke B 4-DD NCM D across flats D across flats NCA D-X Stroke A Stroke B SN + Stroke (A + B) 4-NT Depth ND 20LD + Stroke (A + B) Data ZZ + Stroke (A + B) Bore size (in
A1 B 150 0400 N 0200 R XC10 CA2 Auto switch Stroke B Dual operation Double rod Mounting Bore size CS1 Stroke A C76 Cushion Both ends N W/o cushions H Head end R Rod end Dimensions C85 C95 CP95 P + stroke A 4-EE (NPTF) P + stroke B 4-DD NCM D across flats D across flats NCA D-X Stroke A Stroke B SN + Stroke (A + B) 4-NT Depth ND 20LD + Stroke (A + B) Data ZZ + Stroke (A + B) Bore size (in
cable O.D. 6.8 to 9.6) Hs Hs 49 Ht Ht 56 34 36 A B B 33 A D-A3C D-G39C/K39C D-G5/K59 D-G5W/K59W D-G5BA D-G59F/G5NT G 1/2 (Applicable cable O.D. 6.8 to 9.6) B A HW 49 Hs Hs 24.5 B A 33 36 D-F5/J59 D-F5NT D-F5W/J59W D-F5BA/F59F D-A44 G 1/2 (Applicable cable O.D. 6.8 to 11.5) Hs Hs 31.5 Ht Ht 56 A 36 B B 30 A D-A44C G 1/2 (Applicable cable O.D. 6.8 to 11.5) B A HW 49.5 Hs 36 692 Auto Switch
(b)(SW1) 164( (3)(c)) (SW1) 8 7 6 9 A 5 B 4 C 3 D 2 1 0 F E (c) 0 1 0 17 1 2 1 18 2 3 2 19 3 4 3 20 4 5 4 21 5 6 5 22 6 7 6 23 ON ON 7 8 7 24 8 9 8 25 1 2 3 4 1 2 3 4 9 10 9 26 A 11 A 27 B 12 B 28 C 13 C 29 D 14 D 30 E 15 E 31 F 16 F 32 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D
. 10-12-25 25 Series CE1 Proper Auto Switch Mounting Position (Detection at stroke end) Auto switch A B Proper Auto Switch Mounting Position D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL D-F7BAVL/F79F Auto switch model D-A79W D-F7NTL D-A7 D-A80 D-M9 D-M9V D-F9W D-F9WV D-A9 D-A9V D-F9BAL Bore size (mm) A B A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5
, D-C8 A 8.5 D-H7, D-H7W, D-H7F 8.5 A Hs B Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting (mm) 1in = 25.4mm Minimum strokes are as follows based on the space required for mounting auto switches
phase J B C D A A COM COM COM B 12 VDC GND F.G.
, D-F5W D-J5, D-J59W D-F59F, D-F5BAL D-Z7, D-Y59, D-Y7BAL D-Z80, D-Y69, D-Y7W(V) D-Y7P(V) D-A5 D-A6 D-A59W D-F5NTL D-A3, D-G39 D-A44, D-K39 D-P5DWL Bore size (mm) MB A B A B A B A B A B A B A B MB1 32 0 10.5 1.5 14 9.5 22 4.5 17 2 14.5 0 10.5 1 13.5 40 0 21.5 1.5 25 9.5 33 4.5 28 2 25.5 0 21.5 1 24.5 CA2 50 0 23 2 26.5 10 34.5 5 29.5 2.5 27 0 23 1.5 26 63 0 28 2 31.5 10 39.5 5 34.5 2.5 32
B A C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.
D-C7 Proper auto switch mounting position (Detection at stroke end) D-H7A1/H7B Auto switch 8.5 Auto switch 8.5 16 16 approx. Hs approx. Hs A 29 B A 26 B (mm) D-C73 A D-H7A1/H7B B Hs A B Bore size Hs 7 6 22.5 6 5 22.5 7 6 25 6 5 25 8 7 28.5 7 6 28.5 14 12 32.5 13 11 32.5 20 25 32 40 Note) The above values should be used as a guide for detection at stroke end.