SMC Corporation of America
Elite Part Number Search
Search Results "ZXP7A-ZP20BS-X1E-KA"

3 7-8-10 11 Plate Cylinder Double Acting, Double Rod Series MUW Basic Style: MUWB Rod end male thread MUW40/50/63 CUJ CU CQS MUW25/32 Cylinder port CQM CQ2 RQ MU 4-ND through NS + Stroke Width across flats B1 Width across flats KA DBottom hole diameter NE 8-NC counterbore -X Width across flats KA 20Data H + Stroke S + Stroke Rod End Female Thread ZZ + 2 stroke KA H + Stroke ZZ + 2 x Stroke

Connection thread 15-3-22 4 Antistatic One-touch Fittings Series KA Branch Y: KAU H (width across flats) Soft nylon Effective area (mm 2) Connection thread M thread Uni thread Applicable tubing O.D.

DBottom hole diameter NE 8-NC counterbore -X Width across flats KA 20Data H + Stroke S + Stroke Rod End Female Thread ZZ + 2 stroke KA H + Stroke ZZ + 2 x Stroke Dimensions except mentioned above are the same as male thread type.

KA Rubber material is not used.

Wiper ring Piston seal Valve seal Tube gasket Holder gasket Rod seal 125 CS1H125A-PS SDR-36 P7 C120 G55 RPS-125 SKY-36 140 CS1H140A-PS SDR-36 P7 C135 G55 RPS-140 SKY-36 160 CS1H160A-PS SDR-40 P7 C155 G55 RPS-160 SKY-40 1.10-6 Series CS1 Basic/CS1B Lube (CS1B), Non-lube (CS1BN), Air-hydro (CS1BH) With auto switch/CDS1B (mm) Stroke range (mm) Bore (mm) Style M KA K MM EA C D E B A AL J G FA

KB KR Fixed end KA KQG2 At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%. KG KFG2 Max.

Standard without auto switch: 12 and 16; 5 stroke, 25; 5 to 10 stroke Built-in magnet with auto switch: 20; 5 stroke 6 Series CQM Dimensions 32 to 50 2-HA through Auto switch 2-P 2-HB through V KA F Q U 2 x 2-OB counterbore with depth RB 2-N through IB IA EA EB EC M 22 Z 11 Min. lead wire bending radius 10 (KB) D-A7/A8 Auto switch KA A + Stroke B + Stroke W L S EA EB EC M J 2 x 2-OA 2 x 2

-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (KB) D-A7/A8 Auto switch KA A + Stroke B + Stroke W L S EA EB EC M J 2 x 2-OA 2 x 2-RA Both ends tapped style (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com I CX D D-X 202 x 4J E MB Data MC KA MA C NA K NB S + Stroke H B ZZ + Stroke The allowable angle difference of E to B should be limited to 1.5.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com I CX D D-X 202 x 4J E MB Data MC KA MA C NA K NB S + Stroke H B ZZ + Stroke The allowable angle difference of E to B should be limited to 1.5.

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, CONNECTORS, KA FITTING FOR ANTI STATIC, FX, KA 6MM, .01895 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, CONNECTORS, KA FITTING FOR ANTI STATIC, JD, KA 10MM, .03176 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, CJ, KA 4MM, .02204 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, FJ, KA 6MM, .02089 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, UNION ELBOW, CONNECTORS, KA FITTING FOR ANTI STATIC, AX, KA 3.2MM, .01100 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, UNION ELBOW, CONNECTORS, KA FITTING FOR ANTI STATIC, AJ, KA 3.2MM, .01470 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, AJ, KA 3.2MM, .01760 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, FH, KA 6MM, .02204 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, FH, KA 6MM, .05566 lb

Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, CONNECTORS, KA FITTING FOR ANTI STATIC, HH, KA 8MM, .06982 lb