SMC Corporation of America
Elite Part Number Search
Search Results "AC50B-N10CE-T-2Z-B"

Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102 psi (0.7 MPa). 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4.

(extension) A B Air pressure supplied from B operates on surface 3. (retraction) A B Mounting accuracy improved Positioning holes are provided on the work piece mounting surface for easy alignment.

Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.

Controlled flow 0.25 0.3 0.3 0.25 0.25 0.25 0.25 * C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed.

Note 1) 20 16 17 Elbow for piping port/IZN10D B C 180 10 (mm) B Model C 16 D 11.5 IZN10-16 (mm) IZN10-17 (inch) 22 24.5 18.5 12 Female threads for piping (Rc1/8)/IZN10-11 16 Rc1/8 13 Width across flats 14 456 Ionizer IZN10 Series Dimensions L-bracket/IZN10-B1 IZS (Mounting angle adjustable range) 40 7.5 17 IZN IZN 2 x R10 3.4 2 x M3 2 x 3.4 IZF 25 40 5 ZVB 50 Internal mounting IZD IZE 20.5

Note 16 CJ-L016B CJ-F016B CJ-T016B 10 16 Foot bracket Flange bracket T-bracket Common for models D-C7, D-C8, and D-H7 BJ2-010 BJ2-016 Caution 1. For Series CJ2X, up to 0.1Nl/min (ANR) of internal leakage is anticipated due to cylinder structure. T-bracket is applicable to double clevis type (D). 2

Time t (ms) t (ms) (Averaging) (Averaging) Switch output operation when normal ON [Selectable response times: t] 2.5ms (normal), 24ms, 192ms or 768ms The normal setting is selected when shipped from the factory.

E 21 SN LQ1 LQ1 fittings Nut (including insert bushing), 1 location removed Fitting type E Union elbow T Union tee Applicable tube size Metric Inch Applicable tube size (mm) Applicable tube (inch) Reducing Reducing Size No.

These parameters include Time (T), elapsed time (t), Set Repetitions (N), actual repetitions (n), Set/Reset Priority and more. 24 PneuAlpha How to Use PneuAlpha Series Controllers Getting Started Table 6.2: Function Block Description Table 6.1:Key Number and Basic Operation Others Gives more Options for a Version Check, Password Protection, Summer Time Change Schedule, Modem Initialization

Time t (ms) t (ms) (Averaging) (Averaging) Switch output ON operation [Selectable response times: t] 2.5ms (normal), 24ms, 192ms or 768ms The normal setting is selected when shipped from the factory.

0 e New PFA q Body New PFA w Sensor Super PFA e Tube PPS r Housing A PPS t Housing B PPS y Housing C POM u Bushing PPS i Cap FKM o Gasket FKM !0 O-ring Stainless steel 304 !1 Thread PVC !2 Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !

C A 1(P) 2(A) Air Supply Warning B 1 Mount air filter to supply side close to valve. Filtration rating has to be 5m or smaller. 3(R) Model VHS2500 VHS3500 VHS4500 VHS5500 A 60 78 85 136 B 20 29 32 56 C 12.8 12.8 12.6 32 D 40 53 70 90 E 44 53 64 80 F 33 42 49 65 G 28 29 36 54 H 7.5 7.5 10 10 3.6-18

Related Products/Tubing: Nylon, Soft Nylon, Polyurethane How to Order Tubing Use the kind of tubing indicated at the right for suction filter with one-touch fitting (Series ZFC). 0604 20 B T Refer to Best Pneumatics No. 6 for details on valves.

Model Selection 1 Obtain the correction factor for the temperature from data A or B and the correction factor for the air pressure from data C. Temperature Data A or B = Series IDUS: Data A Series IDFS: Data B Air pressure Data C = 3 2 Calculate corrected air flow by using A or B and C.

Note) Depths of mark Q1, Q2 indicate that the body(A)/(B) are penetrated respectively.

Temperature Data A or B = Series IDUS: Data A Series IDFS: Data B Air pressure Data C = 2 Calculate corrected air flow by using A or B and C. Corrected air flow = (Air flow) (Data A x Data C) Corrected air flow = (Air flow) (Data B x Data C) 3 Select a model having an air flow capacity that is higher than the corrected air flow.

Work 1 Work 2 Work n Atmosphere A = Maximum pressure value B = Minimum pressure value P-1 = A (A B) / 4 H-1 = (A B) / 2 For compound pressure PSE533 PSE543 PSE563 For low differential pressure For low pressure For vacuum For positive pressure Pressure range C Display calibration function This function eliminates slight differences in the output values and allows uniformity in the numbers

How to Order VXA32 VXA31 4 Bracket Nil B None With bracket Stainless steel body model is supplied with bracket. VC Model VDW VQ Thread type Nil T F N Orifice size Rc NPTF G NPT 1 2 3 4 1.5 mm 2.2 mm 3 mm 4 mm VX2 VX Refer to the table (1) given below for availability.

(Example) Body class 3 A side: 10 x 8 B side: 8 x 6 Order as shown below. A SMC LVN30 S 10 08 B Different dia. tubing size (B side) Applicable tubing size (A side) 938 High Purity Fluoropolymer Needle Valve LVN Series Standard Specifications Model LVN20 LVN30 LVN40 4, 6 Tubing O.D.

Operating pressure (MPa) Flow Characteristics/Weight Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Weight (kg) Port size Pilot port size (Nominal size) Function Valve model C [dm3/(sbar)] 7.5 8.4 7.1 7.9 6.8 7.2 6.5 6.9 7.6 (2.4) 9.3 (2.4) C [dm3/(sbar)] 7.5 8.7 7.4 8.6 6.3 6.5 7.9 (3.4) 9.5 (3.4) 6.1 6.5 b 0.34 0.38 0.40 0.37 0.38 0.40 0.41 (0.47) 0.39 (0.46) 0.36 0.41 b Cv