Series: 3 (VQZ3000), Composite Symbol: 2 (2 Position Double), Seal Type: 0 (Metal Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: Y (DIN Connector w/o Light, w/o Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 03 (Base Mounted w/Sub-plate Rc3/8), Q: Q (CE Marked)
Series: 3 (VQZ3000), Composite Symbol: 2 (2 Position Double), Seal Type: 0 (Metal Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 03 (Base Mounted w/Sub-plate Rc3/8)
Series: 3 (VQZ3000), Composite Symbol: 2 (2 Position Double), Seal Type: 0 (Metal Seal), Function: BR (High Speed Response 0.9W - DC Only, External Pilot), Coil Voltage: 5 (24VDC), Lead Wire: YZ (DIN Terminal w/Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 03 (Base Mounted w/Sub-plate Rc3/8)
Series: 3 (VQZ3000), Composite Symbol: 2 (2 Position Double), Seal Type: 0 (Metal Seal), Function: B (High Speed Response 0.9W - DC Only), Coil Voltage: 5 (24VDC), Lead Wire: Y (DIN Connector w/o Light, w/o Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 03 (Base Mounted w/Sub-plate Rc3/8)
Series: 3 (VQZ3000), Composite Symbol: 2 (2 Position Double), Seal Type: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 03 (Base Mounted w/Sub-plate Rc3/8)
Function: 2 (2 Position Double Pilot), Body Size: 5 (3/4 Standard), Piping: 0 (Side Ported), Port Size: 03 (3/8, 10A)
Function: 2 (2 Position Double Pilot), Body Size: 5 (3/4 Standard), Piping: 0 (Side Ported), Port Size: 03 (3/8, 10A), Thread: N (NPT)
Function: 2 (2 Position Double Pilot), Body Size: 5 (3/4 Standard), Piping: 0 (Side Ported), Port Size: 03 (3/8, 10A), Thread: T (NPTF)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Made to Order: X128 (Analog 4 to 20mA 2 Output Type)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Calibration Certificate: None, Made to Order: X128 (Analog 4 to 20mA 2 Output Type)
: None, Made to Order: X128 (Analog 4 to 20mA 2 Output Type)
Certificate: None, Made to Order: X128 (Analog 4 to 20mA 2 Output Type)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
), Calibration Certificate: None, Made to Order: X128 (Analog 4 to 20mA 2 Output Type)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Certificate: A (Calibration Certificate), Made to Order: X128 (Analog 4 to 20mA 2 Output Type)