Separate switch spacers (BMG2-012) are required to retrofit auto switches (M9 type) on cylinders 25 to 63. 2 1 m type lead wire is only applicable to D-A93. Refer to page 1360 for details on other applicable auto switches than listed above. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649. Auto switches are shipped together (not assembled).
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: Built-in, Lock Unit Switch Type: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M
Applicable models: D-A73, A73H, A73C, R73, D-97, 93A, A93, A93V, D-A53, A54. MHZ2 rMount a switch at the center of the operating range. MHZJ2 Adjust the mounting position of an auto switch so that the piston stops at the center of the operating range (the range in which a switch is ON.)
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com