"n" pcs. Nil S n 12mm 16mm 20mm 25mm 2 pcs. 1 pc. "n" pcs.
Nil With power supply cable (3 m) IZN10E-CP Z With power supply cable (10 m) IZN10E-CPZ N Without power supply cable * Mounting is interchangeable with the current model (IZN10).
For valves which had an “E” prefix, the thread type now needs to be indicated in the part number (e.g., symbol “F” for G thread).
Valve part number example: EVT307-5DO-01-Q→VT307-5DO-01F-Q
Example of valve series with an “N” prefix: NVT3, NVO3, NVK, NVP, NVF, NVS, NVN, NVY, etc.
Note) One of Nil, N, F or T is entered as a thread symbol. 14
Piping and Operation Caution Mounting posture of the pump is set with the mounting foot facing downward. Air to be supplied to the air supply port
F Main power switch L Power supply cable (Accessory, with Ferrite core) Each presses of the [MODE] key changes the operating mode as follows.
A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV
Template DKP50047-F-085D Avoid repeating sudden charges and discharges of the air tank. These may cause the temperature of the product the exceed the maximum allowable value. Danger Do not exceed any of the specifications listed on the label, in section 2 of this document or on the customer drawing. Air equipment has air leakage as standard within certain limits.
Move Speed Position Accel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn mm/s2 mm/s mm mm/s2 mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 6.
When selecting "No (N)", the controller will start without uploading. The title window shown below will be displayed. When the PC is not able to communicate with the controller, the following screen is displayed. When select OK, the title window will be displayed. -12No. JXC-OMT0002-C After the initial title window is displayed, the following main window will be displayed.
(f) Input the step data No. 2 (INx). (g) Turn the "DRIVE" input ON. Step data No. 2 (OUTx output) will be output. (h) The AREA output will turn OFF. The BUSY output will turn ON and INP output will turn OFF. (The positioning operation will start). (i) The AREA output for step data No.2 will turnON (at 170mm from the origin point).
ARX21 mm Nil F Thread type G Pressure gauge Rc(PT) NPT G(PF) Nil N F ARX20Nmm ARX21Nmm P Port size Panel nut 1/8 1/4 01 02 Option combination numbers Panel nut is also included with B.
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Regulator for 2 MPa Series ARX20 How to Order ARX2 0 01 Regulator for 2 MPa Option None Nil Regulating pressure range 1348112 G361001 G461002 G36401 G46402 G36P10N01 G46P10N02 G36P4N01 G46P4N02 1348110A B Bracket ARX20 Nil F 0.05 to 0.85 MPa 0.05 to 0.30 MPa 0 1 ARX21 Nil F Note 1) (2) Thread type G Pressure gauge ARX20N Rc NPT G Nil N F ARX21N P Port size Panel nut 1/8 1/4 01 02 Option
Pin Cylinder: Double Acting, Single Rod Series CJP2 4, 6, 10, 16 CJ1 How to Order CJP CJP2 10 F 15 D Standard CJ2 CDJP2 F 10 15 D M9BW S CM2 Built-in magnet CG1 Made to Order (Refer to page 24.) With auto switch (Built-in magnet) MB Mounting MB1 Mounting Standard Built-in magnet Symbol Number of auto switches 2 pcs. 1 pc.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature
: °F), Bracket: None, Calibration Certificate: None
: °F), Bracket: None, Calibration Certificate: None
AV 12 VDC (Max. 300 mA) with accuracy of 12 to 14.4 VDC Note 2) AU Power supply output 24 VDC (Max. 300 mA) with accuracy of 22.0 to 26.8 VDC q0 to 10 VDC (Output resistance: 6.5 k or more with accuracy of 0.5%F .S. or less) w4 to 20 mA (Output resistance: 800 or less with accuracy of 0.5%F .S. or less) Output: 4 points AF Command output AR Courtesy of Steven Engineering, Inc.-230 Ryan Way
IC Electroless nickel plated Dimensions VBA Caution A Model ARJ1020F-M5-04 B 10.4 C 4 D E F G H J K 21 VE 10.6 (Width across flats: 10) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.
.S. or less (Temperatue conditions: at 25C) Display accuracy 1% F .S. or less (Temperatue conditions: at 25C) Repeatability 3% F .S. or less (0 to 50C with 25C standard) Temperature characteristics Piping port M5 x 0.8 0 to 50C (With no condensation) Ambient operating temperature Ambient operating humidity 35 to 85% RH (With no condensation) Shock resistance 980 m/s2 X, Y, Z directions, 3