T O O R D E R NZM V A C U U M E J E C T O R D I M E N S I O N S W I T H VA LV E A N D VA C U U M S W I T C H W I T H V A LV E S A N D S W I T C H (N)ZM HK5LZ V O LTA G E 5 24VDC 6 12VDC N O Z Z L E D I A M E T E R 05 0.5mm 07 0.7mm 10 1.0mm 13 1.3mm V A C U U M S W I T C H Nil Without E15L Solid State (NPN) E55L Solid State (PNP) M21L Reed M15L Non-Contact S Y S T E M C I R C U I T Supply
Mounting Positions and Height for Stroke End Detection Reed switch Solid state switch D-A9 A B W D-M9 D-F9BAL D-F9 W 12 A B W 16, 20, 25 W A B 32, 40, 50 (mm) D-A9 D-M9 D-F9 W Auto switch model D-F9BAL Mounting height Hs exists only for the D-F9BAL type.
PF2W740 PF2W711 Model Measured fluid Flow rate measurement range Set flow rate range Rated flow range Minimum set unit Water 1.7 to 17.0 l/min 0.35 to 4.5 l/min 3.5 to 45 l/min 7 to 110 l/min 1.7 to 17.0 l/min 0.35 to 4.5 l/min 3.5 to 45 l/min 7 to 110 l/min 2 to 16 l/min 0.5 to 4 l/min 5 to 40 l/min 10 to 100 l/min 0.1 l/min 0.05 l/min 0.5 l/min 1 l/min 0.1 l/pulse 0.05 l/pulse 0.5 l/pulse
N.O. q IFW50--75/76 e Color of lead wire Black Symbol Contact q w Power supply (Common) w Red Terminal (Relay terminal) 24 VDC Gray e Power supply (Light terminal) N.O. N.C. q IFW50--85/86 e Color of lead wire Black Symbol Contact q w Power supply (Common) White Terminal (Relay terminal) w 24 VDC Gray e Power supply (Light terminal) N.C. N.O.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.
(g) Note 3) W = 65.4n + m + 128.2 W = 13n + m + 36 W = 41.2n + m + 77.6 (n: Number of SUP/EXH blocks, m: DIN rail weight) Note 1) In cases such as when many valves are operated simultaneously, supply pressure to port P on both sides and exhaust from port R on both sides, using "stations B (SUP/EXH block both sides)".
IZTP43(-L) and IZTN43 (2pcs.), IZTP41(-L) and IZTB40 (2pcs.) Separate connection Example of connecting IZTC41(-L), IZTP43(-L) andIZTN43 Example of connecting IZTC41(-L), IZTP43(-L) and IZTN43 (4pcs.) Example of connecting IZTC41(-L), IZTP43(-L) and IZTN43 (2pcs.) , IZTP41(-L) and IZTB40 (2pcs.) 1-2.
200 200 P = 0.5 MPa m MGTL63 P = 0.5 MPa 100 MGTM63 100 Load mass m (kg) Load mass m (kg) Larger than 100st Larger than 50st 50 40 50st or smaller 75, 100st 30 20 50 25, 50st 40 10 l 30 5 4 3 m 20 2 10 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 30 40 50 100 200 300 400 Eccentric distance l (mm) Eccentric distance l (mm) 300 300 200 MGTL80 P = 0.5 MPa 200 MGTM80 P = 0.5 MPa 100 Load mass
Rc C3SF-6J-A G C3SFF-6J-A Rc G C3SF-6-A NPT C3SFN-6J(Z)-A NPT C3SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: W Piping port thread ty pe (9) Part No. Rc G NPT C3SF-W(Z)-D C3SF-W-D Appearance and part No. Semi-standard: 6W Piping port thread ty pe (9) Part No.
Rc C3SF-6J-A G C3SFF-6J-A Rc G C3SF-6-A NPT C3SFN-6J(Z)-A NPT C3SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: W Piping port thread ty pe (9) Part No. Rc G NPT C3SF-W(Z)-D C3SF-W-D Appearance and part No. Semi-standard: 6W Piping port thread ty pe (9) Part No.
pressure: 0.5 MPa 1000 25 15 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 1500 Effective area (mm2) Effective area (mm2) 20 10, 12 10 08 1000 15 500 10 5 500 5 0 0 0 0 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) 2 Stainless Steel Speed Controller Series ASG Construction Elbow type Meter-out Meter-in y y u u q w e r t q w e r t i i o o !
Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.
, D-A90 Basic, Foot, Double acting Single rod 25 to 300 CG3 25 to 63 Flange, Clevis 80, 100 D-G5(W), D-K59(W), D-B64 For the trunnion type, please contact SMC sales representatives. 364 Air Cylinder Short Type Standard: Double Acting, Single Rod CG3 Series 20, 25, 32, 40, 50, 63, 80, 100 RoHS CJ1 How to Order CJP CJ2 L 25 CG3 100 N JCM CDG3 L 100 M9BW N 25 C With auto switch CM2 With auto
Above 2.95" Stroke o Series NCM C onstructio n I Part s L i st o Parts List White alumite White alumite ctr a."t"H"rd Ch.." Pfrt"d Series NCM Front Nose Mutntinu: NCMB (inch) bola(hrah) lrd\4 lri( 4 g D K N Ilc NE NN w ZB o75 l%l 0.250 y4-28 0.50 o.624 0.86 0.75 0.62 o.12 %4a 0.50 0.95 2.97 tesd [-?
28 50% of max. rated flow [ 2.00] 2.00 L/min (4 L type) [ 8.0] 8.0 L/min (16 L type) [ 20.0] 20.0 L/min (40 L type) [ 50] 50 L/min (100 L type) [ 126] 126 L/min (250 L type) [ P_1] Set value (OUT1) [F 1]/[ oUt1] Page 29 5% of max. rated flow [ 0.20] 0.20 L/min (4 L type) [ 0.8] 0.8 L/min (16 L type) [ 2.0] 2.0 L/min (40 L type) [ 5] 5 L/min (100 L type) [ 12] 12 L/min (250 L type) [ H_1]
L [mm] Eccentric distance L [mm] MGPKL32 50 mm stroke or less, V = 400 mm/s Over 50 mm stroke, V = 400 mm/s 30 30 10 10 Load mass m [kg] Load mass m [kg] 1 0.1 1 10 100 100 10 Eccentric distance L [mm] Eccentric distance L [mm] 16 MGPK Series L L Plate Material Carbon Steel /MGPKL Horizontal Mounting m m MGPKL16 L = 50 mm, V = 200 mm/s or less L = 100 mm, V = 200 mm/s or less 10 10 Load
If W-AREA1 >W-AREA2, the "Parameter ALM" alarm will be Basic parameter "Stroke (-)" W-AREA1 W-AREA1 "Stroke (+)" Basic parameter "Stroke (-)" W-AREA2 W-AREA2 activated. However if W-AREA1= W-AREA2 = 0, WAREA will be OFF and no alarm will be generated.
Rubber seal IP65 Option (Y, YZ only) W Standard IP65 rated Manual override B Non-locking push type (Tool type) Slotted locking type (Tool type) Electrical entry Light and surge voltage suppressor Electrical entry Symbol Grommet (DC specification) Without G L LO M MO Y YO YZ YOS L type plug connector with lead wire L type plug terminal without connector Function Standard type (1.0W) High