Electrical wiring 10 8. Maintenance 11 9. Mounting accessories (option) 12 10.
ZL-OM00801 Circuit Diagram ZL112 ZL112-K1*-D*** A ZL112-K2*-D*** A ZL212 22 - Doc. no. ZL-OM00801 Weight 23 - Doc. no. ZL-OM00801 Exhaust Characteristics and Flow Characteristics of Ejector 24 - Doc. no.
MHZ2-6 MHZJ2-6 MHZA2-6 MHAJ2-6 Cylinder inside diameter (mm) 6 Fluid Air Double acting: D 0.15 to 0.7 Operating pressure (Mpa) Normally open: S 0.3 to 0.7 Normally closed: C Single acting Ambient and fluid temperature (oC) 10 to 60 Repeatability (mm) +/-0.01 Maximum operating frequency (c.p.m.) 180 Lubrication Lubrication not required. Action Double acting, single acting O.D.
Symbol Double acting How to Order D 20 MHC2 Y59A S Number of auto switches Single acting Angular style air gripper 2 1 S Bore size 10mm 10 Action Double acting D Single acting S 16mm 16 20mm 20 25mm 25 Caution Be sure to read before handling.
D Blue (BU) Fixed end MS Translucent (N) LQ Fluid Air MQR Burst Pressure Characteristics Curve and Operating Pressure Max operating pressure (at 20C) 0.8 MPa T One-touch fittings Applicable fittings 10 18 24 30 36 Min. bending radius (mm) 5 Refer to the burst pressure characteristics curve.
6.15 The Schmitt Trigger .6-10 6.16 The Hour Meter .6-11 7.
Description Material Aluminum casted Aluminum casted Top cover Bottom cover q w VOA301-M V0307E-D-X56 3 port switching valve (for operation control) e 1 VR4152-00-0 GA46-10-01 12702A 12705A NLP-100A PNY-25 SW-100 x 6 x 2 JIS B 2401P3 r t y u i o !0 !
-X 389 MK Series Specifications 12 16 20 25 32 40 50 63 Bore size (mm) Double acting 90 10 Clockwise, Counterclockwise Action Rotary angle Note 1) Rotary direction Note 2) Rotary stroke (mm) Clamp stroke (mm) Theoretical clamp force (N) Note 3) 7.5 9.5 15 19 10, 20, 30 10, 20, 30, 50 40 75 100 185 300 525 825 1400 Air 1.5 MPa Fluid Proof pressure Note 4) 0.1 to 0.6 MPa Operating pressure
L1 L2 A (2) L3 H (1) T2 T1 D1 D2 Model ASR ASQ AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS120-M5 M5 x 0.8 M5 x 0.8 8 10 28.3 10.3 9 9 25 22.2 25.5 AS120-U10/32 10-32UNF 10-32UNF AS220-01 30.5 13.2 14.3 14.6 32.4 27.4 12 (12.7) 18 35.5 1/8 1/8 AS220-02 35.3 17.5 18 19.5 34.8 29.8 17 (17.5) 27.2 40.3 1/4 1/4 AS320-03 40.8 19.7 22.5 24.3 40.6 35.6 19 30 45.8 3/8 3/8 AS420
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2001 SMC CORPORATION All Rights Reserved 1st printing October, 2001 D-SMC.L.A. P-80 (D) All specifications in this catalog are subject to change without notice. Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.
For the D-P3DW;, refer to the catalog CAT.ES20-201. The D-A9;/M9;;;/P3DW; auto switches are shipped together, (but not assembled).
Rod end thread Male thread Female thread Long male rod end Nil F G Cushion CG1 Mounting Auto switch mounting bracket Note) N Rubber bumper B L F G D Basic Foot Rod flange Head flange Clevis Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.)
Plate Cylinder: Double Acting, Single Rod 25, 32, 40, 50, 63 Series MU How to Order B 25 D 30 M Z MU B 25 D 30 Z M S M9BW MDU With auto switch With auto switch (Built-in magnet) Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. Mounting B L F G C D Basic Foot Rod flange Head flange Single clevis Double clevis Auto switch Nil Refer to the below table for applicable auto switch models.
PAB-OM-H007-D PRODUCT NAME Process Pump MODEL / Series / Product Number PAF3410 Contents Safety Instructions P.2 to 3 1. Precautions for handling P.4 2. Precautions for installation -P.5 3. Description and function of individual port -P.5 4. How to use -P.5 to 6 5. Maintenance and check -P.6 6. Specification and how to order P.7 to 8 7. Discharge capability -P.9 to 10 8.
Vale specifications Model XLA-16 XLA-25 XLA-40 XLA-50 XLA-63 XLA-80 XLA-100 XLA-160 Flange (valve) size 16 25 40 50 63 80 100 160 Actuating type Normally closed Fluid Vacuum of inert gas Operating temperature oC 5 to 60 (5 to 150 for high temperature type) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 1 5 14 45 80 160 200 300 800 Internal 1.3 x 10-10 for
If a product is required independently, please order using the product numbers above. 10 Doc. no.IZ*-OMX0012-B Cleaning kit IZS30-M2 IZS30-A0201 IZS30-A0202 1 10 1 Provided together with 1 felt pad grindstone, 1 rubber grindstone, and 2 replacement felt pads Provided together with 10 replacement felt pads Provided together with 1 replacement rubber grindstone 2 2. How to Use 2-1.
Refer to page 8 to 10, and consider the distance to the hard stop as the arm length. Please note that the graph should only be used as a guide as there is a tolerance of about 10% in the clamp cylinder body. D) In the state of C), adjust shim so that the arm side block contacts the workpiece.
Grease pack part no.: GR-S-010 (10 g) 63
Cylinder Hexagon socket head cap screw (4-M8 x L20) Cylinder flange Joint1 Strut (4-M10 x L22) Mounting bracket2 IN OUT Note) 1, 2: Jointed part Hexagon socket head cap screws (2-M4 x L6) Protection cover IN DRAIN Fig. 1 Fig. 2 Mounting bracket set screw Cover assembly Cover assembly Element assembly Guide assembly Screw (M3) Element FN111-10 FN112-10 FN111-10 FN112-10 Fig. 4 Fig. 3 484 Series
Grease pack part no.: GR-S-010 (10 g) 63