Centralized wiring type IISA2S-1 IISA2S-2 IISA2S-3 IISA2S-4 IISA2S-5 IISA2S-6 Individual wiring type IISA2P-1 IISA2P-2 IISA2P-3 IISA2P-4 IISA2P-5 IISA2P-6 ISA-5-1 ISA-5-2 ISA-5-3 ISA-5-4 ISA-5-5 ISA-5-6 ISA-5-7 73.0 135.5 173.0 210.5 248.0 285.5 323.0 5.5 35 35 Pressure Gauge for Air Catch Sensor Round pressure gauge Square embedded pressure gauge Connection thread GC3 4 4 AS G36 01 Nil
55.8 8.5 (6.3) 8 5 22 M5, 1/8 6 36 (27.6) 1 (IN) port M5, 1/8 2 (N.C.) port 1/8, 1/4 1/8, 1/4 2 (N.C.) port 1 (IN) port 2 x M3 x 5 2 x M4 x 6 15 12.8 Bracket assembly part no.
(P) (B) 2 (A) 4 3 position exhaust center (A) 4 (B) 2 5 (R1) 3 (R2) 1 (P) 3 position pressure center (A) 4 (B) 2 i 5 (R1) 1 (P) 3 (R2) 5 (R1) 3 (R2) 1 (P) (This figure shows a closed center type.)
[C] Correction factor 5 to 30 1.41 35 1.21 40 1 45 0.92 50 0.75 55 0.63 60 0.53 Inlet air temp. [C] Correction factor 5 to 45 1.15 50 1.07 55 1 60 0.95 65 0.9 70 0.86 75 0.82 80 0.79 Inlet air temp. [C] Correction factor 5 to 45 1.21 50 1.10 55 1 60 0.87 65 0.76 70 0.74 75 0.72 80 0.70 Inlet air temp. [C] Correction factor 5 to 30 1.3 35 1 40 0.82 45 0.68 50 0.57 Inlet air temp.
NBR seal) 5 to 60C Note 1)/5 to 99C Note 1) (FKM seal) VNH A VNH B 1 3 1 3 Pressure Temperature Lubrication 5 to 50C Note 1) 0.25 to 0.7 MPa Pilot air Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
Content 0 1 1 1 2 Reserved 3 1 4 1 5 Reserved 6 1 7 1 -67No.EX-OMQ0015CN Unit diagnostic status 0 7 6 5 4 3 2 1 0 Byte 2 Bit No. Content 0 10 1 11 2 12 3 13 4 14 5 15 6 16 7 17 Unit diagnostic status 1 7 6 5 4 3 2 1 0 Byte 3 Bit No.
Inch size 1/8" 1/4" 5/32" 1/8" 5/32" 1/4" 5/16" 1/8" 5/32" 1/4" 5/16" 3/8" 1/4" 5/16" 3/8" 3/8" 1/2" Free flow 0.2 0.3 0.4 0.6 0.6 0.7 1.0 1.3 1.5 1.6 1.7 2.5 4.4 4.8 C values: Sonic conductance Controlled flow 0.2 0.3 0.4 0.7 0.8 0.6 0.9 1.3 2.1 2.4 3.3 4.4 4.9 dm3/(sbar) Free flow 0.3 0.4 0.2 0.3 0.3 0.4 0.4 0.3 0.3 b values: Critical pressure ratio Controlled flow 0.2 0.2 0.3 0.3 0.3
REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 7 12 Air flow (l/min (ANR)) 38 Controlled flow CX 0.1 0.2 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C In-line Type RHC Air Flow/Effective Area MK(2) AS2001FM
1 (P) (A) 4 (B) 2 3 position exhaust center (A) 4 (B) 2 5 (R1) 3 (R2) 1 (P) 3 position pressure center (A) 4 (B) 2 i 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) (This figure shows a closed center type.)
Right side Left side Form and mounting direction of stroke adjusting unit L unit H unit Port Port Stroke adjusting unit Example of LH attachment D-X Individual -X Technical data 1107 Series MY2H/HT Construction Single axis type: MY2H w @2 t @1 !6 @9 #8 MY2H16 MY2HT16 @3 MY2H16 MY2HT16 !3 e $2 q $0 #9 !8 u i o y !0 @8 $6 !1 $1 #0 r $5 !4 @5 !9 @3 !5 #1 @4 $4 !2 $3 #3 #5 #6 @0 #4 #7 !
to 5 V) 1 1 V 1.04 V 5 V Voltage output (0 to 10 V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20
A 13/14 16/19 Rated power consumption 50/60 Hz Note 5) kW 3.4/4.4 (4.4/5.0) 4.6/6.0 (5.6/6.6) Noise level (Front 1 m/Height 1 m) Note 5) dB (A) 70 70 Waterproof specication IPX4 Accessories Alarm code list stickers 2 pcs.
to 55C (23 to 131F) Note 1) 5 to 50C (23 to 122F) (23 to 131F) Note 1) 5 to 50C 5 to 55C (23 to 131F) (23 to 131F) Note 1) 5 to 50 C 5 to 50C (23 to 122F) Outlet air atmospheric pressure dew point Inlet air flow rate l/min (ANR) (SCFM) Note 2) Standard performance 15C (-5F) 56 (2.0) 111 (3.9) 222 (7.8) 335 (11.8) 560 (19.8) 830 (29.3) 1110 (39.2) 665 (23.5) 28 (1.0) Outlet air flow rate l
EX9-AWESfor M8 EX9-AWTSfor M12 (5)Marker (1 sheet, 88 pcs.)
1 !2 !3 !4 !5 !6 !7 1 1 1 1 1 1 1 q 2B 2D e r t y u i o !
1 !2 !3 !4 !5 !6 !7 1 1 1 1 1 1 1 q 2B 2D e r t y u i o !
4 3 8 , 1 2 Port size 1 8 1 4 , 1 4 3 8 , Normally Open (N.O.)
Note 3) Port size 06 is not applicable. -9- 5. Structural Drawing, Option and Replacement Parts Structural drawing / Option / Replacement parts AF20-D AF50-D/ AF60-D AF30-D/ AF40-D (1) (1) (4) (2) (2) (3) (3) (5) (4) (5) Option Part No. No.
1 4 2 4 2 5 1 A B A B 7 7 R1 P R2 R1 P R2 6 3 position closed center/exhaust center/pressure center 3 position closed center A B 4 2 5 1 PR2 R A 3 position exhaust center A B B PR R 3 position pressure center A B 7 R1 P R2 PR R (This construction shows closed center type.)