SMC Corporation of America
Elite Part Number Search
Search Results "AS2001FM-04-J"

JOG and constant rate movement, return to origin, test drive and testing of forced output can be performed. 569 B LEC Series Teaching Box/LEC-T1 RoHS How to Order LEC T1 3 J G Enable switch (Option) Enable switch Teaching box Nil None S Equipped with enable switch Cable length [m] 3 3 Interlock switch for jog and test function Stop switch Initial language Stop switch J Japanese E English

Analog 1 to 5 V K Analog 4 to 20 mA * When using this switch in combination with an LFE0, select output specification J.

G A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB GC GD H J JC K L MM ML NN Nil TN TF 20 (16 x 2) 20, 30, 50 100, 150 38 27.5 8 7.5 3 22 12.5 7.5 11 83 11 3 11 14 M4 x 0.7 10 M4 x 0.7 25 (20 x 2) 39.5 28 10 8.5 3 26 12 7.5 11 93 13 4.5 13 17 M5 x 0.8 12.5 M5 x 0.8 32 (25 x 2) 25, 50, 100 150, 200 44.5 30 12 11.5 3 32 15 7.5 13 109 16 8 16 21 M6 x 1 15 M6 x 1 40 (32

Heat quantity by cooled substance (per unit time) Q : Unknown [W] ([J/s]) Cooled substance : Water Cooled substance mass m : (= x V) [kg] Cooled substance density : 1 [kg/L] Cooled substance total volume V : 250 [L] Cooled substance specific heat C : 4.186 x 103 [J/(kgK)] Cooled substance temperature when cooling begins T0 : 305 [K] (32 [C]) Cooled substance temperature after t hour Tt

GA AL A K 7 6 GB 4-J Width across flats B1 2-RcP H1 E D LY 4-LD LH MM Width across flats KA 18 N N S + Stroke LX Y X Y X LS + Stroke ZZ + Stroke LT B C (mm) AL Bore size Stroke range Symbol B B1 C D E GA GB H H1 J K KA MM N P LD A LS LH LT LX LY S X Y ZZ 6 40 3.2 1/4 42 Up to 1000 14 27 30 27 60 70 22 44 9 16 32 27 33 15 51 8 M8 x 1.25 13 102 193 40 156 M14 x 1.5 7 45 3.2 3/8 50 Up to 1000

CJ2-Z Series 10, 16 Air Cylinder 10-/1121-/22RoHS How to Order Cushion Clean series 10 11 Relief type Vacuum suction type Nil A Rubber bumper (Standard) Air cushion 10 D L 16 60 A R C J 2 M9BW Z B 21 D L 16 60 R C J 2 M9BW Z B Number of auto switches Nil Built-in magnet Head cover port location Nil S n 2 pcs. 1 pc. n pcs.

WH E-0.05 E-0.05 I 0 0 KA AL G port 8-J F K C-0.1 A NA F H S + Stroke ZZ + Stroke (mm) A AL Bore size Standard stroke range B1 C D E F GA GB H H1 I J K KA MM NA P RA S WA WB WH 20 20 20 W ZZ 40 30 27 Up to 300 50 35 32 Up to 300 63 35 32 Up to 300 19 27 27 6 7 7 44 55 69 139 162 162 26 32 38 14 18 18 1/8 1/4 1/4 16 20 20 8 9 9 25 30 32 87 102 102 2 2 2 25 30 30 22<19> 26<24> 26<24> 15 17

Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V

steel Special resin NBR NBR NBR NBR NBR No. 14 15 22 50 51 52 53 54 Qty. 1 1 2 2 2 2 4 2 14 Series MY2C 16, 25, 40 MY2C G Bore size Stroke Q + Stroke PG (LL) L 4-MM, depth M 4-B depth of counter bore C LA Work piece mounting center line LD through hole PA Work piece mounting center line Cylinder mounting center line PB PC MW LC LE Cylinder mounting center line QW PF NX 4 x 2-square nut J

Series AM, AMD, AMH, AMG 150 CA AM AMD AMH AMG Thread type (3) Nil Rc F G N NPT Body size Accessory (Option) A With drain cock (1) Note 3) Corresponds to attachment symbols C, D, and J. Select according to the type of threads used on the body. C With N.O. auto-drain D With drain guide (2) 150 250 350 450 550 650 850 With N.C. auto-drain J Note 1) 850 size comes with a ball valve.

5 @2 %0 %1 %2 %3 %4 8-13-17 18 Series MY2 16, 25, 40 MY2C G Bore size Stroke Q + Stroke PG (LL) L 4-MM, depth M 4-B depth of counter bore C LA Workpiece mounting center line LD through hole PA Workpiece mounting center line Cylinder mounting center line PB PC MW LC LE Cylinder mounting center line QW PF NX 4 x 2-square nut J PD LB NH NT NW PE PE LW NV Courtesy of Steven Engineering, Inc.-

Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Communication example When reading the product number and serial number Unit identifier 1 Function code 04 Read 19 consecutive data from register 005h.

FGDTF*-04 FGD-CV005-06 FGDTF*-06 (5) FGD-CV006-03 FGDCE*-03 FGD-CV006-04 FGDCE*-04 FGD-CV006-06 FGDCE*-06 FGD-OP001 FGD*B (10) KT-FGDC FGDC KT-FGDE FGDE (2)(4)(6)(13)(16) KT-FGDT FGDT KT-FGDF FGDF FGD-CA002 FGDT,F(L250) (7)(9)(11)(12)(13) (14)(15)(16)(17) FGD-CA003 FGDT,F(L500) L500 (18) FGD-CA004 FGDC,E(L250) FGD-CA005 FGDC,E(L500) 7/11 FGX-OM-L007-C 2. 2.

FGD-KT002 FGDE Nut kit FGD-KT003 FGDT FGD-KT004 FGDF FGD-CV005-03 FGDT,F-03 FGD-CV005-04 FGDT,F-04 FGD-CV005-06 FGDT,F-06 Replacement cover (5) FGD-CV006-03 FGDC,E-03 FGD-CV006-04 FGDC,E-04 FGD-CV006-06 FGDC,E-06 Joint FGD-OP001 FGDB (10) KT-FGDC FGDC Each of (2)(4)(6)(13) and (16) are provided as a kit.

M Weight (g) AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 Model Applicable tubing O.D. d 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 27.9 28.2 29.6 32.4 40.2 32.5 33.1

04 0 5 VK Thread type Series VP 5 port solenoid valve Manifold Nil Rc VZ G F N NPT Base size NPTF T VF Common EXH 5 6 3 4 A/B Port size 1 VFR Symbol Port size 04 06 10 M Note) 1 Mixed VVP460 VVP450 1 2 3 4 VP4 Porting specifications Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Body size (Base size) 2 3 4 6 1/4 base 3/8 base 1/2 base 1 base Port size (Nominal size) 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Piping/Mounting Piping Note) Mounting method Body Panel mounting Body Panel mounting Symbol 0 1 2 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

N01 Connection NPT 1/8 N02 Connection NPT 1/4 Port size N03 Connection NPT 3/8 Option specifications Application Size Symbol N04 Connection NPT 1/2 IRV3000 IRV2000 IRV1000 F01 Connection G 1/8 01 02 03 04 1/8 1/4 3/8 1/2 F02 Connection G 1/4 F03 Connection G 3/8 F04 Connection G 1/2 Accessory (Option) Part No. Part no.