Electrical entry M M-type plug connector with lead wire (300 mm) MO M-type plug connector without connector Number of auto switches Nil S N 2 pcs. 1 pc. n pcs. Rated voltage 5 6 24 VDC 12 VDC For lead wire lengths other than 300 mm, refer to the plug connector lead wire (page 5). Applicable Auto Switches / Refer to pages 14 through to 16 for detailed auto switch specifications.
Nil Without auto switch (Built-in magnet) S 1 pc. 6 25 6 mm 25 mm For the applicable auto switch model, refer to the table below. n n pcs. 10 32 10 mm 32 mm 15 40 15 mm 40 mm Adjustment type 20 20 mm Nil With adjusting bolt B With shock absorbers (2 pcs.) Port thread type With shock absorber (With plate A) Installed on side A at time of shipment.
Communication protocol DN1 DN1-X26 MJ1 CS1 CS2 SL1 SL2 UW1 UH1 DeviceNet Note 1) DeviceNet Note 1) CC-Link OMRON Corp.: CompoBus/S (16 outputs) OMRON Corp.: CompoBus/S (8 outputs) SUNX Corp.: S-LINK (16 outputs) SUNX Corp.: S-LINK (8 outputs) NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System Note 1) DN1s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16
not use the S couplers with a leak tester or for vacuum retention because they are not guaranteed for zero leakage.
Free mount type Bearing type A High precision type Without auto switch 20 90 S M SUA 20 90 S D SUA L T79 M With auto switch Number of auto switches S Nil 1 pc. With auto switch (Built-in magnet) 2 pcs. S (1 auto switch) is shipped with a righthand auto switch. Nil (2 auto switches) is shipped with a right-hand and a left-hand switch.
D-X 709 ML2B Series Cylinder Specifications Bore size (mm) Fluid 25 32 40 Air Double acting Spring and pneumatic 0.1 to 0.8 MPa 0.3 to 0.5 MPa 1.2 MPa 0.75 MPa 5 to 60C (No freezing) 100 to 1500 mm/s (During the positioning 100 to 500 mm/s) Air cushion on both sides Non-lube 0 to 1.8 Action Cylinder Brake Operating pressure range Cylinder Brake Proof pressure Cylinder Brake Ambient and fluid
Example) -DNS All S kits are DIN rail mounting styles, so include suffix D. Specify the wring specifications in the manifold specification sheet. (Except L kit) F, P and S kits are provided with an exhaust on one side, while L kits are with an exhaust on both sides. Note 1) 01 1 station Note 2) The number of max. stations differs from kit to kit. (Refer to the table below.)
For vacuum equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www. smcworld.com ZU S 05 A Port size Nozzle diameter 05 0.5 mm 07 0.7 mm Nil 6 One-touch tting 01 Rc1/8 female thread Symbol EXH Vacuum pressure reached S 90 kPa L 48 kPa Mounting P V Caution Specications 1 .
RoHS Desktop Duster Box ZVB Series IZS How to Order IZN A S B ZVB 20 IZF ZVB ZVB q w e r t IZD IZE w Additional air blow B With additional air blow e Photoelectric sensor Nil None Note 1) S With photoelectric sensor Note 2) r AC adapter q Size Note 1) It is necessary to connect an external switch to the external input terminal on the back side of the product.
Body material: SUS304, Seal material: FKM, Non-greased specification (standard), Fluid: water, air, S COUPLER, S/S SPL, CONNECTORS, KKA S COUPLERS, PX, KKA THREADS ONLY, .05846 lb
(50 ms, 0.5 s, 2 s are selectable) Output protection Short circuit protection Output mode Hysteresis mode, window comparator mode, Accumulated output mode, Accumulated pulse output mode Hysteresis Variable Response time 1.5 s Voltage output Output voltage: 1 to 5 V Output impedance: 1 k Analogue output Output current: 4 to 20 mA Current output Max. load impedance: 600 (24 VDC) Min. load
The product has a fan(s) and could cause serious danger to operators. 8.2 Specifications Cool outlet air (10oC) can be supplied.
The product has a fan(s) and could cause serious danger to operators. 8.2 Specifications Cool outlet air (10oC) can be supplied.
Part number S coupler 11 KK4P-03MS for ordering a silencer alone is IBG1-12S. H06 6 KQ2H06-03AS H08 8 KQ2H08-03AS H10 10 KQ2H10-03AS H07 1/4" KQ2H07-36AS H09 5/16" KQ2H09-36AS H11 3/8" KQ2H11-36AS One-touch fitting * The S coupler or fitting is shipped together with the product. 3.
0.01 s increments Hysteresis Hysteresis mode Variable from 0 2 Window comparator mode Short circuit protection Provided Voltage output 3 Output voltage (Rated pressure range) Voltage output: 1 to 5 V2.5%F.S.
[s] [mm] [mm] 1.5 64 100 kPa 0.15 mm 2.0 64 100 kPa 0.3 mm [s] [s] [mm] [mm] -21No.PS-OMF0005CN-E ISA2-G ISA2-H 100 kPa 1.5 64 5 m 100 kPa 2.0 64 5 m [mm] [mm] [kPa] [kPa] -22No.PS-OMF0005CN-E ISA2 () 1 ON ( +)ON ()ON OFF Yes 2 No ( OFF +)ON 1 ()ON 3 ()ON 1,3 OFF 4 5 ON OFF 6 7 8 -23No.PS-OMF0005CN-E No.
~0.6Nm U +-( ) 1V ( ) +DIN
There are two decimal rotary switches for address setting; one for ten,s place and the other for unit,s. Setting range: 1 to 99 (10 dec.) Example: Example: 2 Address is set in network by using ET200 hand held unit or PG (programing tool). Once address is set, it is saved even if power is cut. Setting range: 1 to 125 (10 dec.) Value set on shipment: 125.
How to Order Standard L 40 150 CA2Y L Y7BW S 40 150 CDA2Y With auto switch Number of auto switches With auto switch (Built-in magnet) Nil S 3 n 2 pcs. 1 pc. 3 pcs. n pcs. Mounting B L F G C D T Basic Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion Auto switch Nil Without auto switch Please select the applicable auto switch model from the table below.
How to Order Standard L 25 100 CG1Y L H7BW S 25 100 CDG1Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.