LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
Bore Size: 10mm, Stroke: 6mm, Auto Switch: F8P--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire: Z (5m Lead Wire)
Body Class: 4 (ø10 Orifice), Valve Type: 0 (N.C.), Fitting Type: V (LQ1, Body Class: 2, 3, 4, 5, 6), Tube Size: 13 (1/2"), Output Tube Size: None, Pilot Connection: R (Thread Type 1/8 Rc), Pilot Port Direction: Direction 1, Option 1: 6 (High Back Pressure w/Flow Rate Adjustment)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 6
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 6
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 6
Size: 60, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Size: 20, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Size: 30, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Size: 40, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Size: 50, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Thread: N (NPT), Seal: S (Seal), Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Thread: R, Seal: S (Seal), Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Thread: N (NPT), Seal: None, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Thread: R, Seal: None, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Port Size: 5 (M5X0.8), Model: HL (Hose Elbow), Applicable Tube OD: 6 (Ø6XØ4)
Port Size: 5 (M5X0.8), Model: ALU (Barb Elbow for Soft Tubing), Applicable Tube OD: 6 (Ø6XØ4)
Port Size: 5 (M5X0.8), Model: AU (Barb Fitting for Soft Tubing), Applicable Tube OD: 6 (Ø6XØ4)