Refer to 4.3.2 Setting and checking,5.3.2 Setting and checking. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig 3.3-2 RS-232C connector connection 3.3 Connected explanation HRSH Series 3-2 HRX-OM-R028 Chapter 4 MODBUS communication function Chapter 4 MODBUS communication function MODBUS protocol is a communication protocol developed by Modicon.
a b c d e f g h i j k a ABS INC ABS() / / INC()// b c ) 0.5mm ()/ P.53 8.3 d e f )LEHZ(J)LEHFLEHS 40100% LEHZJ10L, LEHZJ16L 50100% g INP ON P.51 8.3 INP INP ON h 16 - )LEHZ(J)LEHS 550mm/secLEHF10 520mm/sec LEHF203240 530mm/sec /P.50,51 8.3 , i )150% P.52 8.3 j 2 AREA ON INC ABS() k () INP ON() )No.1 5 4 1( ) 17 - (1) a b c d e f g h i j k No.0 0 1<2 INP
A Input/output specifications 22 30 62 70 NPN open collector 2 output + Analog output Bracket D NPN open collector 2 output + Auto shift input Refer to the dimensions for the difference between brackets A and D. D PNP open collector 2 output + Analog output PNP open collector 2 output + Auto shift input Optional Note) Auto shift input is used for the auto shift function.
D-P3WA 56mm Nm D-M9(V) D-M9W(V) D-M9A(V) D-P3DWA 0.050.15 -12- (mm) L1 L2 L3 L4 L5 L6 16 5 MHM-16D 1 1 1 1 MHM-25D 36 34 MHM-32D 50 24 MHM-50D 23 25 80 41 / 3 NPN 3 PNP PLC PLC 2 2 PLC PLC PLC PLC -13- AND(),OR() *50ms 3 NPN OR 3 NPN AND 1 1 1 2 2 2 3 PNP AND 3 PNP OR 1 1 1 2 2 2 2 AND 2 OR 2 AND ON , 2 ON 20V 2 OR OFF OFF 1 1 ON 2 2 ON =-2 OFF =2 =1mA2 3k =6V 3k
This wiring is common in each mode. (1) Using 3-phase 200 V AC to 240 V AC power supply for LECSN2-T Note 1. Between P3 and P4 is connected by default. 2. Always connect between P+ and D terminals. (Factory-wired) 4.
Metal ( shaded) part Metal ( shaded) part Tap for ground wiring Resin part ( shaded) 454 Ionizer IZN10 Series Power Supply Cable Connection Circuit NPN PNP Ionizer Ionizer IZS Brown +24 VDC Brown +24 VDC +24 V +24 V Power supply 24 VDC 10% 0 V +24 V Power supply 24 VDC 10% 0 V +24 V Blue 0 V Blue 0 V IZN IZN INPUT PLC OUTPUT OUTPUT PLC INPUT IZF Orange Discharge stop signal Orange Discharge
(b) Incorrect mounting of V band (Not correctly fit with collar of cover) Fig. (b) Incorrect mounting of V-band [V-band for replacement] Part no: CY-27S Actuators Modular F.R.L. Pressure Control Equipment Retainer T bracket Caution Clean V-band and the contact surface between the cover and the case before mounting. Dirty contact surface lead to cause leakage.
(b) Incorrect mounting of V band (Not correctly fit with collar of cover) Fig. (b) Incorrect mounting of V-band [V-band for replacement] Part no: CY-27S Actuators Modular F.R.L. Pressure Control Equipment Retainer T bracket Caution Clean V-band and the contact surface between the cover and the case before mounting. Dirty contact surface lead to cause leakage.
[mm] (Reference value) 17 Weight 5.5 Most sensitive position [g] Auto switch model D-M9Nm-5 D-M9Pm-5 D-M9Bm-5 0.5 m (Nil) 7 6 Lead wire length 1 m (M) 13 11 3 m (L) 35 31 5 m (Z) 57 51 17-E683 D-M9m-5
AC (50/60 Hz) 100 V, 200 V, Other voltage (Option) 24 V, Other voltage (Option) 15% to +10% of rated voltage Class B or equivalent (130C) JIS Symbol PA DC Valve type Style N.C.
FH99-FL006-N V FH99-FL004-N V FH990-04 FH99-FL006-N V FH99-FL005-N V FH990-06 FH99-FL009-N V FH99-FL007-N V FH990-08 FH99-FL009-N V FH99-FL008-N V FH990-10 One set each of companion flange, seal, hexagon socket head cap screws FH99-FL011-N V FH99-FL010-N V w Operation The hydraulic fluid used becomes high viscosity when the temperature is low during the winter, etc., and the differential
Internal voltage drop: 1 V or less (With load current of 80 mA) PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (With load current of 80 mA) Switch output Note 4) Output specifications NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulse Pulse width: 50 msec Accumulated Note 4) pulse output Output voltage: 1 to 5 V; Load impedance:
circuit 0.35 (With light: 0.4) Power consumption (W) DC 0.1 (With light only) External pilot 1.4 (With light: 1.5) 100 V 110 V [115 V] 200 V SYJ31 R 2 4 SYJ32 R 2 4 1.6 (With light: 1.7) [1.7 (With light: 1.8)] (A) 2 (A) 2 Apparent power (VA) AC X X 2.3 (With light: 2.4) 220 V [230 V] 2.5 (With light: 2.6) [2.7 (With light: 2.8)] 1 (P) 3 (R) 1 (P) 3 (R) Surge voltage suppressor Indicator
H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5 to 50C (Air operated type: 60C) PA AC (50/60 Hz) DC VNC1 VNC Applicable pressure range 100 V, 200 V, Other voltage (Option) Coil rated voltage (V) 2 4 PAX 24 V, Other voltage (Option) 15% to +10% of rated voltage Class B or equivalent (130C) 1 4 VNC Allowable voltage fluctuation Coil insulation type Pressure VNC2 PB External
Pin description Load is an analog input equipment such as a voltmeter, ammeter. 1 DC(+) PF2A7H-(-M) 68 69 2 Analog output 3 DC() Accumulated pulse output wiring examples 4 OUT1 4-I thread with depth J 40 Max. 30 V 80 mA or less OUT1 Load Black H 0 V or Blue 50 msec 50 msec PF2A7H-(-M) 28 29 A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc1, NPT1, G1 36 M5 x
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols
Note Accessory/Option CB-50H Petroleum, Water-glycol, Emulsion Differential pressure indicator CB-50H-V Phosphoric ester CB-51H Petroleum, Water-glycol, Emulsion Differential pressure indication switch (N.C. and N.O. common) CB-51H-V Phosphoric ester AG-12H Petroleum Blanking cap (for differential pressure indication part) AG-12H-W Water-glycol, Emulsion AG-12H-V Phosphoric ester 517 A FH100
View port G1/2 Refer to page 529 for Microswitch for differential pressure indication switch. 523 FH150 Series Dimensions Differential pressure indication switch 62 Differential pressure indicator 16 (65) 29 A E F (34) 29 2 x Rc (d) J H 29 G OUT IN IN OUT Differential pressure indicator Differential pressure indication switch D (Element removal dimension) B C (mm) d A B C D E F G H J Weight