SMC Corporation of America
Elite Part Number Search
Search Results "VVEX2-1-7-02N"

] Element [Approx. 25] 24 + Stroke 18 + Stroke 11.5 + Stroke 3 Single acting Rod end male threads M4 x 0.7 Width across flats 7 Width across flats 4.5 M4 x 0.7 5 11h9 8.1 14.5 8.5 2.5 7 3.2 3.2 7 Rod end nut part no.: NTJ-010A 5 Series CUJ Dimensions (mm) 10 Double Acting/Single Acting 1in=25.4mm Without magnet/CUJB10 Note) The angular position of the width across flats is not fixed with

FH441-08 FH441-10 FH441-12 FH441-16 FH441-20 FH441-24 FH641-04 FH641-06 FH641-08 FH641-10 FH641-12 FH641-16 15 (1/2B) 15 (1/2B) 1/2 1/2 20 20 20 (3/4B) 20 (3/4B) 3/4 3/4 50 50 Max. 21 MPa 25 (1B) 25 (1B) 1 1 80 80 Max. 7 MPa 32 (1 1/4B) 32 (1 1/4B) 1 1/4 1 1/4 120 120 40 (1 1/2B) 40 (1 1/2B) 1 1/2 1 1/2 160 160 50 (2B) 50 (2B) 260 260 65 (2 1/2B) 450 80 (3B) 600 Note) Tapered female

VXA 8 15 5 VN M5,1/8 1 (IN) port M5,1/8 2 (N.C.) port 8.5 (6.3) LVC 6 12.8 LVA 1/8, 1/4 1/8, 1/4 2-M3 x 0.5 thread depth 5 1 (IN) port Dimensions inside ( ) are for port size 1/8. 2 (N.C.) port LVH LVD LVQ 2-M4 x 0.7 Thread depth 6 LQ LVN Bracket assembly part no.

(at 80 mA load current) Response time *5 *7 0.25 s/0.5 s/1 s/2 s/5 s Outputprotection Short circuit protection Output Mode Select from Hysteresis mode, Window comparator mode, Accumulated output mode or Accumulated pulse output mode Response time*6*7 0.25 s/0.5 s/1 s/2 s/5 s Analogue output Voltage output Output voltage: 1 to 5V (Output impedance approx. 1k) Current output Output current

/ Compliance Requirements . i 5 Chapter 1 Name of each Parts 1 1 Name of each Parts . 1 1 Chapter 2 Transportation / Installation 2 1 Transportation . 2 1 2 2 Installation . 2 1 2 2 1 Location . 2 1 2 2 2 Anchorage . 2 2 2 2 3 Air piping . 2 2 2 2 4 Electric wiring . 2 3 2 3 Cautions about Reinstallation . 2 5 Chapter 3 Operation / Shutdown 3 1 Check points before operation . 3 1 3 2 Operation

1 2 3 5 8 0 0 0 1 1 3 5 8 16 27 53 84 1 0 0 1 1 0 ZF ZP SP ZCUK Add or deduct the mass shown in the table on the left for order materials.

Connection thread 1/8 1/4 3/8 1/2 3/4 1 5.2 to 6.6 8.9 to 10.3 16.2 to 17.7 20.7 to 22.1 20.7 to 22.1 26.6 to 28.0 Installation and Adjustment Torque (7 to 9) (12 to 14) (22 to 24) (28 to 30) (28 to 30) (36 to 38) Warning Air Supply 1. Confirm the symbols 1 and 2 before the Warning valve is connected. The port marked 1 is the air inlet and the port marked 2 is the outlet.

(Space) A b C X y Z 0 1 2 7 8 9 / Press the button to move on to input the next digit. Press the and buttons simultaneously for 1 second or longer. : A dot cannot be displayed for the 6th digit. Perform the above button operation to remove a dot. Press the button for 1 second or longer to stop the flashing.

Max. 1 NL/min 10 NL/min PF2A710 3.5 CFM x 10-2 35.0 CFM x 10-2 5 NL/min 50 NL/min PF2A750 18 CFM x 10-2 176 CFM x 10-2 10 NL/min 100 NL/min PF2A711 3.5 CFM x 10-1 35.5 CFM x 10-1 20 NL/min 200 NL/min PF2A721 7 CFM x 10-1 71 CFM x 10-1 50 NL/min 500 NL/min PF2A751 18 CFM x 10-1 176 CFM x 10-1 : Analogue output is based on the rated flow range at normal condition.

) 3 7 52-SY7420-L-02 (-F2) 5 52.8 39.8 Insulation: Black () B 13.6 Manual override Insulation: Red (+) A 2 x 4.2 (Mounting holes for manifold) 20 42 2 x 1/4" {A (4), B (2) port} (52) (2 x 4.2 Mounting holes) 44 (For E type) 0.3 mm2 (42.5) (49.5) 40 40 24.5 14.7 1.55 (1.2) L 180.8 (Lead wire length) (14) 1/4" {P (1) port} 2 x 1/8" {EA (5), EB (3) port} 96.9 (23.9) 0.9 18 2 EB P EA 36 2 x 2.2

8" x 0.086" 1/8" TILMB01 1/8" x 1/16" 1/8" TILM05 3/16" x 1/8" 3/16" 4.75 1/8" 3.15 TILM07 1/4" x 5/32" 1/4" 6.35 5/32" 3.95 TILM11 3/8" x 1/4" 3/8" 9.53 1/4" 6.33 TILM13 1/2" x 3/8" 1/2" 12.7 3/8" 9.5 TILM19 3/4" x 5/8" 3/4" 19.05 5/8" 15.85 TILM25 1" x 7/8" 1" 25.4 7/8" 22.2 TILM32 11/4" x 11/10" 11/4" 31.75 11/10" 27.95 KQB2 O.D. 3.18 1/16" 1.58 0.086" 2.18 KS KX I.D.

This product process data consists of switch output status and position measurement value Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Description 1 Position measurement value (PD) BDC4 BDC3 BDC2 BDC1 1: BDC = Binary Data Channel The process data of this product is Big-Endian type.

4, G 1/4 NPT 1/4 Rc 1/4, G 1/4 NPT 1/4 Female thread Rc 1/4, G 1/4, NPT 1/4 Resin Case material Resin Aluminum Stainless steel Air (Nitrogen) Fluid 0.01 m (filtration efficiency: 99.99%) Note) Nominal filtration rating Initial pressure drop 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow) Maximum operating pressure (at 20C) 1.0 MPa (in case of nitrogen: 0.99 MPa) 5 to 45C Operating

ITVX Specifications PVQ VY1 SRH30 SRH40 SRH31 SRH41 Model Non-relief Relief Relief mechanism VBA VBAT Rc 1/8, 1/4 URJF 1/4 Rc 1/4, 3/8, 1/2 URJF 3/8 Rc 1/8, 1/4 Rc 1/4, 3/8, 1/2 Port size AP100 Grade A Clean air, N2, Ar, CO2, Pure water Clean air, N2 Fluid Grade B Air, N2, Ar, CO2, Water Air, N2 1.5 MPa Proof pressure 1 MPa Max. operating pressure Low pressure type High pressure type 0.02

7 9 SA 1 (P) VA 4 (B) 2 (A) 3 (R) 2 SA VA VH300/400 VM 8 5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 VR 4 3 VH 1 9 VHS 7 4 (B) 3 (R) 1 (P) 2 (A) 2 VH600 6 5 4 1 7 1 (P) 2 (A) 4 (B) 2 3 (R) Component Parts Material VH200/300/400 Zinc die-casted Aluminium die-casted

Default: Gain 9 Bit Bit 3, 2, 1, 0 Value 3 2 1 0 Setting Bit 0 0 0 0 Gain 0 0 0 0 1 Gain 1 0 0 1 0 Gain 2 0 0 1 1 Gain 3 0 1 0 0 Gain 4 0 1 0 1 Gain 5 0 1 1 0 Gain 6 0 1 1 1 Gain 7 1 0 0 0 Gain 8 1 0 0 1 Gain 9 1 0 1 0 Gain A 1 0 1 1 Gain B 1 1 0 0 Gain C 1 1 0 1 Gain D 1 1 1 0 Gain E 1 1 1 1 Gain F * indicates the initial shipping value. 3 Doc.No.DIT-69900-OM005-E Parameter index 0x43 Parameter

(For 20, 41, 42 and 45 Types) Pilot pressure range SS5YA Fill the same as SS5Y . 3 5 7 3 5 7 Pilot pressure MPa (Refer to Best Pneumatics No. 1-1.) Specify the part numbers for valves and options together beneath the manifold base part number. SS5YA5-42-03-02 1 set (Type 42, 3 station manifold base part no.) SYA5140 1 set (Single air operated valve part no.)

Specifications of temperature sensor Items Specifications Rated temperature range 0 to 100 oC 1 Analogue output accuracy 3% F.S. Response time 7 s 2 Ambient temperature characteristics 5% F.S. 1: The rated temperature range is of a single temperature sensor.

Return 0.5 0.4 0.2 0 0 Out -0.2 -0.4 -0.5 -0.6 -0.8 0 25 50 75 -1 1 2 3 4 -1 100 5 Input signal % F.S.

with the switch output)Voltage output: 1 to 5 V Output impedance: 1 k7Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDCVariableVoltage free input: 0.4 V or less (Reed or Solid state), input for 30 ms or longer2-screen display (Main screen: 4-digit, 7-segment, 2-color, Red/Green Sub screen: 6-digit, 11-segment, White)Output 1, Output 2: Orange12 to 24 VDC