Normal output Reversed output P_1 = A-(A-B)/4 n_1 = B+(A-B)/4 A = Max. pressure H_1 = (A-B)/2 H_1 = (A-B)/2 B = Min. pressure The set values of OUT2 become as follows "_", i.e. "P_2", "n_2" and "H_2".

Specifications 2. Installation and Handling P4 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Allowable kinetic energy 2-7. Control of direction 2-8. Auto switches 3. Maintenance P18 3-1. Replacement of rod seal 3-2. Checks 3-3. Consumable parts 4. Made to order product (XC85, X446) P21 4-1. Food Machinery Grease Specification 4-2.

Specifications 2. Installation and Handling P4 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Air cushion 2-7. Control of direction 2-8. Auto switches 3. Maintenance P19 3-1. Replacement of rod seal 3-2. Checks 3-3. Consumable parts 4. Made to order product (XC85, X446) P22 4-1. Food Machinery Grease Specification 4-2.

Note 4) Assembly of a bracket and set nuts Standard Specifications AWM20 AWD20 AWM30 AWD30 AWM40 AWD40 Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range 0.05 to 0.85 MPa Pressure gauge port size Note 1) 1/8 1/4 Ambient and fluid temperature Note 2) 5 to 60C (with no freezing) AWM20 to AWM40 0.3 m (95% filtered

Note 4) Assembly of a bracket and set nuts Standard Specifications AWM20 AWD20 AWM30 AWD30 AWM40 AWD40 Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range 0.05 to 0.85 MPa Pressure gauge port size Note 1) 1/8 1/4 Ambient and fluid temperature Note 2) 5 to 60C (with no freezing) AWM20 to AWM40 0.3 m (95% filtered

37 5200 R 1 1/2 9000 IDU55C 55 7650 50C R 2 12400 IDU75C 75 10500 35C 0.75 100 IDF1D 120 Series IDF Standard inlet air temperature type Rated temperature of 35 to 40C 1.5 200 IDF2D 235 Rc 3/8 2.2 300 IDF3D 350 R134a 9 to 12 40C 3.7 430 IDF4D 500 R 1/2 5.5 640 IDF6D 750 R 3/4 7.5 850 IDF8D 1000 1300 IDF11D R134a 11 R 3/4 1500 1300 IDF11C 15 2400 2050 IDF15C/15C1 R 1 22 3700 3150 IDF22C/22C1

RS Q G Oil draining hole Rc 1/4 Oil port size Rc RS H A (mm) Model Air port size Rc Oil port size Rc A B C DA DB DL H NL P QB QL S T W RZQ CCT633/8 3/4 104 88 64 86 88 53 45 28 3 86 30 0 11 9.5 MI W S CCT1001/2 1 139 125 92 116 123 61 65 33 5 120 32 2 13 7 CCT1603/4 1 1/4 202.5 185 144 180 183 60 93 29 0 185 46 2 20 7 CEP1 L Dimension CE1 (mm) 800 700 600 500 400 300 200 100 50 Effective

-260S ARP40P-260S G49-4-l01 G49-4-l02 0.4 MPa G49-2-l01 G49-2-l02 0.2 MPa Round type Note 2) G49-7-l01 G49-7-l02 0.7 MPa Pressure gauge ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output / Wiring bottom entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] NPN output / Wiring top entry Digital type Note 4) ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output / Wiring bottom

Warning Connection thread Proper tightening torque ( ( ( (N m) Rc1/8 3 to 5 Rc1/4 8 to12 Rc3/8 15 to 20 Rc1/2 20 to 25 Rc3/4 28 to 30 Rc1 36 to 38 Rc1 1/4 40 to 42 Rc1 1/2 48 to 50 Follow the procedure of the manufacturer when fittings other than SMC is used. 4. Piping Make P port piping so that supply air pressure does not become lower than operating pressure while operating.

Chamfer dimension D (Recommended value) (mm) M5 5.15.4 10-32UNF 5.05.3 Rc1/8 10.210.4 Rc1/4 13.613.8 Rc3/8 17.117.3 Rc1/2 21.421.6 NPTNPTF1/8 10.510.7 NPTNPTF1/4 14.114.3 NPTNPTF3/8 17.417.6 NPTNPTF1/2 21.721.9 Connection female thread size Connection thread size Proper tightening torque Nm G1/8 2.9 to 3.2 G1/4 5.7 to 6.3 G3/8 9.5 to 10.5 G1/2 14.3 to 15.8 8 - 2Specific Product Precautions6

M5 x 0.8 M4 x 0.7 NDh8 Z S 12-0.027 10-0.022 4 5 122 121 66 65 0 0 Foot (L): CJ2WL, CJ2WL 10112122View E Mounting nut Relief port 2 x M5 x 0.8 GA GA NN GC F MM NN GC F Rod end nut Cover surface Piping port 2 x M5 x 0.8 MM D D LY LB LH LZ LX LT LT Y NA X S + Stroke H NA Y A X 4 x LC Mounting hole A H + Stroke Z + 2 x Stroke C B 0 0.3 B 0 0.3 Drawing of view E (mm) Bore size 16 10 15 15 B LT

2 With external stopper/CRJU !3 !8 !4 !5 !8 !7 !

Dimensions inch (mm) AK3652 & 4652 1.50 (38) 2.17 (55) 2 x Compression 2 x R, NPT male 2 x Rc, NPT female 0.44 (11.2) B B A A A Connections: 4T, 6T Connections: N, BRN Connections: 4, 6, BR 4 6 4 6 4 6 25.4 45 Ports A B Connections inch (mm) inch (mm) 4T 2.56 (65.0) 1.12 sq. (28.4) 1/4 inch compression 4BR 1.70 (43.2) Rc 1/4 4BRN 2.32 (58.9) 1.12 sq. (28.4) R 1/4 4 1.70 (43.2) NPT 1/4

after R thread installation. 19.5 1 8 1 4 1 8 1 4 3 8 1 4 3 8 3 8 1 2 6 6.8 6.8 19 Width across flats 8 14 K 21.5 13.1 8 16.2 M5 x 0.8 17 Applicable tubing M 24 20.4 10 25.6 17 19 22 H 25.5 30.4 12 35.4 D MS Connection thread (With sealant) Male Elbow: KCL T H (width across flats) Applicable A M Effective area (mm 2) Nylon Urethane 1.9 1.9 6 11 7 13 21 16 24 37 29 38 63 81 Connection

Specifications 2. Operating method or operation 2-1. Design 2-2. Selection 2-3. Installation 2-4. Air supply 2-5. Piping 2-6. Operating environment 2-7. Lubrication 3. Maintenance 3-1. Precautions 3-2. Disassembly drawing 3-3. Finger assembly set replacement procedure 3-4. Seal replacement procedure 3-5.

Operating temperature (oC) 1 Fluoropolymer Tubing (PFA) Inch Size Series TILM RoHS Series Inch size Size Model Tubing size inch mm inch mm TILM01 1/8" x 0.086" 1/8" TILMB01 1/8" x 1/16" 1/8" TILM05 3/16" x 1/8" 3/16" 4.75 1/8" 3.15 TILM07 1/4" x 5/32" 1/4" 6.35 5/32" 3.95 TILM11 3/8" x 1/4" 3/8" 9.53 1/4" 6.33 TILM13 1/2" x 3/8" 1/2" 12.7 3/8" 9.5 TILM19 3/4" x 5/8" 3/4" 19.05 5/8" 15.85

-260S ARP40P-260S G49-4-l01 G49-4-l02 0.4 MPa G49-2-l01 G49-2-l02 0.2 MPa Round type Note 2) G49-7-l01 G49-7-l02 0.7 MPa Pressure gauge ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output / Wiring bottom entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] NPN output / Wiring top entry Digital type Note 4) ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output / Wiring bottom

However, it is constructed to be used for driving the product body, it may cause failure if it is used solely with a load applied. 2-4. Mounting and Installation 2-4-1. Mounting Surface It is recommended to mount the cylinder on a surface with a high flatness (e.g. a machined surface).

32 50 50 7 60 120 96 118 1 2, 3 4 82 68 88 92 1 181 53 12 81 70 35 36 66 52 9 66 140 96 133 DC C Model VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 A B Port size Rc 1 4, 3 8, 1 2 163 64 50.8 196 68 60.5 1 2, 3 4 4-16-7

(In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.) Note 6) The display unit is conformed to CE mark.