SMC Corporation of America
Elite Part Number Search
Search Results "JSXFH8-20N3-5PRB-S"

For opening the finger (O) Speed controller JAS-LEB04-M5 For closing the finger(S) Speed controller JAS-LEA04-M5 Hexagon socket head cap screwM4x20 5 - 3. Product Specifications 3-1. How to order JMHZ2 16 D M9B S X7500 A C KA Note2) For Kawasaki Heavy Industries, Ltd. Protection cover Number of auto switches Bore size[mm] Without protection cover With protection cover Nil.

How to order JMHZ2 16 D M9B S X7500 A C KR Number of fingers *Note 2) For KAWADA ROBOTICS CORPORATION 2 2 Number of auto switches Protection cover Bre bize[mm] Nil. Without protection cover Nil. 2 16 16mm C With proctection cover S 1 Action N n D Double acting Test attachment *Note1) Nil. Without attachment Auto switch A With attachment Auto switch No.

Pushing speed[mm/s] 20~30 10~30 5~30 2030 1030 2030 1030 actuator specification Max.acceleration/ 10 Horizontal Vertical 2] 5000 deceleration[mm/s Position repeatability [mm] 0.01 note4) 0.1 or less Lost motion [mm] Screw Lead [mm] 10 5 2.5 12 6 16 8 Impact / Vibration note5) 50/20 2] resistance [m/s Actuation type Ball screw (In-Line) Ball screw + Belt (Parallel) Guide type Linear guide

3-1 IDX-OM-W094 3.2 3.2.1 z (85%) z z z z z z 245 050 z z () z z z z z 2000m z z z 600 mm 600 mm 600 mm 600 mm 600 mm z z z 3.2.2 z z 7 7.3 z IDF-AB500 14 1 IDFA60/70/80/90 Series 3-2 IDX-OM-W094 3.2.3 z z z z z 60 z 65 65 z z z z z z z OUT IN (IN) (OUT) IN OUT IDFA60/70/80/90 Series 3-3 IDX-OM-W094 3.2.4 z 12mm 5m8mm z z z z SO O S

(Note 4)The F .S. means the condition at the maximum setting pressure of the product. (F .S. 0.2MPa, IR3000) (Note 5) Repeatability: This is the reproducibility of the downstream pressure at every operation (ON/OFF) on the downstream side.

Mount the marker (EX600-ZT1) into the marker groove as required. -14No.EX-OMS0027 SI Unit Model Indication and How to Order EX600-S EN 3 SI Unit Output type / Number of ports Symbol Content Protocol 3 PNP (negative common) / 2 port Symbol Content 4 NPN (positive common) / 2 port EN EtherNet/IPTM Summary of Product parts No.

S Short circuit detection Diagnostic function which detects generation of over current due to a short circuit between the output and the positive power supply line or the ground line. Short circuit protection Function which avoids damage to the internal circuit when over current is generated due to short circuit between the output and the positive power supply line or the ground line.

S Short circuit detection Diagnostic function which detects generation of over current due to a short circuit between the output and the positive power supply line or the ground line. Short circuit protection Function which avoids damage to the internal circuit when over current is generated due to short circuit between the output and the positive power supply line or the ground line.

Fork lever assembly M P368010-24 Fork lever assembly S P368010-25 Fig.21 Example of side attaching Fig.22 Example of backside attaching B using fork lever assembly M using fork lever assembly S 27 In the case of side attaching, if you use fork lever assembly M, it is compatible with our IP610 positioner in the attaching size.

S Set flow range The range of ON/OFF threshold values that can be set for products with a switch output. Reference condition for volumetric flow: 101.3 kPa, 20 C, 65%RH The flow measurement which is converted at normal atmospheric pressure conditions at 20 C, 65%R.H. Standard condition (ANR) An output type that has only 2 conditions, ON or OFF.

Diagnostics type 2 Table. 5-6 Overview of Diagnostics type 2 Byte Description 0 General diagnostics 1 1 Valve diagnostics 1 2 General diagnostics 2 3 Valve diagnostics 2 General diagnostics 1 Table. 5-7 General Diagnostics 1 Bit Description Explanation 0 Maximum number of valves 0: 16 Valves 1: 32 Valves or no "Valves" module 1 Valve coil(s) short circuit 0: No valve coil(s) have a short

Replacement part/Grease pack part no.: GR-S-010 (10 g) 15 - 3-6. Construction / Parts list, seal list MHZAJ2-6 Double acting/ Finger open Single acting / Normal open Single acting / Normal closed Double acting/ Finger closed Components Components No. Description Material Remarks No.

Time s 0.150.2 s Ex.) For DC24. DC6 V specification, The time to apply starting voltage is same for all voltage. 4-2 XLS-**-P*G (with control power supply) Valve (9) opens when the coil assembly is applied the rated voltage. Valve (9) closes when the coil assembly is stopped being energized.

Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) For instructions on how to replace replacement parts/seals, refer to the operation manual. 106

Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) For instructions on how to replace replacement parts/seals, refer to the operation manual. 108

Grease pack part number: GR-S-010 (10 g)/GR-S-020 (20 g) 7 Wide Type Parallel Style Air Gripper MHL2 Series Dimensions MHL2-10DmZ 6 6 9 2 x M4 x 0.7 thread depth 5 (Mounting thread) D Closed J View K (Fingers closed) The above figure shows the MHL2-10D1Z/10D2Z.

Z 5 16.5 10 25.5 5 29 10 38 Bore (mm) Stroke 2.5 Bore size: 4/CJ1B4-lSU4 Symbol S Z 5 19.5 10 28.5 15 37.5 20 46.5 5 40 10 49 15 58 20 67 Bore (mm) Stroke 4 1.1-5 World Wide QS\E Support...

Nil S Number of fingers 2 fingers Nominal size 2 10 15 20 30 Auto switch Nil Without auto switch (Built-in magnet) Connecting port For the applicable auto switch model, refer to the table below. R: Body side E: Axial side Port Port Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

HAl Accessories (Options) HAA7 AT Auto drain Applicable Model HAA7 HAA15 HAA22 HAA37 HAA7-F AD402-03 HAA7-S HAA15-F AD402-03 HAA15-S HAA22-F AD402-03 HAA22-S HAA37-F AD402-04 IDl Dust protecting filter Mounting bench HAA37-S AMG How to Select (Flow Capacity l/min (ANR)) Operation Principle AFF Model HAA7 HAA15 HAA22 HAA37 AMl 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000