(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E.
Fig. 8.4-1 Cooling capacity(HRSE012-A-10) 8.4.2 HRSE018-A-10-(T) 2000 2000 Ambient Ambient Temperature Temperature 25 25 1500 Cooling capacity[W] 1500 Cooling capacity[W] 35 35 1000 1000 500 500 0 0 0 10 20 30 40 0 10 20 30 40 Circurating fluid temperature[] Circurating fluid temperature[] 50Hz 60Hz The cooling capacity will be reduced by 100W when option: T is selected.
LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800
(mm) Shim thickness (mm) 0.3MPa 0.3MPa Recommended shim thickness Recommended shim thickness 0.5MPa 0.5MPa 0.7MPa 0.7MPa 8 - 63 Arm length L100mm Arm length L150mm 4000 4000 Peak clamping force position Peak clamping force position 3500 3500 3000 3000 0.7MPa 0.7MPa Clamping force (N) Clamping force (N) 2500 2500 2000 2000 0.5MPa 0.5MPa 1500 1500 0.3MPa 0.3MPa 1000 1000 500 500 0 0 0 0.5
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
Air filter (5 m or less) IR (Precision regulator) W D0.5 to 500 MQQL Anti-lateral load type (Built-in ball bushing) 0.005 to 0.7 When using a solenoid valve, use a metal seal type (Series VQ/VQZ/SQ, etc.).
light 8 3.2 DC (+) Brown 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 2.6 DC () Blue 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV Precautions OUT (+) Brown Be sure to read before handling.
Superior relief flow characteristics Relief flow has been increased by nearly 5 times (compared to SMC IR201, IR401) Conditions: Back pressure 0.7MPa Conditions: Back pressure 0.7MPa 0.7 IR3010 0.7 IR2010 IR201 0.6 0.6 IR401 Set pressure MPa Set pressure MPa 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 1000 0 5000 4000 3000 2000 600 500 400 300 200 100 0 Relief flow l/min (ANR) Relief flow l/min
Count Pressure characteristics Flow characteristics Supply pressure: 0.2MPa Set pressure: 0.05MPa Relief flow characteristics Supply pressure: 0.2MPa 0.25 1.0 0.15 Output deviation factor (%F.S.) 0.20 0.5 Set pressure (MPa) Set pressure (MPa) 0.10 Set point 0.15 0.0 0.10 0.05 0.5 0.05 1.0 0 500 1000 1500 2000 0.00 0.00 0 500 1000 2000 1500 0.0 0.1 0.2 0.3 Flow rate (l/min (ANR)) Flow rate
1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
100 200 300 400 600 500 100 200 300 400 600 Load (N) Load (N) Load (N) 8-7-5 6 Long Stroke Slide Table Series MXW 8, 12, 16, 20, 25 How to Order MXW 16 100 B M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.
TU0425G-500-X3 20 m roll Inch size: Suffix -X4 to the end of part number. Ex.) TIUB01W-20-X4 Made to Order Availability Length Model Part no.
TS0425G-500-X3 20 m roll Inch size: Suffix -X4 to the end of part number. Ex.) TISA01BU-20-X4 Made to Order Availability Length Model Part no.
Rc1/8 Port X (PE) 2 position/Double : VQ7-6-FG-D-SC Double (reverse pressure): VQ7-6-YZ-D-SC 3 position/Closed center : VQ7-6-FHG-D-SC Exhaust center : VQ7-6-FJG-D-SC Pressure center : VQ7-6-FIG-D-SC 145 86.5 155 68.5 76.5 50 50 68.5 50 50 Manual override 13 (port A) 13 (port B) Manual override 13 (port A) 13 (port B) B A B A 62 38 50 38 50 62 A B A B Prewired connector (M12) (L approx. 500
1.7 45 or less 47 or less Metal seal VQC4400 Exhaust center 280 7.0 7.3 0.38 1.9 0.38 2.0 50 or less 52 or less Rubber seal VQC4401 6.2 6.4 0.18 1.9 0.18 1.6 45 or less 47 or less Metal seal VQC4500 Pressure center 1 (P) 5 (R1) 3 (R2) 7.0 7.1 0.38 1.9 0.38 2.0 50 or less 52 or less Rubber seal VQC4501 3-position perfect 2.7 3.7 55 or less 57 or less Metal seal VQC4600 (A) 4 (B) 2 Perfect 500
Insulation resistance Between external terminal batch and case: 2 M (at 500 VDC) 2 hrs. each in X, Y, Z directions at smaller of 10 to 500 Hz with amplitude 1.5 mm, or acceleration 10 G Vibration resistance Impact resistance 100 G in X, Y, Z directions, 3 times each Note) Not available on analog output type.
If the adjusting screw of the speed controller is loosened, the operating speed will increase, so the screw should be tightened completely. m Impact force MXZ12 MXZ16 1.4 2.5 V = mm/s V = mm/s 1.2 2.0 Load weight m [kg] Load weight m [kg] 1.0 1.5 0.8 0.6 1.0 V = 50 V = 50 0.4 V = 100 V = 100 V = 200 V = 200 0.5 V = 500 V = 500 0.2 0.0 0.0 60 50 40 30 20 10 0 0 5 20 15 10 25 30 35 40 45 50
Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.
Impedance [] [Unit: mm] 10 MHz to 100 MHz 100 MHz to 500 MHz 39 1 80 150 Loop for fixing the cable band 34 1 13 1 TDK 30 1 Lot number Product name Outline drawing (ZCAT3035-1330) (b) Surge killer (recommended) Use of a surge killer is recommended for AC relay, magnetic contactor or the like near the driver. Use the following surge killer or equivalent.
X576 X577 X578 X579 X580 Applicable fluid Air, non-corrosive gas and non-flammable gas Rated pressure range -500 to 500 Pa -1.000 to -2.00 to -5.00 to -10.00 to Pressure spec. 1.000 kPa 2.00 kPa 5.00 kPa 10.00 kPa Display/Set pressure range -525 to 525 Pa -1.050 to -2.10 to -5.25 to -10.50 to 1.050 kPa 2.10 kPa 5.25 kPa 10.50 kPa Display/Min. setting unit 1 Pa 0.001 kPa 0.01 kPa 0.01 kPa