Flow Rate: 7 CFM / 12 m3/hr / 198 LPM , 7 CFM / 12 m3/hr / 198 LPM, Max Pressure: 11.6 PSIG / .8 bar , 11.6 PSIG / .8 bar, Horsepower (60 Hz): .59, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Net Weight: 22.7 lbs. / 10.3 Kg Series Configured Datasheet.

Flow Rate: 2.4 CFM / 4.2 m3/hr / 68 LPM , 2.4 CFM / 4.2 m3/hr / 68 LPM, Max Pressure: 14.5 PSIG / 1 bar , 14.5 PSIG / 1 bar, Horsepower (60 Hz): .19, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Net Weight: 14.3 lbs. / 6.5 Kg Series Configured Datasheet.

Flow Rate: 4.2 CFM / 7.2 m3/hr / 119 LPM , 4.2 CFM / 7.2 m3/hr / 119 LPM, Max Pressure: 14.5 PSIG / 1 bar , 14.5 PSIG / 1 bar, Horsepower (60 Hz): .4, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.66 in / 220 mm Width: 5.98 in / 152 mm Height: 6.14 in / 156 mm , Length: 8.66 in / 220 mm,

Body Style: B (Base Mounted w/Screws), Coil Voltage: S (5 VDC), Flow Rate: D (Power Consumption: 0.5W, Operating Press: 0.5MPa, Cv: 0.011), Electrical Entry: G (Grommet), Port Size: w/o Sub-plate, Made to Order: X26 (Special Lead Wire Length), Lead Wire Length: 3 (300 mm)

Body Style: B (Base Mounted w/Screws), Coil Voltage: 6 (12 VDC), Flow Rate: C (Power Consumption: 0.5W, Operating Press: 0.3MPa, Cv: 0.016), Electrical Entry: C (Plug Lead w/Light/Surge Suppressor), Port Size: M5 (Base Mounted, w/Sub-plate), Made to Order: X50 (Universal Type)

Body Style: B (Base Mounted w/Screws), Coil Voltage: 5 (24VDC), Flow Rate: B (Power Consumption: 0.35W, Operating Press: 0.3MPa, Cv: 0.011), Electrical Entry: C (Plug Lead w/Light/Surge Suppressor), Port Size: M5 (Base Mounted, w/Sub-plate), Made to Order: X50 (Universal Type)

Body Style: B (Base Mounted w/Screws), Coil Voltage: S (5 VDC), Flow Rate: A (Power Consumption: 0.35W, Operating Press: 0.1MPa, Cv: 0.016), Electrical Entry: G (Grommet), Port Size: M5 (Base Mounted, w/Sub-plate), Made to Order: X50 (Universal Type)

Body Style: B (Base Mounted w/Screws), Coil Voltage: 5 (24VDC), Flow Rate: D (Power Consumption: 0.5W, Operating Press: 0.5MPa, Cv: 0.011), Electrical Entry: G (Grommet), Port Size: M5 (Base Mounted, w/Sub-plate), Made to Order: X50 (Universal Type)

Body Style: B (Base Mounted w/Screws), Coil Voltage: 6 (12 VDC), Flow Rate: B (Power Consumption: 0.35W, Operating Press: 0.3MPa, Cv: 0.011), Electrical Entry: G (Grommet), Port Size: w/o Sub-plate, Made to Order: X26 (Special Lead Wire Length), Lead Wire Length: 6 (600 mm)

Body Style: Base Mounted w/Screws, Coil Voltage: 5 VDC, Flow Rate: Power Consumption: 0.5W, Operating Press: 0.5MPa, Cv: 0.011, Electrical Entry: Grommet, Port Size: w/o Sub-plate, Made to Order: Special Lead Wire Length, Lead Wire Length: 300 mm

Body Style: Base Mounted w/Screws, Coil Voltage: 12 VDC, Flow Rate: Power Consumption: 0.5W, Operating Press: 0.3MPa, Cv: 0.016, Electrical Entry: Plug Lead w/Light/Surge Suppressor, Port Size: Base Mounted, w/Sub-plate, Made to Order: Universal Type, Lead Wire Length: -

Body Style: Base Mounted w/Screws, Coil Voltage: 24VDC, Flow Rate: Power Consumption: 0.35W, Operating Press: 0.3MPa, Cv: 0.011, Electrical Entry: Plug Lead w/Light/Surge Suppressor, Port Size: Base Mounted, w/Sub-plate, Made to Order: Universal Type, Lead Wire Length: -

Body Style: Base Mounted w/Screws, Coil Voltage: 5 VDC, Flow Rate: Power Consumption: 0.35W, Operating Press: 0.1MPa, Cv: 0.016, Electrical Entry: Grommet, Port Size: Base Mounted, w/Sub-plate, Made to Order: Universal Type, Lead Wire Length: -

Body Style: Base Mounted w/Screws, Coil Voltage: 24VDC, Flow Rate: Power Consumption: 0.5W, Operating Press: 0.5MPa, Cv: 0.011, Electrical Entry: Grommet, Port Size: Base Mounted, w/Sub-plate, Made to Order: Universal Type, Lead Wire Length: -

Body Style: Base Mounted w/Screws, Coil Voltage: 12 VDC, Flow Rate: Power Consumption: 0.35W, Operating Press: 0.3MPa, Cv: 0.011, Electrical Entry: Grommet, Port Size: w/o Sub-plate, Made to Order: Special Lead Wire Length, Lead Wire Length: 600 mm

Series S070 is a super compact direct acting 2/3 port solenoid valve that meets the miniaturization needs of analyzers, medical equipment and semiconductor manufacturing equipment. S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base). Valve width is 7mm. 3 port solenoid

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, BASE MOUNT W/SUB-PLATE, VALVE, S070 SOLENOID VALVE,3-PORT, MI, S070 BASE MOUNT M5), 8.28570 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, BASE MOUNT W/SUB-PLATE, VALVE, S070 SOLENOID VALVE,3-PORT, MI, S070 BASE MOUNT M5), .40097 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, BASE MOUNT W/SUB-PLATE, VALVE, S070 SOLENOID VALVE,3-PORT, MI, S070 BASE MOUNT M5), .09446 lb