. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)
Model: 10 (Side Ported), Number of Cores - Lead Wires: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 3 Stations, P, E Port Locations: U (U Side), SUP/EXH Block: S (Internal Pilot/Built-in Silencer), A, B Port Size: C8 (ø8 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 0 (w/o DIN Rail with Bracket)
Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)
Model: 10 (Side Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 7 Stations, P,E Port Entry: B (Both Sides, 2 to 24 Stations), SUP/EXH Block Assembly: Internal Pilot, A,B Port Size: N11 (ø3/8" One-touch Fitting, Straight, Inch)
Body Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V
Series: 3 (JSY3000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 3 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only)
Part Number Description: FLANGE MTG KIT Product Line: A Product Line Description: ACTUATOR Family Code: 516 Family Description: NCQ2 COMPACT CYLINDER Class Code: L2 Part Code: 2 Reference Code: E This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
Part Number Description: FLANGE Product Line: A Product Line Description: ACTUATOR Family Code: 420 Family Description: CG ROUND BODY CYLINDER Class Code: L2 Part Code: 2 Reference Code: E This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
Model: 10 (Side Ported), Number of Cores - Lead Wires: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 8 Stations, P, E Port Locations: B (Both Sides), SUP/EXH Block: S (Internal Pilot/Built-in Silencer), A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
Series: 3 (JSY3000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 6 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment